COMMAND
Description and Parameters
Serial Commands
set uart N1 N2
Enable or disable the RS-232 pass-through function for the specified HDBa-
seT output or the local port.
Available values for
N1
:
A
[Output
A]
B
[Output
B]
C
[Output
C]
D
[Output
D]
E
[Local
RS-232]
Available values for
N2
:
ON
[Enable
RS-232
pass-through]
OFF
[Disable
RS-232
pass-through]
get uart
N1
Show the current RS-232 pass-through setting for the specified port.
Available values for
N1
:
A
[Output
A]
B
[Output
B]
C
[Output
C]
D
[Output
D]
E
[Local
RS-232]
set uart N1 baud rate N2
Set the baud rate of the specified RS-232 port.
Available values for
N1
:
A
[Output
A]
B
[Output
B]
C
[Output
C]
D
[Output
D]
E
[Local
RS-232]