CG110 CG180 Installation - English

IMPORTANT SAFETY INSTRUCTIONS

1. Use the product only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

2. Before servicing or cleaning the product, switch off the power at the main service panel and lock it to prevent the

power from accidentally being turned on. If the panel cannot be locked securely, fasten a prominent warning device,

such as tag, to it. If the fan is not hard-wired but rather plugged into a 120 Volt outlet, unplug the cord from the

receptacle.

3. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes

and standards, including fire-rated construction codes and standards.

4. Sufficient air is needed for proper combustion and exhaust of gases through the flue (chimney) of fuel burning

equipment to prevent back drafting. Follow the heating equipment manufacturer’s guidelines and safety standards such

as those published by the National Fire Protection Association (NFPA), and the American Society for Heating,

Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

6. The exhaust fans must always be vented to outdoors.

7. The fan may have sharp edges. Use caution to avoid being cut when installing and cleaning.

8. The fan must be grounded.

•  READ CAREFULLY AND SAVE THESE INSTRUCTIONS TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND 

PERSONAL INJURY. 

WARNING

1. for general ventilation use only. Not for use in fire rated installations. Do not use the fan to exhaust hazardous or explosive 

materials and vapors. 

2. for interior use only. Mount with the lowest moving parts at least 8 feet (2.5 meters) above the floor or grade level. 

3. To avoid the motor damage and noisy and/or unbalanced impeller, keep drywall spray, construction dust, etc. off the power unit. 

4. Prior to installation operations make sure there is no visible damage to the impeller and housing. Also make sure there are no 

foreign objects in the fan. 

5. Please read specification label on product for further information and requirements. 

6. Connect the fan through a breaker box. 

7. Both the inlet and outlet must have no obstructions for the fan to work properly and be covered by the warranty. 

8. When storing the fan keep it in a dry, weather-protected environment in the original packaging. If the fan has been stored or set 

in a cold environment, wait 2 hours before connecting it to the power source. 

 CAUTION

Содержание CG110

Страница 1: ...on and Operation Instructions Please read all instructions before installing and operating All wiring and installation must be in accordance with CEC NEC and local electrical codes READ AND SAVE THESE...

Страница 2: ...2 CG110 CG180 Installation English...

Страница 3: ...to wall or ceiling do not damage electrical wiring and other hidden utilities 6 The exhaust fans must always be vented to outdoors 7 The fan may have sharp edges Use caution to avoid being cut when in...

Страница 4: ...product 5 Introduction 5 Use 6 Delivery set 6 Designation key 7 Main technical parameters 7 Design and operating logic 8 Mounting and set up 9 Connection to power mains 9 Unit control 10 Maintenance...

Страница 5: ...ation kit and drill a round core hole Its diameter must match the air duct diameter Fig 2 2 Insert the air duct in the hole and fix it with a mounting foam Fig 3 3 Install the fan Fig 4 9 4 Install th...

Страница 6: ...6 CG110 CG180 Installation English TYPICAL INSTALLATION AIR DUCT INSTALLATION min 3...

Страница 7: ...7 CG110 CG180 Installation English INSTALLATION OF LD KIT TO THE WALL INSTALLATION OF OUTER HOOD...

Страница 8: ...E JUNCTION BOX GROUND FAN FAN INTERNAL SWITCH N L N L 120V 60Hz X QF STANDARD WALL SOCKET CONNECTION OF CG KIT IN STANDARD WALL SWITCH S JUNCTION BOX 120VAC 60Hz HOUSE POWER STANDARD WALL SWITCH QF AU...

Страница 9: ...roper maintenance use of corrosive and abrasive cleaning products d products or parts which have been subject to freight damage misuse negligence accident or any other circumstances beyond the control...

Страница 10: ...re toutes les instructions avant d installer et d utiliser la hotte Les travaux d installation et les branchements lectriques doivent satisfaire aux exigences du Code canadien de l lectricit CCE et du...

Страница 11: ...2 Installation d une CG110 CG180 Fran ais...

Страница 12: ...ur 7 Le rebord du ventilateur pourrait tre coupant Faites preuve de prudence afin de pr venir les coupures lors de l installation et du nettoyage 8 Le ventilateur doit tre mis la terre LISEZ LES PR SE...

Страница 13: ...dre le num ro de mod le 5 Installation 5 Conditions de fonctionnement 5 Entretien 5 Installation typique 6 Installation de la conduite d air 6 Installation de l ensemble CG au mur 7 Installation de la...

Страница 14: ...yst me de ventilation sera install et percez un trou rond de diam tre correspondant aux dimensions de la conduite d air image 2 2 Ins rez la conduite d air dans le trou et fixez la l aide de mousse de...

Страница 15: ...6 Installation d une CG110 CG180 Fran ais INSTALLATION TYPIQUE INSTALLATION DE LA CONDUITE D AIR min 3...

Страница 16: ...7 Installation d une CG110 CG180 Fran ais INSTALLATION DE L ENSEMBLE CG AU MUR INSTALLATION DE LA HOTTE EXT RIEURE...

Страница 17: ...OMMUTATEUR AUTOMATIQUE QF VIS DE BORNE DE TERRE VERTE 120 VAC 60Hz ALIMENTATION DE LA MAISON PRISE MURALE STANDARD TERRE VENTILATEUR COMMUTATEUR INTERNE DU VENTILATEUR BO TE DE JONCTION DE LA MAISON C...

Страница 18: ...ag s pendant le transport ou la suite d un mauvais usage d une n gligence ou d un accident ou dans toute autre circonstance ind pendante de la volont de la soci t e en outre cette garantie n est pas a...

Отзывы: