![Cylinda 4VI515 Series Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/cylinda/4vi515-series/4vi515-series_service-manual_2704438009.webp)
- 9 -
3.5. Error EE
1. If error displays intermittently, one-time – disruption in temperature
sensor circuit.
Repair: Unplug and plug in.
2. If error displays after 2-4 minutes of switching on cooking zone -
possible damage of sensor or faulty connection.
Repair: Check and verify cooking zones temperature sensors con-
nections (as shown in diagram), if it’s done correctly, replace the
sensor of cooking zone where error displayed.
3.6. Error E5
1. Communication error between control panel and hab module
HG361.01 - 8065761
Solution:
Check the connection. If errror still exist, replace the hab module
8065761
3.7. Damaged fan
Symptoms: Auto switching off the hob after few seconds of work.
Earlier all symbol will light.
Solution: Replace the fan- 1038010