background image

8

Version 1.0

The RDM protocol allows data packets to be inserted into a DMX512 data stream without affecting 

existing non-RDM equipment. It allows a console or dedicated RDM controller to send commands to and 

receive messages from specific fixtures.

With RDM function, you can set the DMX address of your fixtures remotely. This is especially useful 

when the device is installed in a remote area.

Each FR-150W has a factory set RDM UID (unique identification number).

Zoom

Step 1: Loosen the zoom button on the top of the device, toward the back.

Step 2: Adjust the zoom by sliding the zoom button forward or backward.

Step 3: Tighten the zoom button.

DMX Protocol

1 Channels Mode

Function

Function Control

CH1

Dimmer

000-255: 0-100% dimmer

2 Channels Mode

Function

Function Control

CH1

Dimmer

000-255: 0-100% dimmer

CH2

Strobe

000-255: strobe with speed increasing

3 Channels Mode

Function

Function Control

CH1

Dimmer

000-255: 0-100% dimmer

CH2

Strobe

000-255: strobe with speed increasing

CH3

Dimmer mode

000-050: Dimmer speed 0 (no delay)
051-100: Dimmer speed 1
101-150: Dimmer speed 2
151-200: Dimmer speed 3
201-255: Dimmer speed 4 (slowest speed)

4 Channels Mode

Function

Function Control

CH1

Dimmer

000-255: 0-100% dimmer

CH2

Strobe

000-255: strobe with speed increasing

CH3

Dimmer mode

000-050: Dimmer speed 0 (no delay)
051-100: Dimmer speed 1
101-150: Dimmer speed 2
151-200: Dimmer speed 3
201-255: Dimmer speed 4 (slowest speed)

Содержание FR-150W

Страница 1: ...USER MANUAL FR 150W 150 watts COB Warm White LED Powered Fresnel...

Страница 2: ...curing with a safety cable 5 DMX 512 connection connection between fixtures 5 Power connection 6 Operation 6 Control Menu Map 6 Addressing 7 Universal DMX Control 7 RDM control 7 Zoom 8 DMX Protocol 8...

Страница 3: ...s of the housing can become hot during operation After use wait for a cool down period of at least 10 minutes before handling or transporting the device Every person involved with the installation ope...

Страница 4: ...sion 1 0 Overview Safety cable anchor point Zoom knob Yoke Accessories clip Yoke locking knob Lens Dmx out Dmx in Power out Power in On off switch Enter button Down button Up button Menu button LED di...

Страница 5: ...access under the work area 3 Fold the legs of the mounting bracket together and bolt a rigging clamp securely to the mounting bracket The bolt used must be M10 grade 8 8 steel minimum It must pass thr...

Страница 6: ...into a 3 pin XLR plug and plug it in the DMX output of the last fixture Power connection Power Requirements The FR 150W luminaire operates on 100 to 240 volts AC 10 auto ranging The luminaire contains...

Страница 7: ...ill start to listen to the same control signal from the same channel number In other words changing the settings of one channel will affect all the fixtures simultaneously If you set a different addre...

Страница 8: ...ackward Step 3 Tighten the zoom button DMX Protocol 1 Channels Mode Function Function Control CH1 Dimmer 000 255 0 100 dimmer 2 Channels Mode Function Function Control CH1 Dimmer 000 255 0 100 dimmer...

Страница 9: ...D30 242 ID53 080 089 ID8 220 ID31 243 ID54 090 099 ID9 221 ID32 244 ID55 100 109 ID10 222 ID33 245 ID56 110 119 ID11 223 ID34 246 ID57 120 129 ID12 224 ID35 247 ID58 130 139 ID13 225 ID36 248 ID59 140...

Страница 10: ...cotton swab moistened with glass cleaner or distilled water 4 Check that the fixture is dry before reapplying power Fuse Replacement This fuse is located in a fuseholder next to the MAINS OUT socket o...

Страница 11: ...2m 10 5 Dimmer curves Strobe Video flicker free with selectable PWM Silent operation Barn doors included Control protocols DMX RDM Control channels 1 2 3 4 CHs Input voltage AC100 240V 50 60Hz DMX co...

Отзывы: