background image

The information in this document has been carefully checked and is believed to be entirely reliable. However, no
responsibility is assumed for inaccuracies. Furthermore, Cyclone Microsystems, Inc. reserves the right to make
changes to any products herein to improve reliability, function, or design. Cyclone Microsystems, Inc. neither
assumes any liability arising out of the application or use of any product or circuit described herein, nor does it
convey any license under its right or the rights of others.

Revision 1.0, March 2005

Cyclone P/N 800-2400-31

Copyright 2005 by Cyclone Microsystems, Inc.

2400-31

FRONT END PROCESSOR 

MAINTENANCE & 

SUPPORT GUIDE

Содержание 2400-31

Страница 1: ...nges to any products herein to improve reliability function or design Cyclone Microsystems Inc neither assumes any liability arising out of the application or use of any product or circuit described h...

Страница 2: ...Connector 2 7 2 3 4 E1 Connectors 2 8 CHAPTER 3 3 1 FEP INITIALIZATION AND BUILT IN SELF TEST 3 1 CHAPTER 4 4 1 PERIODIC MAINTENANCE 4 1 CHAPTER 5 5 1 SERVICEABLE COMPONENTS 5 1 5 2 BOARD REMOVAL AND...

Страница 3: ...31 FEP Maintenance Support Guide Revision 1 0 March 2005 7 4 EFFECTIVE PERIOD OF WARRANTY 7 1 7 5 REPAIRED OR REPLACEMENT PRODUCT OUT OF WARRANTY 7 1 7 6 SERVICE POLICY 7 2 APPENDIX A A 1 ADDITIONAL...

Страница 4: ...EP Part Numbering 1 1 Figure 2 1 600 2400 31 D0 FEP Front Panel 2 1 Figure 2 2 600 2400 31 A0 FEP Front Panel 2 2 Figure 2 3 600 2400 31 FEP Front Panel LEDs 2 3 Figure 2 4 DC Power Connector 2 5 Figu...

Страница 5: ...00 31 FEP Front Panel LED Description 2 3 Table 2 4 Ring Lugs for 10 Studs 2 6 Table 2 5 Console Port Connector 2 7 Table 2 6 Ethernet Port Connector 2 7 Table 2 7 E1 ATM Port 0 Connector Pin Assignme...

Страница 6: ...lso monitors power supply fan status and temperature in an effort to detect and provide early alert to component failures The part numbering system for the 600 2400 series of FEPs is as shown in Figur...

Страница 7: ...rsuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment gen...

Страница 8: ...ower Connector B 4 FEP Power supply ON OFF Switch B 5 FEP Reset Switch 6 FEP Ground Lugs 7 CPCI 821 8 CPCI 817 1 9 CPCI 817 2 10 Power Supply A 11 Power Supply B 12 Fan Filter Assembly FRONT END PROCE...

Страница 9: ...21 FN1 Turns on and remains on for FAN1 good condition and turns off for FAN1 failure 5 0 CPCI 821 LPX Turns on and remains on for local PCI bus running PCI X and turns off for local PCI bus not runni...

Страница 10: ...ink integrity for Ethernet port 1 and will remain on continuously if port 1 is connected to a functional network or Ethernet port 15 CPCI 817 ST0 Indicates status 0 for CPCI 817 and will light for a s...

Страница 11: ...CTORS 2 3 1 Power Connector There are two power supply connectors on the right hand side of the FEP 2 3 1 1 DC Power Connectors 600 2400 31 D0 The DC power connector is military style circular bayonet...

Страница 12: ...ceptacle Figure 2 5 AC Power Connector 2 3 1 3 Ground Studs There are two 10 32 threaded studs with hex nuts flat washers and star washers included attached to the chassis of the 600 2400 31 A0 and 60...

Страница 13: ...821 console connector A cable connecting the console port to a standard DB25 connector is available from Cyclone Microsystems P N 530 2006 A terminal or PC running a terminal emulation program should...

Страница 14: ...he connector is not connected to chassis ground The shield of the connector is RING and the center conductor is TIP Figure 2 6 75ohm BNC Connector Table 2 7 E1 ATM Port 0 Connector Pin Assignments Tab...

Страница 15: ...will indicate the last successfully completed stage of the board initialization sequence The following table describes the startup LEDs Table 3 1 CPCI 817 Initialization and Self Test LEDs User LED Pa...

Страница 16: ...Passed ACT External Bus Controller Initialized ST0 Local Bus Priorities Set ST1 Interrupt Controller Initialized IOP UART Initialized ACT ST0 Reset Status Check Done ACT ST1 I2C Bus Initialized ACT IO...

Страница 17: ...er supplies The fan and air filter assembly is located on the left hand side of the FEP unit Replacement filters can be purchased from Cyclone Microsystems Cyclone part number 370 1303 Table 4 1 Air F...

Страница 18: ...y handled with a ground strap and transported in an ESD shielded bag Turn power off Disconnect cables from the board Loosen the two retaining screws on the boards front panel The retaining screws are...

Страница 19: ...Filter Assembly Installation Align the flanges in the Fan Filter assembly with its guides after replacing the fan and slide the Fan Filter access panel into the unit 5 4 POWER SUPPLY REMOVAL AND INST...

Страница 20: ...ailures per billion hours Mean Time Between Failures MTBF is the inverse of the failure rate and is the average time between failures 6 2 ASSUMPTIONS Ambient input air temperature does not exceed 30 d...

Страница 21: ...17 CM817 064 T 2 3028 330 250 DC Power Supply 2400 Chassis 370 1301 1 2172 460 405 Fan Filter Assembly 2400 Chassis 370 1300 1 100 6914 144 634 600 2400 31 A0 1 CPCI 821 CM821 064 00 T3 1 1614 619 409...

Страница 22: ...r repair without charge any defective component of such products 7 3 SOFTWARE AND FIRMWARE Cyclone warrants that Software and Firmware supplied shall conform to the then current published documentatio...

Страница 23: ...r incidental or consequential damages of any kind arising out of the sale installation or use of its products 7 6 SERVICE POLICY Out of repair warranty will be accomplished expeditiously at a charge p...

Страница 24: ...ALS A 1 ADDITIONAL INFORMATION Additional information for each of the boards used in the FEP can be found in their respective User s Manual These manuals are available from Cyclone Microsystems Part N...

Отзывы: