CY24272
Document Number: 001-42414 Rev. **
Page 5 of 13
Note
5. RW = Read and Write, RO = Read Only, POD = Power on default. See
Table 3
on page 3 for PLL multipliers and
Table 5
on page 4 for clock output selections.
Table 6. Command Code 80h
[5]
Bit
Register
POD
Type
Description
7
Reserved
0
RW
Reserved (no internal function)
6
MULT2
0
RW
PLL Multiplier Select (reference
Table 3
on page 3)
5
MULT1
0
RW
4
MULT0
1
RW
3
RegA
1
RW
Clock 0 Output Select
2
RegB
1
RW
Clock 1 Output Select
1
RegC
1
RW
Clock 2 Output Select
0
RegD
1
RW
Clock 3 Output Select
Table 7. Command Code 81h
[5]
Bit
Register
POD
Type
Description
7
Reserved
0
RW
Reserved (no internal function)
6
Reserved
0
RW
5
Reserved
0
RW
4
Reserved
0
RW
3
Reserved
1
RW
Reserved (must be set to ‘1’ for proper operation)
2
REFSEL
0
RW
Reference Frequency Select (reference
Table 3
on page 3)
1
Reserved
0
RW
Reserved (must be set to ‘0’ for proper operation)
0
RegTest
0
RW
Reserved (must be set to ‘0’ for proper operation)
Table 8. Command Code 82h
[5]
Bit
Register
POD
Type
Description
7
Device
Revision
Number
?
RO
Contact factory for Device Revision Number information.
6
?
RO
5
?
RO
4
?
RO
3
?
RO
2
Vendor ID
0
RO
Rambus assigned Vendor ID Code
1
1
RO
0
0
RO