Quick Reference
930945A
© 2014, CyberData Corporation, ALL RIGHTS RESERVED
© 2014, CyberData Corporation, ALL RIGHTS RESERVED
930945A
Quick Reference
Wall Mounting Options
Gang Box Mounting Options
Backplate
Wall
(Not Provided)
Network Cable &
Screw
121001A
Accessory Kit
(4 Places) on Wall
Pre Drill Holes
Ground Wire
Cutout
for Ground Wire Connection
Pick One of Four Mounting Hole
Mounting
Screw (3x)
Slot
Entry
Cable
Closed
Slots
Cable
Two Gang Box use four
Wall Cutout
or Two Gang Box
Backplate accept
Single Gang Box
Single Gang Box use two
Backplate
Wall Cutout
121002B
Screw Accessory Kit
Mounting
Screw (3x)
(Not Provided)
Ground Wire
Any Available Mounting Hole
Ground Wire Connect to
(Not Provided)
Network Cable
Slot
Entry
Cable
Closed
Slots
Cable
Getting Started
•
Download the Operations Guide PDF file from the following web page:
http://www.cyberdata.net/products/voip/digitalanalog/singlewireemergencyintercom/docs.html
•
Create a plan for the locations of your Intercoms.
•
WARNING: This product should be installed by a licensed electrician according to all local electrical and building codes.
•
WARNING: To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation
instructions.
•
WARNING: The PoE connector is intended for intra-building connections only and does not route to the outside plant.
•
WARNING: This enclosure is not rated for any AC voltages!
Parts
Contacting CyberData
Parameter
Factory Default Setting
IP Addressing
DHCP
IP Address
a
a. Default if there is not a DHCP server present.
10.10.10.10
Web Access Username
admin
Web Access Password
admin
Subnet Mask
a
255.0.0.0
Default Gateway
a
10.0.0.1
(4) Plastic Ribbed Anchor
(4) #6-32 FlatHead Countersunk
Machine Screw
(1) Wall Mounting Kit
(1) Intercom Assembly
(1) Gang Box Mounting Kit
(4) Sheet Metal Screw
The IP Endpoint Compan
y
Installation Quick Reference
Singlewire-enabled
VoIP Emergency Intercom
011304