SPECIFICATIONS 

 

CPS325SL 

Capacity 

325VA(185W) 

Input Voltage on Utility 

100V to 140V 

Input Frequency 

57 Hz to 63 Hz 

On-Battery Output Voltage 

120Vac ± 5% 

Transfer Time 

4ms Typical 

Max. Load for UPS Outlets (3 Outlets) 

325VA  (185W) 

Max. Load for Full-Time Surge Protec-
tion outlets (6 Outlets) 

 

10 Amps 

On-Battery Output Wave Form 

Simulated Sine Wave Form 

Operating Temperature 

+ 32°F to 95° F. (0° C to 35° C) 

Operating Relative Humidity 

0 to 95% NON-CONDENSING 

Size (Length x Width x Height) 

9 7/8” x 6 3/16” x 3 1/8” (24.9cm x 12.0cm x 8.0cm) 

Net Weight 

7.4 pounds (3.4Kg) 

Typical Battery Recharge Time 

8 hours typical from total discharge 

Typical Battery Life 

3 to 6 years, depending on number of discharge/recharge cycles 

Battery Type 

12V / 3.0AH 

Recommended Battery 

Spill-proof, Maintenance-free, sealed lead-acid 

Safety Approvals 

UL1778(UPS), CUL107.1/FCC/DoC Class B 

 

EXPECTED RUNTIME IN MINUTES 

 

CPS325SL CPS375SL CPS575SL CPS650SL 

Desktop PC with 
15” Monitor 

6 – 9 

8 – 12 

17 – 21 

18 – 22 

 

Desktop PC with 
17” Monitor 

4 – 6 

6 - 9 

15 – 19 

16 – 20 

Desktop PC with 
21” Monitor 

Not Advised 

(> 1 min.) 

Not Advised 

(> 2 min.) 

13 – 17 

14 – 18 

 

Содержание CPS325SL

Страница 1: ...al appli cations DO NOT use in any circumstance that would affect operation or safety of any life support equipment or with any medical applications or patient care DO NOT USE WITH OR NEAR AQUARIUMS T...

Страница 2: ...omputer system will re quire The total load that you will be placing on the battery powered outlets should not exceed 80 of the unit s capacity Hardware Installation Guide 1 Your new UPS may be used i...

Страница 3: ...o the UPS and an open serial port on the back of the com puter Note You must use the serial cable that was supplied with the unit 3 Plug the UPS into an AC outlet turn the UPS on and then start your c...

Страница 4: ...greater is designed for use with Windows 95 Windows 98 Windows Me Windows NT and Windows 2000 The latest version can be downloaded from www cyberpowersystems com downloads htm It works in conjunction...

Страница 5: ...start the shut down process If the low battery condition is met before this timer reaches zero the software will start the shutdown process 4 UPS is Installed On This shows the current COM port that t...

Страница 6: ...service instead of PowerPanel You can run either PowerPanel or the Windows 2000 UPS service but not both To Configure the Windows 2000 UPS Service 1 Click on Start point to Settings then Control Panel...

Страница 7: ...rdinances regarding proper disposal of batteries CAUTION Do not open or mutilate the batteries Released electrolyte is harmful to skin and eyes and may be toxic CAUTION A battery can present a high ri...

Страница 8: ...will run out of power shortly Off Up Two Beeps or Rapid Beeps System Overload Occurs when connected equip ment exceeds the rating of unit Turn the UPS off unplug at least one piece of equipment wait...

Страница 9: ...ast 24 hours Please leave the unit plugged into an AC outlet and don t turn on the power switch The unit will charge in off position The battery is worn out Contact CyberPower Systems about replacemen...

Страница 10: ...NSING Size Length x Width x Height 9 7 8 x 6 3 16 x 3 1 8 24 9cm x 12 0cm x 8 0cm Net Weight 7 4 pounds 3 4Kg Typical Battery Recharge Time 8 hours typical from total discharge Typical Battery Life 3...

Страница 11: ...Warranty Limited Warranty CyberPower warrants to you the Initial Purchaser that the Product will be free from defects in material and workmanship for three years from the date of original purchase sub...

Страница 12: ...urance or other re sources of recovery payment that are available to the Initial Customer for the Connected Equipment and the name of the power utility supplier for the location of the Connected Equip...

Страница 13: ...roperly installed and connected This exclusion applies for example to fluctuations in data transmission or reception by CATV or RF transmis sion or fluctuations or by transients in such transmission D...

Отзывы: