Replacing Leveling Feet
➢
To replace leveling feet
1. Using a forklift, raise the SE500
ULTRA
frame off the floor.
2. Remove the two M8 screws that secure the plate and foot assembly to the frame.
3. Replace the damaged leveling foot.
4. Reassemble the foot assembly onto the frame.
5. Repeat steps 1– 4 as required to replace the other leveling feet.
6. Adjust the leveling feet as needed to align the SE500
ULTRA
with the conveyors. For more
information, refer to the section “
Positioning / Leveling the SE500ULTRA
” on page 28 for
details.
Figure 98.
Leveling Foot
Locking nut
Adjustment nut