Navigation Buttons 

Connect/Disconnect  

To establish the drive redirection please press the 

Connect

 button once. If all the settings 

are correct, the status bar displays that the connection has been established, the Connect 
button is disabled and the Disconnect button is enabled. 

On an error, the status line shows the error message. The drive redirection software tries to 
lock the local drive before it is redirected. That means that it tries to prevent the local 
operating system from accessing the drive as long as it is redirected. This may also fail, 
especially if a file on the drive is currently open. In the case of a locking failure, you will be 
prompted if you want to establish the connection anyhow. This should not be a serious 
problem when the note above is respected. If the write support is enabled, a drive which is 
not locked might be damaged by the Drive Redirection. 

With the 

Disconnect

 button, a connection via Drive Redirection connection is stopped. 

Exit/Hide

If the 

Exit

 button is pressed, the Drive Redirection software is closed. If a Drive Redirection 

connection is active, the connection will be closed before the application terminates. 

Using the Hide to Tray button the application is hidden, but not terminated completely. That 
means that an active connection will be kept active until it is closed explicitly. You can 
access the software by its tray icon. The tray icon also shows whether a connection is 
established or not. A double click on the icon shows the application window, or with a right 
click you may access a small menu 

GFC IPM  

 

CyberResearch

® 

KVM Accessories 

 

46

  

©Copyright 2009 

CyberResearch, Inc.

 

 

 

 

Содержание GFC IPM

Страница 1: ...t of this manual may be reproduced without permission GFC IPM IP Module Provides Control over IP for GFC Series FoldAways CyberResearch Inc www cyberresearch com 25 Business Park Dr Branford CT 06405...

Страница 2: ......

Страница 3: ...dentification purposes only and may be trademarks and or registered trademarks of their respective companies NOTICE CyberResearch Inc does not authorize any CyberResearch product for use in life suppo...

Страница 4: ...GFC IPM CyberResearch KVM Accessories Revision History Revision Description Date of Issue 2 5 Previous Release March 21 2007 3 0C Revision November 14 2009 2 Copyright 2009 CyberResearch Inc...

Страница 5: ...st system mouse settings 18 4 2 5 Single and Double Mouse Mode 19 4 2 6 Recommended Mouse Settings 19 4 2 7 Video Modes 19 5 Usage 20 5 1 Prerequisites 20 5 2 Login into the GFC IPM switch and logout...

Страница 6: ...rtificate 61 6 6 5 Serial Port 64 6 6 6 Date And Time 66 6 6 7 Event Log 67 6 7 Maintenance 69 6 7 1 Device Information 69 6 7 2 Even log 70 6 7 3 Update Firmware 71 6 7 4 Unit Reset 72 7 Troubleshoot...

Страница 7: ...rm the following steps 1 Optional Connect the type A connector of USB A B cable to the host computer while using remote mass storage control 2 Connect Ethernet to LAN port and or modem to serial port...

Страница 8: ...DHCP server in the subnet to which it is physically connected If a DHCP server is found it may provide a valid IP address gateway address and net mask Before you connect the device to your local subn...

Страница 9: ...and password for Authentication default super pass c Click Setup Device If super login was authenticated it ll show Successfully configured device Otherwise it ll show Permission Denied CyberResearch...

Страница 10: ...Password pass Changing default username and password to user specific values is strongly recommended and can be done on the User Management page see the Section called Users and Groups in Chapter 6 C...

Страница 11: ...tings on the host system In general there is no need to change mouse settings on the host Video Settings in Options Menu This opens a new window with elements to control the GFC IPM switch Video Setti...

Страница 12: ...utomatically detect the current video mode of the console however manual fine tuning is recommended to receive the best video quality GFC IPM switch will accept video streams up to 110 MHz dot clock T...

Страница 13: ...supported Network Connection 10 100 Ethernet Telephone line modem needed Management Interface Web Utility Telnet Serial Port Event log NFS SMTP SNMP trap Hardware Host side USB USB 2 0 Type B Keyboard...

Страница 14: ...intenance of the server Using the Console Redirection Service you are able to do the following I Reboot the system II Watch the boot process III Boot the system from a separate partition to load the d...

Страница 15: ...ower supply is on but there is no video output CPU fan failure By server specific management software RAM failure Boot Sequence on boot console Table 2 1 Host system failures and how they are detected...

Страница 16: ...e 4 1 Initial Network Configurations GFC IPM switch Setup Tool If this initial configuration does not meet your local requirements use the setup tool to change the configurations to your needs The set...

Страница 17: ...d for Authentication default super pass c Click Setup Device If super login was authenticated it ll show Successfully configured device Otherwise it ll show Permission Denied CyberResearch KVM Accesso...

Страница 18: ...has a serial line interface host side This connector is compliant with the RS 232 serial line standard The serial line has to be configured with the parameters given in Table 4 2 When configuring with...

Страница 19: ...ion of the remote mouse depends on several settings which will be discussed in the following subsections 4 2 1 GFC IPM switch keyboard settings The GFC IPM switch settings for the host s keyboard type...

Страница 20: ...there are no window at the top left corner of the remote desktop that are able to change the mouse cursor shape from the normal state The Sync mouse button on top of the Remote Console can behave dif...

Страница 21: ...eave this mode it is necessary to define a mouse hotkey in the Remote Console Settings Panel Press this key to free the captured local mouse pointer 4 2 6 Recommended Mouse Settings For the different...

Страница 22: ...browser has to come with a Java Runtime Environment version 1 4 2 or above If the browser has no Java support such as on a small handheld device you are still able to maintain your GFC IPM switch usin...

Страница 23: ...URL field of your browser when establishing an unsecured connection http IP address of GFC IPM switch When using a secure connection type in https IP address of GFC IPM switch This will lead you to th...

Страница 24: ...not possible Navigation Having logged into the GFC IPM switch successfully the main page of the GFC IPM switch appears see Figure 5 3 This page consists of three parts each of them contains specific...

Страница 25: ...tries to establish its own TCP connection to the GFC IPM switch The protocol that is run over this connection is neither HTTP or HTTPS but RFB Remote Frame Buffer Protocol As default RFB tries to est...

Страница 26: ...sh keyboard layout for instance special keys on the German keyboard will not work as expected Instead the keys will result in their US English counterpart You can circumvent such problems by adjusting...

Страница 27: ...he local with the remote mouse cursor This is especially necessary when using accelerated mouse settings on the host system In general there is no need to change mouse settings on the host Single Doub...

Страница 28: ...igure 5 7 Remote Console Exclusive Mode Scaling Allow you to scale down the Remote Console You can still use both mouse and keyboard however the scaling algorithm will not preserve all display details...

Страница 29: ...on the Java Virtual Machine a version of 1 4 2 or above offers the full list Figure 5 9 Remote Console Options Menu Cursor Video Settings Opens a panel for changing the GFC IPM switch video settings G...

Страница 30: ...be suitable for most situations Video Settings through the remote console Figure 5 10 Video Settings Panel Brightness Controls the brightness of the picture Contrast Controls the contrast of the pict...

Страница 31: ...o again from the controlled host and displayed on Remote Console In normal situation only changed parts of video will be packed and sent from GFC IPM switch for saving network bandwidth This function...

Страница 32: ...hange the Local Keyboard setting to the right language manually Hotkeys Opens a list of hotkeys defined before Choose one entry the command will be sent to the host system A confirmation dialog can be...

Страница 33: ...e compression quality depends on the video picture itself e g the number of the colors or the diversity of pixels The lower the compression quality the more data have to be sent and the longer it may...

Страница 34: ...e data rate is reduced less bits per color Furthermore the OPMA module will not have to do any video compression In total this will lead to less transfer time of the motion picture 5 4 2 Remote Consol...

Страница 35: ...e in brackets displays the compressed transfer rate Figure 5 16 Status line transfer rate For more information about Monitor Only and Exclusive Access settings see related sections CyberResearch KVM A...

Страница 36: ...igure 6 1 KVM Console To open the KVM console either click on the menu entry on the left or on the console picture on the right To refresh the picture click on the button Refresh GFC IPM CyberResearch...

Страница 37: ...identical to those of the web interface That means the user management of the Telnet interface is entirely controlled with the according functions of the web interface Once you have successfully logg...

Страница 38: ...passthrough mode for serial port 1 The key sequence esc exit switches back to the command mode 6 2 Romote Power Control This Power Control function will be provided in the near future 6 3 Virtual Medi...

Страница 39: ...age file is kept in the onboard memory of the GFC IPM switch until the end of the current session as you logged out or initiated a reboot of the GFC IPM switch 6 3 2 CD ROM Image Use Image on Windows...

Страница 40: ...ified image file is supposed to be accessible from the GFC IPM switch The information above has to be given from the point of view of the GFC IPM switch It is important to specify correct IP addresses...

Страница 41: ...t field Comment If necessary adjust the permissions button permissions Click OK to set the options for this share UNIX and UNIX like OS Sun Solaris and Linux If you like to access the share via SAMBA...

Страница 42: ...your needs input device etc MS Windows You can use the tool Raw Write for Windows It is included on the CD ROM shipped with GFC IPM switch Figure 6 12 RawWrite for Windows selection dialog From the me...

Страница 43: ...image file use your favorite CD imaging tool Copy the whole contents of the disc into one single image file on your hard disk For example with Nero you choose Copy and Backup Then navigate to the Copy...

Страница 44: ...s on a level which is far below the operating system That means that neither the local nor the remote operating system is aware that the drive is currently redirected actually This may lead to inconsi...

Страница 45: ...It is not possible to write on a redirected device Click Apply to submit your changes 6 3 3 1 Driver Installation Please follow the Drive Redirection Setup Wizard step by step to install the driver f...

Страница 46: ...rt Drive Redirection Figure 6 16 Drive Redirection dialog Drive to redirect Device This is the address either the DNS name or the IP address of the GFC IPM switch you would like to connect to GFC IPM...

Страница 47: ...te support means that the remote computer is allowed to write on your local drive As you can imagine this is very dangerous If both the remote and the local system try to write data on the same device...

Страница 48: ...should not be a serious problem when the note above is respected If the write support is enabled a drive which is not locked might be damaged by the Drive Redirection With the Disconnect button a conn...

Страница 49: ...system will hang on boot due to changes in the boot order or the boot manager LILO GRUB This case was reported for some Windows versions 2000 XP other OS might not be fully excluded This behavior depe...

Страница 50: ...field below Click Apply to submit your changes 6 4 2 Users and Groups Figure 6 19 Set User The GFC IPM switch comes with 1 pre configured user account that has fixed permissions The account super has...

Страница 51: ...Modify changes the dis played user settings To delete an user press the button Delete Note The GFC IPM is equipped with an host independent processor and memory unit which both have a limitation in t...

Страница 52: ...ined automatically from the available bandwidth and the current content of the video image Pre configured The pre configured settings deliver the best result because of optimized adjustment of compres...

Страница 53: ...is actually a Java Applet If you check this box for the first time on your administration system and the appropriate Java plug in is not already installed on your system it will be downloaded and inst...

Страница 54: ...Console is unconditionally catching this keystroke already Typical examples are Control Alt Delete on Windows and DOS what is always caught or Control Backspace on Unix or Unix like OS for terminatin...

Страница 55: ...as host interface then the card will select USB if available or otherwise falls back to PS 2 To get USB remote keyboard access during the boot process of the host the following conditions must be ful...

Страница 56: ...e acceleration and speed of the mouse during the mouse sync process Fixed mouse speed Use a direct translation of mouse movements between the local and the remote pointer You may also set a fixed scal...

Страница 57: ...amount of network traffic even if the display content is not really changing depending on the quality of the video input signal All in all the default setting should be suitable for most situations F...

Страница 58: ...in Table 4 1 Warning Changing the network settings of the GFC IPM switch might result in losing connection to it In case you change the settings remotely make sure that all the values are correct and...

Страница 59: ...be used Telnet port Port number at which the GFC IPM switch s Telnet server is listening If left empty the default value will be used Bandwidth limitation The maximum network traffic generated through...

Страница 60: ...ce www dyndns org can be used in the following scenario see Figure 6 26 Figure 6 26 Dynamic DNS Scenario The GFC IPM switch is reachable via the IP address of the DSL router which is dynamically assig...

Страница 61: ...ress Dynamic DNS server This is the server name where GFC IPM switch registers itself in regular intervals Currently this is a fixed setting since only dyndns org is supported for now DNS System Choos...

Страница 62: ...PM switch refer to the Section called Certificate KVM encryption This option controls the encryption of the RFB protocol RFB is used by the Remote Console to transmit both the screen data to the admin...

Страница 63: ...ation authority CA A certification authority verifies that you are the person who you claim you are and signs and issues a SSL certificate to you The following steps are necessary to create and instal...

Страница 64: ...re is no way to get it back In case you deleted it by mistake you have to repeat the three steps as described above Common name This is the network name of the GFC IPM switch once it is installed in t...

Страница 65: ...e USA Note the country code has to be entered in CAPITAL LETTERS Challenge Password Some certification authorities require a challenge password to authorize later changes on the certificate e g revoca...

Страница 66: ...than building up a dedicated point to point connection from your console computer to the GFC IPM switch In other words the GFC IPM switch acts as an Internet Service Provider ISP to which you can dia...

Страница 67: ...is a point to point IP connection virtually every IP address is possible but you must make sure it is not interfering with the IP settings of the GFC IPM switch and your console computer The default...

Страница 68: ...FC IPM switch loses power for more than a few minutes To avoid this you can use a NTP timeserver which sets up the internal clock automatically to the current UTC time Because NTP server time is alway...

Страница 69: ...w many log entries are shown on each page Furthermore you can clear the log file here List logging enabled The common way to log events is to use the internal log list of the GFC IPM switch To show th...

Страница 70: ...the mail subject is filled with the event group of the occurred log event In order to use this log destination you have to specify a SMTP server that has to be reachable from the GFC IPM switch devic...

Страница 71: ...or move it away from time to time 6 7 Maintenance 6 7 1 Device Information Figure 6 34 Device Information Device Summary This section contains a summary with various information about this GFC IPM swi...

Страница 72: ...Remote Console is open If the Remote Console is opened in exclusive mode the term exclusive mode is added For more information about this option see the Section called Remote Console Control Bar in Ch...

Страница 73: ...o be accessible on the system that you use for connecting to the GFC IPM switch Updating the firmware is a three stage process Firstly the new firmware file is uploaded onto the GFC IPM switch In orde...

Страница 74: ...d staff members or administrators should perform a firmware update Make sure the GFC IPM switch s power supply will not be interrupted 6 7 4 Unit Reset Figure 6 38 Unit Reset This section allows you t...

Страница 75: ...working in general ping the IP address of GFC IPM switch If not check network hardware Is GFC IPM switch powered on Check whether the IP address of GFC IPM switch and all other IP related settings are...

Страница 76: ...move mouse pointer to the default button of dialog boxes enabled in the mouse settings of the operating system This option needs to be disabled 8 FAQs The color of remote console displaying a pinkish...

Страница 77: ...an work with most standard KVM How many letters the username and password can be set on GFC IPM switch The GFC IPM switch accepts 32 letters of username and password How many concurrent user of GFC IP...

Страница 78: ...English language mapping The layout for this keyboard is shown in Figure A 1 However most modifier keys and other alphanumeric keys used for hotkey purposes in application programs are on an identical...

Страница 79: ...BREAK INSERT HOME PAGE UP DELETE END PAGE DOWN UP LEFT DOWN RIGHT NUM LOCK NUMPAD0 NUMPAD1 NUMPAD2 NUMPAD3 NUMPAD4 NUMPAD5 NUMPAD6 NUMPAD7 NUMPAD8 NUMPAD9 NUMPADPLUS NUMPAD PLUS NUMPAD NUMPADMUL NUMP...

Страница 80: ...detect them Resolution x y Refresh Rates Hz 640 x 350 70 85 640 x 400 56 70 85 640 x 480 60 72 75 85 90 100 120 720 x 400 70 85 800 x 600 56 60 70 72 75 85 90 100 832 x 624 75 1024 x 768 60 70 72 75 8...

Страница 81: ...irmware x Maintenance Unit Reset Keyboard Mouse Video Keyboard Mouse Video Keyboard Mouse Video Device Table C 1 User Role Permissions D GFC IPM switch port table Port Protocol Purpose 23 Telnet over...

Страница 82: ...bit 3 0 3 3 MB s uncompressed synchronized video data most bandwidth needed Video Optimized high color Video Optimized 16 bit 4 3 5 0 MB s uncompressed synchronized video data most bandwidth needed L...

Страница 83: ...Male to Male USB 2 0 Cable USB A B cable CAT5 5E 6 Straight Through UTP STP Cable 8P8C CyberResearch KVM Accessories GFC IPM CyberResearch Inc 81 25 Business Park Drive P 203 643 5000 F 203 643 5001 B...

Страница 84: ...nce 2 This device must accept any interference received including interference that may cause undesired operation CE This equipment is in compliance with the requirements of the following regulations...

Страница 85: ...ts of the signals you are trying to measure as well as the signals on the board module or power supply 4 Isolate problem areas that are not working as you expected 5 Have the source code to the progra...

Страница 86: ...GFC IPM CyberResearch KVM Accessories Intentionally Blank 84 Copyright 2009 CyberResearch Inc...

Страница 87: ...ed and in lieu of all other warranties expressed implied or statutory including but not limited to any implied warranty of merchant ability or fitness and all other obligations or liabilities of selle...

Страница 88: ...GFC IPM CyberResearch KVM Accessories Intentionally Blank 86 Copyright 2009 CyberResearch Inc...

Страница 89: ......

Страница 90: ...CyberResearch Inc 25 Business Park Drive Branford CT 06405 USA P 203 643 5000 F 203 643 5001 www cyberresearch com...

Отзывы: