~1~
INTERCOM WITH DIGITAL DIALING
CC4000 SYSTEM
OPERATING, INSTALLATION AND PROGRAMMING MANUAL
1v1
Страница 1: ...1 INTERCOM WITH DIGITAL DIALING CC4000 SYSTEM OPERATING INSTALLATION AND PROGRAMMING MANUAL 1v1...
Страница 2: ...on 9 3 3 P03 Subscribers 10 3 3 1 Adding a subscriber 10 3 3 2 Deleting a subscriber 10 3 3 3 Simple initialisation of a subscriber table 10 3 3 4 Advanced initialisation of a subscriber table 10 3 3...
Страница 3: ...d resistant steel metal backlit mechanical keyboard and an eight digit alphanumeric display with heating The backlight of the display has a day night brightness adjustment Integrated energy saving UNI...
Страница 4: ...ality cables DETAILED DESCRIPTION of each of the above mentioned devices is provided within dedicated manuals Detailed technical data connector descriptions technical drawings assembly methods accepta...
Страница 5: ...ogramming mode To access the programming mode enter on the keypad the following sequence On the display there will appear a field for entering the serial number of the panel PC 4000 board Enter the se...
Страница 6: ...t is currently stored in the panel will be displayed At this point enter the serial number of the control panel with which you want to pair the panel If the control panel is correctly connected and th...
Страница 7: ...has an additional current output that controls an additional output eg a gate There are several triggering options available output activated from the second uniphone button proximity key tenant code...
Страница 8: ...fob In addition entering the panel programming using such a key fob blocks the ability to reset the panel settings and change the administrator password 3 1 8 Administrator password You must type the...
Страница 9: ...30s and confirm with an asterisk 3 2 5 System activity time of the control panel after the end of the call Enables you to start a call after the call is ended within the programmed time After entering...
Страница 10: ...ber already exists at the physical address an error will be displayed 3 3 2 Deleting a subscriber Enter the subscriber s number not the physical address that you want to delete in the field and confir...
Страница 11: ...he function will appear Set the desired value and confirm with an asterisk 3 3 8 Subscriber table In the first step enter the physical address of the uniphone from which the program starts searching f...
Страница 12: ...ory 3 4 7 Restores all subscriber codes to the default values Compatible with the predefined opening code table 3 5 A program for managing electronic keys stored in the control panel memory 3 5 1 Add...
Страница 13: ...on to PC 4000 panel supply of power we always use a power cable with a minimum cross section of 1mmA 2 Otherwise there is a risk of incorrect system operation UNIPHONES to the CC 4000 board to the L a...
Страница 14: ...each digit pressing If the next digit is selected during this time the program will create the property number from the next digits Attempting to dial a number longer than 4 digits will not change th...
Страница 15: ...ning code and wait NOTE 1 The 0 digit in the code is not a significant number if it is at the beginning of the number and can be omitted 2 If the code has been entered correctly the electric striker w...
Страница 16: ...d and have the markings VPL VPH and GND We connect them directly to the camera module according to the VPL to L VPH to H GND to GND The strike outputs are connected in accordance with the diagram The...
Страница 17: ...EXIT BUTTON STRIKE2 MAIN STRIKE CONTROL ELECTRONICS CC 4000 SUPPLY OF POWER 12V 1A POWER SUPPLY FOR UNIPHONES AND MONITORS CC 4000 ELECTRONICS INTEGRATED IN PANEL...
Страница 18: ...in the SLAVE connector matches the order on the panel board 1 1 The strike outputs are connected in accordance with the diagram The main strike can be a jumper strike reversing strike with a maximum c...
Страница 19: ...EXIT BUTTON STRIKE2 MAIN STRIKE CONTROL ELECTRONICS CC 4000 SUPPLY OF POWER 12V 1A POWER SUPPLY CC 4000 ELECTRONICS INTEGRATED IN PANEL FOR UNIPHONES...
Страница 20: ...d As a rule it should be the electronics to which the connecting cables have the shortest route It should be noted that the MASTER connector on the CC 4000 board does not have a 12V terminal All MASTE...
Страница 21: ...Y OF POWER 12V 1A POWER SUPPLY SUPPLY OF POWER 12V 1A POWER SUPPLY CONTROL ELECTRONICS CC 4000 FOR SUBSEQUENT STAIRCASES FOR UNIPHONES AND MONITORS FOR UNIPHONES AND MONITORS MAIN INPUT 1 EXIT BUTTON...
Страница 22: ...vice key fob In order to facilitate the installation procedure you can assign an RFID proximity key to the PC 4000 panel The key is assigned to the program in subprogram 7 In order to use the key adde...
Страница 23: ...y removing the handset pressing the opening button etc ATTENTION The time required to scan the whole line of 255 uniphones is about 5 minutes which is why it is recommended to narrow the search ranges...
Страница 24: ...umber eg 1 confirm with an asterisk and only enter the number of the tenant you are interested in Without using the serial number and system number The BASIC type MASTER panel sends a request to all c...
Страница 25: ...tered E14 Short circuit of uniphone line Voltage of uniphone line below 3V E15 Codes do not match When changing the installer passcode different passcodes have been given in two steps E17 Number out o...