4. Mounting the Filter System

(A)

Select location under sink or in basement where filter is to be mounted.

NOTE:

Allow 1 

1

/

2

inches (33 mm) clearance below housing or 11-inch below filter head to

enable filter cartridge changes.

CAUTION:

Filter head should be mounted on stud or firm surface. The mounting bracket will 

support the weight of the filter and help prevent strain on the cold water line.

(B)

Filter head should be mounted in vertical position, use mounting bracket as a template to
mark screw locations. Mount filter head in marked location using screws.

CAUTION:

Water supply to the filter should have a separate shut off valve. If it does not, a 

separate shutoff should be installed.

5. Connecting the Supply Adapter and 
Inlet of Filter

(A)

Determine the length of plastic tubing needed to connect the inlet (left) side of the filter with
the supply adapter. Be sure to allow enough tubing to prevent kinking and cut the tubing
squarely. Place a mark 

5

/

8

-inch from the end of the tubing.

(B)

Wet tubing with water and insert into supply adapter 

5

/

8

-inch until mark is flush with fitting.

NOTE:

Disconnecting the Tubing from the Quick-Connect Fittings.

Routine maintenance and cartridge replacement will not require that you disconnect the tubing
from the filter system; however, tubing may be quickly and easily removed from the fitting if
necessary. First, turn off the water supply to the filter. Open faucet, then press in the grey 
collar around the fitting while pulling the tubing with your other hand.

(C)

Slide brass compression nut onto tubing, followed by white plastic ferrule. The long tapered
end of the ferrule should face towards the end of the tubing and the tubing should extend
through the ferrule about 

1

/

4

–inch. Place insert into end of tubing. Insert tubing into inlet of

filter and hand-tighten compression nut. Using a wrench, tighten nut 1 to 1 

1

/

2

turns. Be

careful not to cross thread filter threads.

6. Connecting the Faucet

CAUTION:

Do not over-tighten compression nut. Use caution not to bend or crimp tubes when

securing.

(A)

Determine the length of plastic tubing needed to connect the outlet (right) side of the filter
with the faucet. Measure tubing short enough to prevent kinking and cut the tubing squarely.
Screw nut on faucet stem hand tight, then unscrew two turns.

NOTE:

Compression nut should come preassembled with ferrules inside. If nut should come apart,

see figure 6A for proper assembly.

(B)

Push the tubing firmly into the end of the nut and faucet stem. Hand-tighten compression nut
onto threads until secure. Then tighten 1 

1

/

2

to 2 turns with wrench. 

(C)

Connect outlet of filter using step 5c.

7. Installing the Cartridge

Hold cartridge from the bottom when installing or changing the cartridge. Use caution not to scrape
knuckles on bracket when locking the cartridge into place. Line up the arrow on the cartridge with
unlocked padlock on head. Insert cartridge and turn arrow to locked padlock. See Diagram R4 in
Filter Cartridge Replacement on page 4.

8. Putting the Filter into Operation

(A)

Turn on water supply valve. Check for leaks. If it leaks, see Troubleshooting.

(B)

Rotate base of drinking water faucet counter-clockwise to "on position." Allow water to run for
5 minutes to flush air and carbon fines (very fine black powder).

(C)

Check for leaks before leaving installation. If it leaks, see Troubleshooting.

PLASTIC TUBING

6

B

A

Nut

Insert

Plastic
Ferrule

3

5

A

B

5/8"

16 mm

5/8"

16 mm

5c

Inlet

Outlet

to faucet

4B

Содержание SY-1000S

Страница 1: ...t be left unattended for an extended period of time 146404 Rev D 03 04 Easy Change Under Sink Drinking Water Filter System Installation and Operating Instructions Model SY 1000S Phillips Screwdriver U...

Страница 2: ...ttom of sink with newspaper to prevent metal shavings parts or tools from falling down drain B Place masking tape over the area to be drilled to prevent scratches if drill bit slips C Mark hole with c...

Страница 3: ...uld face towards the end of the tubing and the tubing should extend through the ferrule about 1 4 inch Place insert into end of tubing Insert tubing into inlet of filter and hand tighten compression n...

Страница 4: ...rom the brass fitting Inspect to see if the ferrule and insert are properly installed on the tubing Check if tubing is cut squarely If so reconnect tubing finger tight then tighten nut snug about 1 2...

Страница 5: ...1 NTU 0 5 NTU 99 6 99 7 Lead pH 6 5 0 15 mg L 10 0 010 mg L 99 3 99 3 Lead pH 8 5 0 15 mg L 10 0 010 mg L 98 98 6 Atrazine 0 009 mg L 10 0 003 mg L 97 7 97 7 Lindane 0 002 mg L 10 0 0002 mg L 97 5 97...

Страница 6: ...ER ORAL OR ARISING BY USAGE OF TRADE OR COURSE OF DEALING INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF FITNESS OR MERCHANTABILITY THIS WARRANTY IS THE PURCHASER S SOLE AND EXCLUSIVE REMEDY IN NO EVE...

Страница 7: ...ipalidad o haga examinar el agua por un laboratorio especializado de confianza Se recomienda lavar a fondo el sistema tras largos per odos sin uso por ejemplo durante las vacaciones Deje correr el agu...

Страница 8: ...ara hacer un agujero gu a y luego usando una broca de 1 2 pulgada taladre un agujero completamente a trav s del fregadero Pula los bordes speros con una lima 2 Montaje del grifo A Deslice la peque a j...

Страница 9: ...pulgada Ponga el accesorio de inserci n en la punta del tubo Coloque el tubo en la entrada del filtro y apriete la tuerca de compresi n a mano Apriete la tuerca 1 a 1 y 1 2 vueltas usando la llave Pre...

Страница 10: ...accesorio de inserci n est n instalados adecuadamente en el tubo F jese si el tubo ha sido cortado a escuadra Si fuera as vuelva a conectar el tubo a mano luego apriete bien la tuerca aproximadamente...

Страница 11: ...nte al sistema se redujo a una concentraci n inferior o igual al l mite permitido para el agua que sale del sistema seg n se especifica en las normas NSF 42 de ANSI Cartucho Modelo 750R Substancia Con...

Страница 12: ...O EN EL TRANSCURSO DE LAS NEGOCIACIONES INCLUYENDO SIN LIMITACI N CUALQUIER OTRA GARANT A DE APTITUD Y COMERCIALIZACI N ESTA GARANT A ES EL NICO Y EXCLUSIVO RECURSO DEL COMPRADOR CULLIGAN NO SER RESP...

Отзывы: