6.6 RS-232 and Telnet Commands

COMMAND

DESCRIPTION

PARAMETER

HELP (?)

Show Command List

NONE

HELP N

Show Descript Of 

Command

N=COMMAND NAME

P0

Power Off (Standby)

NONE

P1

Power On

NONE

MUTE

Show AMP Mute Mode

NONE

MUTE N

Set AMP Mute Mode N

N=0 (UNMUTE), 1 (MUTE)

SPEAKER

Show Speaker Input Source

NONE

SPEAKER N

Set Speaker Input Source

N=0 (HDMI), 

1=(OPTICAL)

AUDIOFMT

Show EDID Audio Format

NONE

AUDIOFMT N

Set EDID Audio Format N

N=0 (PCM), 1 (BYPASS)

SOUNDSYS

Show AMP Sound System

NONE

SOUNDSYS N

Set AMP Sound System N

N=0 (STEREO), 1 (MONO)

VOL

Show AMP Volume

NONE

VOL N

Set AMP Volume N

N=0-100

A N

Select Input N

N=1-4*

IPCONFIG

Display The Current IP 

Configure

NONE

SIPADDR XXX.XXX.

XXX.XXX

Set Ethernet IP Address

XXX=0~255

SNETMASK XXX.XXX.

XXX.XXX

Set Ethernet Net Mask

XXX=0~255

SGATEWAY XXX.XXX.

XXX.XXX

Set Ethernet Gateway

XXX=0~255

HTTPPORT N

Set Http Port Number

N=0~65535

RSTIP

IP Configuration Reset To 

<DHCP>

NONE

EDIDMODE

Show EDID Mode

NONE

EDIDMODE N

Set EDID Mode

N=0 (Appoint), 1 (All)

Содержание CDPS-UH4H1HFS

Страница 1: ...D R A F T CDPS UH4H1HFS 4 By 1 HDMI UHD Switcher with Fast Switching and Control System Operation Manual Operation Manual ...

Страница 2: ...D R A F T ...

Страница 3: ...gy reserves the right to make improvements to this document and or product at any time and without notice COPYRIGHT NOTICE No part of this document may be reproduced transmitted transcribed stored in a retrieval system or any of its part translated into any language or computer file in any form or by any means electronic mechanical magnetic optical chemical manual or otherwise without express writ...

Страница 4: ... Never push an object of any kind into this product through any openings or empty slots in the unit as you may damage parts inside the unit Do not attach the power supply cabling to building surfaces Use only the supplied power supply unit PSU Do not use the PSU if it is damaged Do not allow anything to rest on the power cabling or allow any weight to be placed upon it or any person walk on it To ...

Страница 5: ... 2 Rear Panel 5 6 3 Remote Control 6 6 4 IR Cable Pin Assignment 7 6 5 RS 232 Protocol 7 6 6 RS 232 and Telnet Commands 8 6 7 Software Application 13 6 8 Telnet Control 14 6 9 WebGUI Control 16 7 Connection Diagram 20 8 Specifications 21 8 1 Technical Specifications 21 8 2 Supported Resolutions 22 8 3 Supported Audio Formats 23 8 4 Audio Performance 23 9 Acronyms 24 ...

Страница 6: ...over devices The operation of the system can be easily managed through software application on PC Laptop or APP on mobile devices on panel buttons IR remote control RS 232 Telnet or Ethernet protocols 2 APPLICATIONS Home entertainment security control Showroom display control Educational demo control 3 PACKAGE CONTENTS 1 4 By 1 HDMI Matrix with Fast Switch Control System 1 IR Blaster 1 3 5mm phone...

Страница 7: ...ous audio outputs on both HDMI and analog R L HDMI inputs support Standard and Apple HDCP modes Selecting Apple mode guarantees the compatibility of Apple devices Support RS 232 IR Telnet and WebGUI controls Supports four inputs control with voltage of 0 3 3v Supports control system with 5 IR outputs 4 Trigger inputs 4 Relay outputs and 2 COM ports Supports COM port s Baud rate from 4800 115200bps...

Страница 8: ...N and the LED will blink once 2 IR Window and LED This IR Receiver receives the remote control signal from the package included remote control only and the LED will blink when IR signal is receiving 3 OPTICAL IN Button and LED Press this button to select output audio from optical source and the LED will illuminate 4 HDMI IN Button and LEDs 1 4 Press this button to select an input from the input so...

Страница 9: ...nking Press it again to unmute and the LED will switch off Note For restore back to factory default press and hold this button then plug in the AC power into the device 7 SYNC LED This LED will illuminate when the input detected HDMI signal from source equipment 8 TRIGGER IN LED 1 4 These LEDs will illuminate when IN connection obtain active low DC voltage of 0 0 5V which is also when signals has ...

Страница 10: ...HDMI equipped source device for input signal sending This device has source auto detection function from the latest input and when the latest input has been pulled out it will follow the number sequence 6 HDMI OUT Connect to HDMI TV display or HD Amplifier for output image and or audio display 7 OPT IN This slot is to connect with audio source equipment such as Blu ray PS3 player for audio signal ...

Страница 11: ...and connect to AC wall outlet for power supply 6 3 Remote Control 1 POWER Press this button to switch On or set the device to standby mode 2 INPUT 1 4 Press these buttons once a time to select or switch input source 3 MUTE Press this button to mute the SPEAKER output sound press it again to unmute 4 OPTICAL Press this button to select audio from optical input source 5 VOL Press these buttons to mo...

Страница 12: ...wer IR Signal NC 6 5 RS 232 Protocol SWITCHER REMOTE CONTROLLER Pin Assignment Pin Assignment 1 NC 1 NC 2 TxD 2 RxD 3 RxD 3 TxD 4 NC 4 NC 5 GND 5 GND 6 NC 6 NC 7 NC 7 NC 8 NC 8 NC 9 NC 9 NC Baud Rate 115200bps Data bit 8 bits Parity None Flow Control None Stop Bit 1 ...

Страница 13: ... AUDIOFMT N Set EDID Audio Format N N 0 PCM 1 BYPASS SOUNDSYS Show AMP Sound System NONE SOUNDSYS N Set AMP Sound System N N 0 STEREO 1 MONO VOL Show AMP Volume NONE VOL N Set AMP Volume N N 0 100 A N Select Input N N 1 4 IPCONFIG Display The Current IP Configure NONE SIPADDR XXX XXX XXX XXX Set Ethernet IP Address XXX 0 255 SNETMASK XXX XXX XXX XXX Set Ethernet Net Mask XXX 0 255 SGATEWAY XXX XXX...

Страница 14: ...tus N1 1 4 HDCPIN N1 N2 Set Input N1 HDCP On Off N1 1 4 N2 0 OFF 1 ON SOURCEDET Show All Inputs Signal NONE SOURCEDET N1 Show Input N1 Signal N1 1 4 SINKINFO Show Output Information NONE INNAME Show All Inputs Name NONE INNAME N1 Show Input N1 Name N1 1 4 INNAME N1 N2 Set Input N1 Name N1 1 4 N2 ABCDEFGH Max Length 8 OUTNAME Show Output Name NONE OUTNAME A N1 Set HDMI Output Name N1 ABCDEFGH Max L...

Страница 15: ...E SET CONDITION OF TRIGGER EVENT N1 PORT 1 4 N2 STATUS NONE INFO NONE ACTIVE DISABLED ENABLED MODE RAISING EVENT ACTIVE WHEN TER MINAL BLOCK PORT STATUS FROM LOW TO HIGH FALLING EVENT ACTIVE WHEN TERMINAL BLOCK PORT STATUS FROM HIGH TO LOW CHANGE EVENT ACTIVE WHEN TERMINAL BLOCK PORT STATUS IN RAISING OR FALLING COMSEND N N1 N2 SEND COMMAND TO COM PORT COMSEND N N1 N2 N LOCATION COM N1 PORT 1 2 N2...

Страница 16: ...TE 4800 9600 19200 38400 57600 115200 N3 DATA LEN 5 6 7 8 N4 PARITY 0 NONE 1 ODD 2 EVEN N5 STOP BIT 1 2 CMDTBL SHOW N Show Command list N CMD ID 1 128 CMDTBL ADD N N1 Add Command N CMD ID 1 128 N1 DATA CHARACTERS 1 512 CMDTBL DEL N Delete Command N CMD ID 1 128 CMDTBL Name N N1 Name Command N CMD ID 1 128 N1 CMD NAME 0 24 characters including space MACRO MACRO CONTROL MACRO SHOW N N1 Show Macro N ...

Страница 17: ...MACRO RUN N MACRO CONTROL VER Show Unit Firmware Version NONE REBOOT System Reboot NONE FADEFAULT All Configure Set To Factory Default NONE HDMI input port 1 4 Internal EDID selection 1 9 Deep color 2D3D audio resolution 1 HDMI output native 2 8 2D PCM 720p 3 8 2D PCM AC3 720p 4 8 2D PCM 1080p 5 8 2D PCM AC3 1080p 6 8 2D PCM 4K2K 7 8 2D PCM AC3 4K2K 8 8 2D Y420 9 8 2D AC3 Y420 Note 1 Any commands ...

Страница 18: ...Control System with an active network system and open the CDPS V2 000 application from the directory in a PC Laptop Click on Find Devices on Network and a list of the devices connected to the Control System will show up Double click on the product name and an InfoFrom will appear to show the products detail Then user may use the IP Address to find the control device through Telnet Web GUI or even ...

Страница 19: ...md in the Search field then press enter Under Windows XP go to the Start menu and click on Run type cmd with then press enter Under Mac OS X go to Go Applications Utilities Terminal See below for reference Once in the command line interface CLI type telnet then the IP address of the unit and 23 then hit enter ...

Страница 20: ...e wish to control Type help to list the available commands Note Commands will not be executed unless followed by a carriage return Commands are case sensitive If the IP is changed then the IP Address required for Telnet access will also change accordingly ...

Страница 21: ...P 192 168 1 50 on the web address entry bar A security page will appear to ask for User and Password please key in Admin for both and click Submit to enter The browser will display device s Routing Audio EDID Macro Command Network System Settings control pages for users to control Click on Routing to view current connection status and rename input and output ...

Страница 22: ...D R A F T 17 Click on Audio to adjust audio format sound system speaker mode and volume Click on EDID to select EDID setting on all inputs or appoint input s ...

Страница 23: ...D R A F T 18 Click on Macro Settings to insert up to 16 commands into a Macro button Click on Command Settings to edit or remove the commands up to 128 sets ...

Страница 24: ...P configuration Once the changes are saved the system will reset the IP address on device automatically and user will need to re enter the IP address to continue the WebGUI control Click on System Settings to trigger device power or reset the settings back to default ...

Страница 25: ... 1 OUT 2 OUT 3 OUT 4 OUT 5 R L SPEAKER DC 24V Games Console Power Supply HDMI Speaker Level Outputs Speaker Speaker HDTV Security Door Security Window Projector Screen Network Router LAN Connection Blu ray Player HDMI Inputs Set top Box Satellite Receiver Amplifier RS 232 IR Blasters Optical Output RS 232 Device to be Controlled RS 232 Equipped PC Laptop ...

Страница 26: ...equency 30 50kHz Baud Rate Up to 115200bps Power Supply 24V 3 75A DC US EU standards CE FCC UL certified ESD Protection Human body model 8 kV air gap discharge 6 kV contact discharge Dimensions 219mm W 156mm D 43mm H Jack Excluded 219mm W 176 5mm D 45mm H Jack Included Weight 1272g Chassis Material Metal Color Black Operating Temperature 0 C 40 C 32 F 104 F Storage Temperature 20 C 60 C 4 F 140 F ...

Страница 27: ...720 480 60 720 576p 50 800 600 60 72 75 1024 768 60 70 75 1280 720 50 60 1280 720p 60 1280 768 60 1280 800 60 1280 1024 60 1360 768 60 1600 1200 60 1920 1080i 50 60 1920 1080p 24 25 30 50 60 60 RB 3840 2160 24 25 30 3840 2160 50 60 YUV420 4096 2160 24 25 30 4096 2160 50 60 YUV 420 ...

Страница 28: ...CH only LPCM 7 1CH HDMI if AUDIOFMT BYPASS 2CH only Dolby Digital 2 5 1CH DTS 2 5 1CH HDMI Optical if AUDIOFMT BYPASS Mute Dolby TrueHD DTS HD Master Audio HDMI if AUDIOFMT BYPASS Mute 8 4 Audio Performance 2 45W 4Ω 0 5 THD N 2 12W 8Ω 0 5 THD N Frequency Response 1dB SNR 70dB 20Hz 20kHz a weighted THD N 1W 0 05 1kHz THD N 1W 0 1 20Hz 20kHz ...

Страница 29: ...gital Theater System EDID Extended Display Identification Data GUI Graphical User Interface HDCP High bandwidth Digital Content Protection HDMI High Definition Multimedia Interface HDTV High Definition Television IP Internet Protocol IR Infrared OPT Optical USB Universal Serial Bus ...

Страница 30: ...D R A F T ...

Страница 31: ...D R A F T ...

Страница 32: ...D R A F T Home page http www cypress com tw CYPRESS TECHNOLOGY CO LTD ...

Отзывы: