Cybex Pro+ Treadmill Service Manual
Preventive
Maintenance
Page 2-2
Cleaning Your Treadmill
When cleaning your treadmill spray a mild cleaning agent, such as a water and dishsoap solution,
on a clean cloth fi rst and then wipe the treadmill with the damp cloth.
NOTE: Do not spray cleaning solution directly on the treadmill. Direct spraying could cause damage to
the electronics and may void the warranty.
! WARNING: To prevent electrical shock, be sure that power is shut off and the treadmill is
unplugged from the electrical outlet before performing any cleaning or maintenance
procedures.
After Each Use –
Wipe up any liquid spills immediately. After each workout, use a cloth to wipe up any
remaining perspiration from the handrails and painted surfaces.
Be careful not to spill or get excessive moisture between the edge of the display panel and the console,
as this might create an electrical hazard or cause failure of the electronics.
As Needed –
Vacuum any dust or dirt that might accumulate under or around the treadmill. Motors are
especially susceptible to dust and dirt, and restricted airfl ow can prevent adequate cooling that could
shorten motor life. Cleaning this area should be done as often as indicated in the Service Schedule, more
often in dusty environments.
! WARNING: Keep wet items away from inside parts of the treadmill. Electrical shock could occur
even if the treadmill is unplugged. Do not touch components on the lower board.
A charge can remain after unplugging the power cord and turning off the treadmill.
To clean the motor components, you must loosen the six Phillips screws that hold the motor cover in
place. Lift the cover straight up; the screws and side covers will stay in place. Use a vacuum attachment
or hand vacuum to clean the exposed elevation assembly, drive motor, lower electronics and the
surrounding areas.
Also use a dry cloth for the areas that you can't reach with the vacuum cleaner. If the machine has not
been used for some time or is excessively dirty, use a
dry
cloth to wipe all exposed areas. Replace the
cover and tighten the screws when fi nished.
Lift the rear of the treadmill and roll it back from its present position so as to vacuum the fl oor area
underneath the unit. Wipe clean the underside of the treadmill to prevent dirt and dust build-up. When
fi nished, return the treadmill to its normal position.
Contact Heart Rate Grips –
Contaminants, such as hand lotions, oils or body powder, may come off
on the contact heart rate grips. These can reduce sensitivity and interfere with the heart rate signal. It is
recommended that the user have clean hands when using the contact heart rate. Clean the grips using
a cloth dampened with a cleaning solution containing alcohol. The grips are the only part of the treadmill
you should use a cleaning solution containing alcohol.
Содержание Pro+
Страница 2: ......
Страница 4: ......
Страница 6: ...Page ii This page intentionally left blank ...
Страница 8: ...Cybex Pro Treadmill Service Manual Page iv This page intentionally left blank ...
Страница 14: ...Safety Page 1 6 Cybex Pro Treadmill Service Manual ...
Страница 24: ...Cybex Pro Treadmill Service Manual Preventive Maintenance Page 2 8 This page intentionally left blank ...
Страница 68: ...Cybex Pro Treadmill Service Manual Service Page 4 40 This page intentionally left blank ...