Cyber Power BP36V60ART2U Скачать руководство пользователя страница 13

 

Copyright ©  2020 Cyber Power Systems, Inc.

 

LIMITED WARRANTY

 

 

 

 

 

12 

 

Who Pays For Shipping?

 

We pay when we send items to you; you pay when you send items to us. 

What Are Some Examples Of What This Warranty Does Not Cover?

 

1. This Warranty does not cover any software that was damaged or needs to be replaced due to the failure of the Product or any data that is lost as a result of 
the failure or the restoration of data or records, or the reinstallation of software. 

2.  This  Warranty  does  not  cover  or  apply  to:  misuse,  modification,  operation  or  storage  outside  environmental  limits  of  the  Product  or  the  equipment 
connected to it, nor for damage while in transit or in storage, nor if there has been improper operation  or maintenance, or use with items not designed or 
intended for use with the Product, such as laser printers, appliances, aquariums, medical or life support devices, etc.

 

What Other Limitations Apply? 

The sole and exclusive remedies of the Initial Customer are those provided by this Warranty. 

1. This Warranty does not apply unless the Product  and the  equipment  that was connected to it were connected to properly  wired and grounded outlets 
(including compliance with electrical and safety codes of the most current electrical code), without the use of any adapters or other connectors. 

2. The Product must have been plugged directly into the power source and the equipment connected to the Product must be directly connected to the Product 
and not “daisy-chained” together in serial fashion with any extension cords, another Product or device similar to the Product, surge suppressor, or power tap. 
Any such installation voids the Limited Warranty. 

3. The Product must have been used properly in a suitable and proper environment and in conformance with any license, instruction manual, or warnings 
provided with the Product and the equipment connected to it. 

4. The Product must have been used at all times within the limitations on the Product’s VA capacity. 

The Product was designed to eliminate disrupting and damaging effects of momentary (less than 1ms) voltage spikes or impulses from lightning or other 
power transients. If it can be shown that a voltage spike lasting longer than 1ms has occurred, the occurrence will be deemed outside the rated capabilities of 
the Product and the Limited Warranty is void. CyberPower Does Not Cover or Undertake Any Liability in Any Event for Any of the Following: 

1. Loss of or damage to data, records, or software or the restoration of data or records, or the reinstallation of software. 

2. Damage from causes other than AC Power Line Transients, spikes, or surges on properly installed, grounded and code-compliant 120 volt power lines in 
the United States and Canada; transients, surges or spikes on standard telephone land lines, PBX telephone equipment lines or Base 10T Ethernetlines, 
when properly installed and connected. (This exclusion applies, for example, to fluctuations in data transmission or reception, by CATV or RF transmission or 
fluctuations, or by transients in such transmission.) 

3. Damage from any circumstance described as excluded above with respect to the Product. 

4. Damages from fire, flood, wind, rain, rising water, leakage or breakage of plumbing, abuse, misuse or alteration of the product. 

5. CyberPower excludes any liability for personal injury under the Limited Warranty. CyberPower excludes any liability for direct, indirect, special, incidental or 
consequential damages, whether for damage to or loss of property [EXCEPT FOR (AND ONLY FOR) the specific limited agreement of CyberPower to provide 
certain warranty benefits, loss of profits, business interruption, or loss of information or data. NOTE: Some States or Provinces do not allow the exclusion or 
limitation of incidental or consequential damages, so the above limitation may not apply to you. 

6. The Product is not for use in high-risk activities or with aquariums. The Product is not designed or intended for use in hazardous environments requiring 
fail-safe performance, or for use in any circumstance in which the failure of the Product could lead directly to death, personal injury, or severe physical or 
property damage, or that would affect operation or safety of any medical or life support device (collectively, "High Risk Activities"). CyberPower expressly 
disclaims any express or implied warranty of fitness for High Risk Activities or with aquariums. CyberPower does not authorize use of any Product in any High 
Risk Activities or with Aquariums. 

ANY SUCH USE IS IMPROPER AND IS A MISUSE OF THE PRODUCT.

 

Where Can I Get More Information?

 

The application of the United Nations Convention of Contracts for the International Sale of Goods is expressly excluded. 

CyberPower is the warrantor under this Limited Warranty. 

For further information please feel free to contact CyberPower at 

Cyber Power Systems (USA), Inc. | 4241 12th Ave E., STE 400, Shakopee, MN 55379 

(877) 297-6937 | [email protected]

Содержание BP36V60ART2U

Страница 1: ... EXTENDED BATTERY MODULE EBM BP36V60ART2U BP72V60ART2U Cyber Power Systems USA Inc 4241 12th Avenue East Suite 400 Shakopee MN 55379 Phone 877 297 6937 Fax 952 403 0009 http www cyberpowersystems com K01 0000515 03 ...

Страница 2: ...connection Additional parallel connected EBM provide the UPS for a longer extended runtime operation 1K 1 5KVA or 2K 3KVA extended battery module User s manual Register card Rackmount left rail Rackmount right rail Left hanging bracket Right hanging bracket IEC320 C14 to NEMA 5 15P power cord Rackmount ears Stands 2 Tie plate 1 M5X7L black flat head screws 8 M5X12L black pan head screws 12 M5X6L s...

Страница 3: ...the mounting brackets RACKMOUNT INSTALLATION FOR 4 POST RACK Step 1 Remove the dust covers Remove the dust covers 5 pcs from the screw holes Step 2 Rackmount ears hanging brackets installation Attach two rackmount ears to the EBM using the provided M5X7L 8pcs screws and tighten two hanging brackets with the M5X6L 6pcs screws Step 3 Rackmount rail Installation The rails adjust to mount in 48 cm 19 ...

Страница 4: ... the rear of the rack with two M5X12L screws and two plastic washers Step 5 Place and secure the EBM on the rails Slide the hanging brackets on the EBM into the rails mounted in the rack with the front of the unit facing toward you Secure the EBM to your rack with four M5X12L 4pcs screws at the front of the rack Located in position 2 position 5 How to slide the EBM out from the rack The EBM will b...

Страница 5: ... strongly recommend having 2 3 people assist during the installation process CAUTION It is strongly recommended that the 2 post rack be bolted to the floor prior to the installation of the EBM Step 1 Remove side dust covers Remove seven dust covers from screw holes as shown below Step 2 Rackmount ears installation Attach the included rackmount ears to the center holes on the sides of the EBMEBM us...

Страница 6: ...ew the upper panel of the UPS Separate the upper panel from the UPS Gently lift the LCD module out Rotate it to the tower orientation Reinstall it for a tower configuration SAFETY PRECAUTIONS CAUTION Installation environment should be in a temperature and humidity controlled indoor area free of conductive contaminants Do not install this EBM where excessive moisture or heat is present Please see s...

Страница 7: ... EBM upstream 5 Input Connector Use this input connector to daisy chain the next EBM Remove the connector cover for access 6 Output Cable Use this output cable to connect the EBM to the UPS or to the next EBM 7 DC Breaker Use the DC breaker to disconnect battery output BP36V60ART2U BP72V60ART2U CONNECTION 1 UPS WITH ONE EXTENDED BATTERY MODULE Step 1 Turn off the DC breaker of the EBM Step 2 Loose...

Страница 8: ...ry cable retention bracket and tighten the two screws to fix battery cable Step 6 Use a power cord to plug AC input inlet of the 2nd EBM into AC output outlet of the 1st EBM Step 7 Turn on the DC breaker of the 2nd Battery module Step 8 Set the EBM number to the respective setting to match the number of installed units To do this via the LCD control panel go to the Configuration Menu then scroll t...

Страница 9: ...ect the Configure submenu 4 Press the and buttons to scroll to the EBM Number option 5 Press the ENTER button to select the EBM Number submenu The first configuration number will be displayed on the second column of LCD display 6 Press the and buttons to scroll through the number of attached EBM 7 Press the ENTER button to select the number of EBM installed You may be prompted to save the selectio...

Страница 10: ...Replacement Batteries Please refer to the front side of the EBM for the model number of the correct replacement batteries For battery procurement log onto www cyberpowersystems com or contact your local dealer Battery Disposal Batteries are considered hazardous waste and must be disposed of properly Contact your local government for more information about proper disposal and recycling of batteries...

Страница 11: ...ltage 100 125Vac DC Output Voltage 36Vdc 72Vdc DC Output Current 60A Physical Dimensions L x W x H 16 9 x 17 x 3 5in 430 x 433 x 88mm 23 6 x 17 x 3 5in 600 x 433 x 88mm Net Weight 50 6lbs 23 0Kg 96 8lbs 44 0Kg Battery Specifications 6 12V9AH 2 x Banks of 3 Batteries 12 12V9AH 2 x Banks of 6 Batteries Replacement Battery Cartridge 1 RB1290X3L 1 RB1290X3R 2 RB1290X6B Recharge Time 0 90 Typical 4 hou...

Страница 12: ...ervice 1 Before contacting CyberPower identify Your Product model number and the Purchase Date 2 Email us at tech cpsww com or Call us at 877 297 6937 3 If your product requires warranty service you must provide a copy of your dated purchase receipt or invoice How Do You Open A Warranty Claim 1 Call us at 877 297 6937 or write to us at Cyber Power Systems USA Inc 4241 12th Ave E STE 400 Shakopee M...

Страница 13: ...take Any Liability in Any Event for Any of the Following 1 Loss of or damage to data records or software or the restoration of data or records or the reinstallation of software 2 Damage from causes other than AC Power Line Transients spikes or surges on properly installed grounded and code compliant 120 volt power lines in the United States and Canada transients surges or spikes on standard teleph...

Страница 14: ...no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the ...

Отзывы: