![CYP MOD-32 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/cyp/mod-32/mod-32_operation-manual_2705016009.webp)
9
B. IP Settings
1. IP address
2. IP Netmask
3. IP Gateway
Note: For display only, these values can only be changed in the Web GUI
or via RS-232/Telnet
C. Temperature
1. Temperature 1
2. Temperature 2
NOTE: these figures show the internal temperature of the device.
D. LCM Contrast Range from 1~4
6
ALL:
Press this button to assign the same input to all outputs.
7
0~9:
Use to select the appropriate numbered input or output.
8
OUT/IN:
Press to assign the source to be displayed on the required
output. The sequence should be OUT/IN
→
Select the Input
→
OUT/
IN
→
Select the output
→
Enter.
9
+ (Plus):
Press this button when multiple outputs are required for a
selected input. This button only works in conjunction with the OUT/IN
button.
10
LOCK button & LED:
Press this button to lock all the function buttons
on panel. The LED will illuminate, to unlock press it again.
11
SAVE:
Press this button to store the present Input/Output
configuration to one of the 8 available preset settings.
12
RECALL:
Press this button to recall a previously stored preset setting.
13
ENTER:
Press this button to confirm a setting or selection in the menu.