6.6 WebGUI Control
On a PC/Laptop that is connected to an active network system, open
a web browser and type device’s IP address on the web address entry
bar. A security page will appear to ask for User and Password, please
key in “admin” for both to enter.
Note: The Default IP setting is on Static with address at 192.168.1.50.
The browser will display the device’s Macro Setting, Extension Macro,
Command Settings, Schedule, Network and System Settings pages for
users to control.
6.6.1 Macro Settings
The Background Light Bar allows user with instant change on the LEDs
lighting percertanage base on the orignial illuminate setting.
There are 6 Macro inserted as default setting for testing the Wall-Plate
Control System’s functionality. Click on Macro 1~6 to demonstrate the
function of lighting LEDs.
• Macro 1: Light up the Red backlight LED with 100% brightness
sequentially from 1~8 with every 500ms.
• Macro 2: Light up the Blue backlight LED with 100% brightness
sequentially from 1~8 with every 500ms.
• Macro 3: Switch off all the read backlight LED with 0% brightness.
• Marco 4: Switch off all the blue backlight LED with 0% brightness.
• Marco 5: LED show mode toggle, swith off Demo Mode
• Macro 6: Light up the Blue backlight LED with 10% brightness, Switch
off all the blue backlight LED with 0% brightness, switch Off & On
Relay 1 with delay of 1000ms.
To disable default testing mode, click on Demo Mode/Marco 5 to
swith it off.