MedStar Unit User’s Manual 

Model 533-210

 

Cybernet Medical 

 

Confidential Information 

 

 

Page 1 of 1 

Содержание MedStar 533-210

Страница 1: ...MedStar Unit User s Manual Model 533 210 Cybernet Medical Confidential Information Page 1 of 1 ...

Страница 2: ...uctions 8 Distributor Instructions 8 Programming Instructions 10 Operating and Storage Conditions 15 FCC Registration and Repair Information 17 FEATURES Text Display Activation Button Scale Interface Blood Pressure Interface Pulse Oximeter Interface Spirometer Interface Phone Interfaces Cybernet Medical Confidential Information Page 2 of 2 ...

Страница 3: ...t end to the GREEN interface socket on the MedStar device Connecting MedStar to the Pulse Oximeter To Pulse Oximeter Unit Connect one end of the BLACK cable to the Pulse Oximeter Unit and the other end to the BLACK interface socket on the MedStar device Connecting MedStar to the Blood Pressure Unit Cybernet Medical Confidential Information Page 3 of 3 ...

Страница 4: ...interface socket on the MedStar device Connecting MedStar to the Spirometer To Spirometer Unit Connect one end of the YELLOW cable to the Spirometer unit and the other end to the YELLOW interface socket on the MedStar device Connecting MedStar to the phone line Cybernet Medical Confidential Information Page 4 of 4 ...

Страница 5: ... in the setup instructions above Note the MedStar device does not need to be turned on it will wake up when the connected weight scale is activated 2 First take blood pressure measurement according to the instructions that accompany the blood pressure unit Place cuff on arm and press blue button on the Blood Pressure unit Make sure you read the measurement results so that you are aware of your val...

Страница 6: ...ser to turn on the PalmSat Pulse Oximeter unit The user should then follow the instructions that accompany the PalmSat unit to take a pulse oximeter reading After the Pulse Oximeter measurement has been taken the MedStar will attempt to query the Spirometer make sure the spirometer is in data mode as described in step 3 above Next the MedStar will proceed to collect all data stored on the blood pr...

Страница 7: ...connect the spirometer unit from the MedStar device by removing the cable and take the spirometer device along wherever you go 2 Take one or more spirometer measurements throughout the day These measurements get stored in the spirometer unit see the spirometer unit manual for maximum number of readings that may be stored 3 Reconnect the spirometer unit to the MedStar device using the appropriate c...

Страница 8: ...D Medical UA 767PC Weight Scale A D Medical UC 300 A D Medical UC 321 Pulse Oximiter Nonin PalmSat 2500 Spirometer Ferraris KoKo Peak Pro 6 DISTRIBUTOR INSTRUCTIONS Caution Federal law restricts this device to sale by or on the order of a physician Warning The MedStar Unit is designed to be used only by a single patient at a time If there are more than one patient each using their own MedStar Unit...

Страница 9: ...one patient to appear as if it belongs to another It is intended for more general identification such as the patient s disease state Using the Device Code to identify MedStar Users may place your system in non compliance with some medical regulations Each MedStar Unit comes with a pre set default phone number and phone number prefix programmed See the section Programming Instructions for informati...

Страница 10: ...he upper recessed button While holding the upper recessed button press and release the activation button Keep the upper recessed button pressed until the Device Setup message appears Once in programming mode use the recessed button to advance through the device setup options Each option is described next in the order they appear Code Version Provides a display of the software version installed on ...

Страница 11: ... to cancel or accept the new value Cancel using the lower recessed button Accept using the activation button Test the Phone Connection 6 Now at the message Connect to Phone Line press the activation button Messages will indicate status of the call and whether it passed or failed 7 Once the test is complete press the activation button to return to the device setup options If the test fails you will...

Страница 12: ...tion for more information To change the Device Code press the activation button when this option is selected Set the Device Code value using the upper recessed button to scroll forward the lower recessed button to scroll backward and the activation button to increment the selected digit Once the value is set as desired scroll forward past the last digit The Server Code will then be displayed with ...

Страница 13: ...uccessful operation They require no action Message Description Dialing MedStar is dialing phone number for connection to Data Collection Server Line Busy Phone line is Busy MedStar will wait several minutes and attempt to try again After several attempts it will shutdown and store data for transmission with the next collection No Data to Transmit MedStar has no collected data to transmit It will s...

Страница 14: ...udio beeps or longer low frequency audio tones Action may need to be taken in order to establish proper operation Message Description Auth Err Call TechnicalSupport An error occurred during security authentication with the Data Collection Server User must call technical support to restore operation Deny Err Call TechnicalSupport MedStar did not pass security authentication with the Data Collection...

Страница 15: ...l tone on the phone line Connection to the Data Collection Server cannot be established The user should confirm proper connection between the MedStar and the phone outlet If the error still occurs then the user should contact technical support Please Check BP Device and Cable MedStar cannot establish communication with the Blood Pressure device The user should confirm proper connection between the...

Страница 16: ...h water or other liquid Electromagnetic Interference MedStar should not be operated in close proximity to any large electrical appliances or industrial equipment that could generate significant electromagnetic interference Cables Use only with supplied cables Cleaning Instructions Remove the batteries and unplug all cables from the MedStar before cleaning The MedStar can be cleaned with a clean sl...

Страница 17: ...light for prolonged periods of time Do not apply pressure to the display panel The MedStar should not be exposed to highly humid environments for prolonged periods of time Do not attempt to disassemble the MedStar for any reason Cybernet Medical Confidential Information Page 17 of 17 ...

Страница 18: ...ontact the local telephone company If this device causes harm to the telephone network the telephone company will notify you in advance that temporary discontinuance of service may be required But if advance notice isn t practical the telephone company will notify the customer as soon as possible Also you will be advised of your right to file a complaint with the FCC if you believe it is necessary...