,IQHFHVVDU\WRDFKLHYHWKH´PLQLPXPFOHDUDQFHDERYHWKHKLJKHVW
DQWLFLSDWHGVQRZOHYHOLQVWDOODVQRUNHODVVKRZQLQERWWRPSRUWLRQ
RI
Figure 19
.
Note:
:LWKWKHLQVWDOODWLRQRIDVQRUNHOLWLVQHFHVVDU\WRXVH
WZRHOERZVWKDWVKDOOEHFRQVLGHUHGDORQJZLWKWKH
DGGLWLRQDOYHQWSLSHZKHQFDOFXODWLQJPD[LPXPHTXLYDOHQW
IHHWRIYHQWLQJ
VERTICAL VENT TERMINATION INSTALLATION
$SURSHUÀDVKLQJRU³%227´VKRXOGEHXVHGWRVHDOWKHSLSHZKHUHLW
H[LWVWKHURRI7KHWRWDOYHQWV\VWHPVKRXOGQRWH[FHHGWKHHTXLYDOHQW
IHHWRISLSHDVOLVWHGLQ7DEOH
3URYLGHVXSSRUWIRUDOOSLSHSURWUXGLQJWKURXJKWKHURRI$OOSLSLQJVKRXOG
EHSURSHUO\VHFXUHG7KHYHQWV\VWHPSLSLQJVKRXOGEHVXSSRUWHG
HYHU\ IHHW P RI YHUWLFDO UXQ DQG HYHU\ IHHW FP RI
KRUL]RQWDOUXQ)ROORZYHQWSLSHPDQXIDFWXUHU¶VLQVWUXFWLRQVIRUSURSHU
MRLQLQJSURFHGXUHV
Figure 19. Through-the-Roof Vent Installation
Important:
7KHYHQWV\VWHPPXVWWHUPLQDWHVRWKDWSURSHU
FOHDUDQFHVDUHPDLQWDLQHGDVFLWHGLQORFDOFRGHV
RUWKHFXUUHQWHGLWLRQRIWKH
National Fuel Gas Code
(ANSI Z223.1)
RUWKH
Natural Gas and Propane Installation
Code (CAN/CSA-B149.1)
DQGDVOLVWHGEHORZ
Note:
9HQW7HUPLQDWLRQPXVWH[WHQGDPLQLPXPRILQFKHV
FPDERYHURRIRULQFKHVFPDERYHWKHDQWLFLSDWHG
VQRZOHYHOWRSUHYHQWEORFNDJHRIWKHYHQWWHUPLQDWLRQDV
VKRZQLQ
Figure 18
DQG
Figure 19
SDJH
.
VENT PIPE PREPARATION
INITIAL PREPARATION
1.
0DNHVXUHWKHVROYHQWFHPHQW\RXDUHSODQQLQJWRXVHLVGHVLJQHG
IRUWKHVSHFL¿FDSSOLFDWLRQ\RXDUHDWWHPSWLQJ
2.
.QRZWKHSK\VLFDODQGFKHPLFDOFKDUDFWHULVWLFVDQGOLPLWDWLRQVRI
WKH39&DQG&39&SLSLQJPDWHULDOVWKDW\RXDUHDERXWWRXVH
3.
.QRZWKHUHSXWDWLRQRI\RXUPDQXIDFWXUHUDQGWKHLUSURGXFWV
4.
.QRZ\RXURZQTXDOL¿FDWLRQVRUWKRVHRI\RXUFRQWUDFWRU7KH
VROYHQWZHOGLQJWHFKQLTXHRIMRLQLQJ39&DQG&39&SLSHLVD
VSHFLDOL]HGVNLOOMXVWDVDQ\RWKHUSLSH¿WWLQJWHFKQLTXH
5.
&ORVHO\VXSHUYLVHWKHLQVWDOODWLRQDQGLQVSHFWWKH¿QLVKHG MRE
EHIRUHVWDUWXS
A.
&RQWDFWWKHPDQXIDFWXUHUVXSSOLHURUFRPSHWHQWFRQVXOWLQJ
DJHQF\LI\RXKDYHDQ\TXHVWLRQVDERXWWKHDSSOLFDWLRQRU
LQVWDOODWLRQRI39&DQG&39&SLSH
B.
7DNHWKHWLPHDQGHႇRUWWRGRDSURIHVVLRQDOMRE6KRUWFXWV
ZLOO RQO\ FDXVH \RX SUREOHPV DQG GHOD\V LQ VWDUWXS %\
IDUWKHPDMRULW\RIIDLOXUHVLQ39&DQG&39&V\VWHPVDUH
WKHUHVXOWRIVKRUWFXWVDQGRULPSURSHUMRLQLQJWHFKQLTXHV
6. SELECTION OF MATERIALS
•
&XWWLQJ'HYLFH6DZRU3LSH&XWWHU
•
'HEXUULQJ7RRO.QLIH)LOHRU%HYHOLQJ0DFKLQH´DQG
DERYH
•
%UXVK3XUH%ULVWOH
•
5DJ&RWWRQ1RW6\QWKHWLF
•
3ULPHUDQG&OHDQHU
•
6ROYHQW&HPHQW39&IRU39&&RPSRQHQWVDQG&39&
IRU&39&&RPSRQHQWV
•
&RQWDLQHUV0HWDORU*ODVVWRKROG3ULPHUDQG&HPHQW
6HOHFWWKHW\SHRI39&RU&39&PDWHULDOVWREHXVHG
RQWKHEDVLVRIWKHLUDSSOLFDWLRQZLWKUHVSHFWWRFKHPLFDO
UHVLVWDQFHSUHVVXUHUDWLQJWHPSHUDWXUHFKDUDFWHULVWLFV
HWF
•
,QVHUWLRQ7RRO +HOSIXO IRU ODUJHU GLDPHWHU SLSH DQG ¿W
-
WLQJVLQFKHVFPDQGDERYH
Fire or Explosion Hazard
Read instruction manual before
installing, using or servicing
water heater.
Avoid all ignition sources if you smell gas.
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
Use only the gas shown on the water heater rating label.
Keep ignition sources away from faucets after extended
periods of non-use.
Maintain required clearances to combustibles.
Do not expose water heater controls to excessive gas
pressure.
Primer
,W LV UHFRPPHQGHG WKDW 7HWUDK\GURIXUDQ 7+) EH XVHG WR
SUHSDUHWKHVXUIDFHVRISLSHDQG¿WWLQJVIRUVROYHQWZHOGLQJ
'RQRWXVHZDWHUUDJVJDVROLQHRUDQ\RWKHUVXEVWLWXWHVIRU
FOHDQLQJ39&RU&39&VXUIDFHV$FKHPLFDOFOHDQHUVXFKDV
0(.PD\EHXVHG
Cement
7KHFHPHQWVKRXOGEHDERGLHGFHPHQWRIDSSUR[LPDWHO\
WR FHQWLSRLVH YLVFRVLW\ FRQWDLQLQJ E\ ZHLJKW
YLUJLQ39&PDWHULDOVROYDWHGZLWKWHWUDK\GU)6PDOO
TXDQWLWLHVRIGLPHWK\OIRUPDPLGH'0)PD\EHLQFOXGHGWRDFW