1. Door Types: Wooden door, Glass door, Metal door, Fireproof door.
2. Control Mode: Building intercom system, Access control system.
1. Using powerful power supply, output voltage should be DC12V±10%,cable
>
0.75mm.
2. Don' hurt the galvanization layer during the installation.
3. Ensure the mounting plate well attach to the lock body.
4. The rubber ring must be added between armature plate and door leaf, don't fasten the screw tightly, keep the rubber ring elastic.
5. Don't welded the mounting plate to the door, or will effect the lock.
6. Clean the slushing oil with cloth, don't use alkaline or pungent cleaner.
1. Specification
2. Application Range
3. Note
Read
the manual before usage and keep for future reference.
Electromagnetic Lock
User
Manual
12/24VDC
12/24VDC
12/24VDC
12V/300mA*2
24V/150mA*2
12V/300mA
24V/150mA
170L*42W*21H
12/24VDC
12V/300mA
24V/150mA
180kg(350Lbs)
-180A
-180B
-180AS
-180BS
No
Yes
340L*42W*21H
180kg*2(350Lbs*2)
No
No
No
No
170L*42W*21H
340L*42W*21H
12V/300mA*2
24V/150mA*2
180kg(350Lbs)
180kg*2(350Lbs*2)
No
Yes
Double Door
Double Door
Red
Blue
Black
White
DC12V
POWER
+
-
DC12V
:Connect Red and Blue wire as Positive pole of
Connect
White and Black wire as Negative pole of “-”
“+”,
4. Wiring of Lock (W
)
ithout signal output
Red
Blue
Black
White
DC12V
POWER
+
-
NO
COM
White
White
5. Wiring of Lock (
)
with signal output
DC12V
:Connect Red and Blue wire as Positive pole of
Connect
White and Black wire as Negative pole of “-”
“+”,
Red
Blue
Black
White
DC24V
POWER
+
-
NO
COM
White
White
DC24V
: Red wire is Positive pole of
pole of “-”and connect White and Blue wire.
“+”, black wire is Negative
Red
Blue
Black
White
DC24V
POWER
+
-
DC24V
: Red wire is Positive pole of
pole of “-”and connect White and Blue wire.
“+”, black wire is Negative
EL
EL
EL
EL
EL-180