3.3V TAP AC Test Conditions
Input pulse levels ............................................... V
SS
to 3.3V
Input rise and fall times ...................... ..............................1ns
Input timing reference levels ...........................................1.5V
Output reference levels...................................................1.5V
Test load termination supply voltage ...............................1.5V
3.3V TAP AC Output Load Equivalent
2.5V TAP AC Test Conditions
Input pulse levels................................................ .V
SS
to 2.5V
Input rise and fall time .....................................................1 ns
Input timing reference levels................... ......................1.25V
Output reference levels .................. ..............................1.25V
Test load termination supply voltage .................... ........1.25V
2.5V TAP AC Output Load Equivalent
Notes:
10. t
CS
and t
CH
refer to the set-up and hold time requirements of latching data from the boundary scan register.
11. Test conditions are specified using the load in TAP AC test Conditions. t
R
/t
F
= 1 ns.
TAP AC Switching Characteristics
Over the operating Range
[10, 11]
Parameter
Description
Min.
Max.
Unit
Clock
t
TCYC
TCK Clock Cycle Time
50
ns
t
TF
TCK Clock Frequency
20
MHz
t
TH
TCK Clock HIGH time
20
ns
t
TL
TCK Clock LOW time
20
ns
Output Times
t
TDOV
TCK Clock LOW to TDO Valid
10
ns
t
TDOX
TCK Clock LOW to TDO Invalid
0
ns
Set-up Times
t
TMSS
TMS Set-up to TCK Clock Rise
5
ns
t
TDIS
TDI Set-up to TCK Clock Rise
5
ns
t
CS
Capture Set-up to TCK Rise
5
ns
Hold Times
t
TMSH
TMS Hold after TCK Clock Rise
5
ns
t
TDIH
TDI Hold after Clock Rise
5
ns
t
CH
Capture Hold after Clock Rise
5
ns
TDO
1.5V
20pF
Z = 50
Ω
O
50
Ω
TDO
1.25V
20pF
Z = 50
Ω
O
50
Ω
[+] Feedback