Shenzhen Zhiyong Electronics Co., Ltd.
7
4. Electric Specification
Modal
DP6070
DP6150(A/B)
DP6280
DP6700(A)
Bandwidth(-3dB
)
70MHz
DP6150
70MHz
100MHz
DP6700
70MHz
DP6150A
100MHz
DP6700A
100MHz
DP6150B
200MHz
Rise time
≤5ns
DP6150
≤5ns
≤3.5ns
DP6700
≤5ns
DP6150A ≤3.5ns
DP6700A ≤3.5ns
DP5150B ≤1.75ns
Accuracy
±2%
±2%
±2%
±2%
Range selection(Attenuation
rate)
10X/100X
50X/500X
100X/1000X
100X/1000X
Maximum differential
voltage(DC + Peak AC)
10X
±70V
50X
±150V
100X
±280V
100X
±700V
100X
±700V
500X
±1500V
1000X
±2800V
1000X
±7000V
Common mode
voltage(DC + Peak AC)
±700V
±1500V
±2800V
±7000V
Maximum differential mode
VS frequency curve
Reference
Figure 1
Figure 2
Figure 3
Figure 4
Maximum input
voltage-to-earth (Vrms)
450V CATII
600V CATI
600V CATIII
1000V CATII
600V CATIII
1000V CATII
1000V CATIII
2300V CATI
Input
impedance
Single-ended
to ground
2.5M
Ω
5M
Ω
5M
Ω
20M
Ω
Between
inputs
5M
Ω
10M
Ω
10M
Ω
40M
Ω
Input
capacitance
Single-ended
to ground
<4pF
<4pF
<4pF
<5pF
Between
inputs
<2pF
<2pF
<2pF
<2.5pF
CMRR
DC
>80dB
>80dB
>80dB
>80dB
100kHz
>60dB
>60dB
>60dB
>60dB
1MHz
>50dB
>50dB
>50dB
>50dB
Noise(Vrms)
10X
<20mV
50X
<50mV 100X
<100mV 100X
<200mV
100X
<120mV
500X
<300mV 1000X
<600mV 1000X
<1.2V
Differential overvoltage
detection level
10X
≥70V
50X
≥150V
100X
≥280V
100X
≥700V
100X ≥700V
500X
≥1500V
1000X ≥2800V
1000X
≥7000V
Propagation
time
Probe
About 9ns
BNC
Line(1m)
About 5ns
Bandwidth limit filters (5MHZ)
≥-3dB@5MHz
Overload indicator (red light
)
Yes
Overload alarm
Yes(Can shut up manually)
Automatic save
Yes
Offset setting function
Yes
(
Set in test mode
)
Terminate load
≥100k
Ω
Power supply
USB 5V/1A adapter
Safety standard
EN61010-1: 2010
EMC standard
EN61326-1:2013 EN61000-3-2:2006+A1:2009+A2:2009 EN61000-3-3:2013
CYBERTEK