![CYBELEC CybTouch 6 G Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/cybelec/cybtouch-6-g/cybtouch-6-g_user-manual_2701328017.webp)
v2.4c
03.04.12
CybTouch6_Shear_Usermanual_v2.4c_TK
page 17 of 18
I
NFORMATION AND
E
RROR
M
ESSAGES
Below is a list of warning and error messages which may be displayed in the
interactive message line:
Information messages are on a green background, they will disappear
automatically.
Error messages (machine or NC errors) are on a red background. They inform
the user of an error occurring on the machine or NC, and sometimes require
intervention by the end user or a technician.
INFORMATION MESSAGES
10 //
Döngü işlemde
The operator touched the screen while a cycle is running (the screen is inactive
except the STOP button).
15 //
Otomatik Kesim girişi
yok
The automatic cut input is configured but not active. It must be active to enable
the AutoCut function in the EasyCut page. Usually a switch or key switch is used
to enable this function.
18 //
Boş Alan
Operator did not enter a value.
19 //
G/Ç İçin 24V Besleme
Gerilimi Aktif
24V to the inputs/outputs is now available.
29 //Liste Sonu
End of list reached. Scroll backwards.
32 //
Veri girişi devam
ediyor…
Operation impossible: data entry in progress. Please finish entering data and try
again.
35 //
Erişime izin yok
Operator needs to enter a different password.
43 //
"OGG hazır" girişi
bekleniyor
A switch makes sure the sheet support is in the correct position for the operator to
move the backgauge to retrieve the cut part. Check the sheet support position, it
must be fully up. Otherwise check the RTS switch.
44 //
AsgAÖN sınıra ulaşıldı
Minimum BDC limit has been reached, down stroke has been stopped. This may
occur in manual mode. If this message appears often In normal cutting operation,
the machine parameters need to be readjusted.
ERROR MESSAGES
03 //Buffer Full
The part-program memory is full, cannot add another sequence.
04 //Kod Kabul Edilmedi
The password to access the selected page is not correct. Enter the correct
password.
05 //
Dosya Uyumlu Değil
The loaded part-program is incompatible with the NC. This part should be deleted.
06 //Makine parametresi
dosya hatası
This file is corrupt. Try to restart the NC. If the problem persists, format the
memory.
Before formatting memory, make sure with your dealer that original parameters
backup is available.
07 //Makine parametresi
uyumsuz, lütfen diski
biçimlendirin.
A software update has been made over a much older version, the original
parameters are no longer compatible. Or uploaded parameters (with RFlink) are
much older or newer than the current software version, and are not compatible. A
new start up of the machine must be made. Contact your dealer.
11 //Dosyaya Yazma Sorunu
This file is corrupt and cannot be saved. Try to restart the NC. If the problem
persists, format the memory.
Before formatting memory, make sure with your dealer that original parameters
backup is available.
12 //
X asgari sınırın altında
The operator entered a value under the limit or a memorized value in the program
is under the limit. Change value.
13 //
X azami sınırın üzerinde The operator entered a value over the limit or a memorized value in the program
is over the limit. Change value.
15 //
"AÖN asg" girişi aktif
Min BDC has been reached, cannot descend more.