background image

Model Number

CS24U12V

CS24U12V-12 CS24C12V2-E CS24U12V-XL CS30U12V-20

CS16U48V-8

CS50U48V

CS36A12V2*

CS20A-EBP

Area of use

Interior

Interior

Exterior

Interior

Interior

Interior

Interior

Interior

Interior

RoHS Compliant

Yes

Yes

Yes

Yes

Yes

Yes

Yes

No

Yes

Voltage Range

90Vac - 135Vac

-

Frequency Range

60Hz

-

On Battery Output Voltage

12Vdc - 17Vdc

-

Continuous Power Capability

30W

16W

50W

36W

-

Output Power Maximum

30W

16W

50W

36W

-

Efficiency (at Max Load)

-

Sealed, Maintenance Free 

Lead-Acid Battery

7.2AH/12V

12AH/12V

7.2AH/12V

7.2AH/12V

20AH/12V

8AH/12V

20AH/12V

N/A

20AH/12V

Intelligent Charging

N/A

-

Typical Battery Life

3 - 5 years

3 - 5 years

3 - 5 years

5 - 8 years

5 - 8 years

3 - 5 years

5 - 8 years

N/A

5 - 8 years

Typical Recharge Time

18 Hours

24 Hours

18 Hours

18 Hours

42 Hours

12 Hours

18 Hours

N/A

-

User Replaceable

-

Audible Indicator

-

LED Indicators

-

Auto-Charge

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

-

Communication Interface

-

Operating Temperature

-4°F to 115°F (-20°C to 46°C)

-

Operating Humidity

-

Maximum Operating Elevation

-

Storage Temperature

-

Maximum Storage Elevation

10,000ft (3,000m)

-

Power Cords

Pass-Through

Pass-Through

Non-Pass Through

Pass-Through

Non-Pass Through

Pass-Through

Non-Pass Through

Non-Pass Through

Non-Pass Through

Unit Dimensions (in)

9¼  x 6¼  x 3½  9¼  x 6¼  x 4½  10¾  x 8  x 3¾  9¼  x 6¼  x 3½  11¾ x 11 x 4 9¼  x 6¼  x 3½  11¾ x 11 x 4

PSU - 4x2½x1½

BBU - 6¾x6¾x3½

11¾ x 11 x 4

Unit Weight (lbs)

7.3

10.8

7.7

7.3

17

7.3

17.5

PSU - .77

BBU - 1.51

15.4

Carton Dimensions (in)

14 x 14 x 4¾

14 x 14 x 6½

14 x 14 x 4¾

14 x 14 x 4¾

17 x 17¼ x 9

14 x 14 x 4¾

17 x 17¼ x 9

7¼x11¾x9¼

17 x 17¼ x 9

Carton Weight (lbs)

9.5

13.0

10.0

9.5

21.0

9.5

22.0

3.3

20.0

*CS36A12V2 unit does not ship with a battery.  Unit takes a 7.2AH battery
**Exterior unit electronics operating temperature is -40°F to 131°F (-40°C to 46°C) + solar loading.  Battery has a trickle charge in lieu of a battery heater

10,000ft (3,000m)

Environment

Physical

50,000ft (15,000m)

5°F to 113°F (-15°C to 45°C)

32°F to 104°F (0°C to 40°C)**

Warning Diagnostics

Management

 0% - 95% condensing

Yes, Hot Swappable

Utility Failure, Low Battery

AC, Output, Battery

On Battery, Replace Battery, Battery Missing, Low Battery

Flexible

Input

Output

Unit evaluates battery temperature and adjusts the charging cycle accordingly

87Vac - 264Vac (Universal Input)

40 - 70 Hz

Battery

12Vdc

48Vdc

24W

24W

> 76%