~8~
3.1.6.
Subprogram resetting all panel settings to the default values. Function inactive if a service key fob was used to enter
programming.
3.1.7.
To enter the programming, you can use the service key fob without knowing the password and serial number of the
panel. Such a key fob should be pre-programmed in the memory of the panel. Entering the subprogram we have a
choice
deletes the key fob and leaves the subprogram
proceeds to add a key fob
after applying a chip to the reader, panel registers it in memory and from now on it is active. You can
add only one key fob. If one is not enough, you can use a cloning device to clone the key fob. In addition, entering the
panel programming using such a key fob blocks the ability to reset the panel settings and change the administrator
password.
3.1.8.
Administrator password. You must type the password twice in order to change it
. If an error
occurs, it means that the same code was not given the second time.
3.1.9.
Displays the software version of the panel
3.2.
Control electronics setting program. It makes changes in the electronics with the serial number programmed in the
program
6 digits. This means that
the panel is paired with a panel with serial number 600001.
3.2.1.
The time of ringing the tenant is set in the range of 5-60 seconds. After entering the subprogram there will appear
Using the '1' and '3' keys, set the desired time and confirm with an asterisk. This function sets the same
time for all physical addresses.
3.2.2.