Guaranteed Uninterruptible Power System
TO REPLACE THE BATTERY
1.
Turn off and unplug all connected equipment.
2.
Turn the UPS off and unplug it from the AC power source.
3.
Turn the UPS upside down.
4.
Remove the 6 retaining screws.
5.
Turn the UPS right side up and remove the outlet cover.
6.
Remove the battery from the compartment.
7.
Disconnect the battery wires from the battery.
8.
Install the replacement battery by connecting the
red wire to the positive (+) terminal of the battery
and
connecting the
black wire to the negative (-) terminal of the battery.
9.
Slide the battery back into the compartment.
10.
Replace the outlet cover and the 6 retaining screws.
11.
Recharge the unit for 4 – 8 hours to ensure the UPS performs expected runtime.
REMINDER:
Batteries are consider
HAZARDOUS WASTE
and must be disposed properly. Contact your local
government for more information about proper disposal and recycling of batteries.