Cyano Cyano-RF Скачать руководство пользователя страница 5

It  is  highly  recommended  to  check  own  physical  status,  and  have  enough  rest.

CYANO  calculation  of  sport  diving  maximum  of  depth  is  based  on  O₂%  and  set  from  1.4bar  of  maximum  oxygen  partial  pressure  (PO₂)  set  point,  and  it  is  also 

strongly  advised  to  restrict  to  dive  within  40m  of  depth  that  is  calculated  from  dive  computer.

It  is  advised  to  quit  diving  when  decompression  stop  is  needed.  when  display  shows  decompression  stop,  ascent  should  be  started  immediately  and  also 
decompression  stop  has  to  be  done  as  directed.

Use  BACK-UP  gauge.  Ensure  that  you  use  depth  gauge,  submersible  pressure  gauge,  timer  or  watch,  and  have  access  to  decompression  tables  whenever  diving 
with  the  dive  computer.

PERFORM  PRE-CHECKS!  Always  activate  and  check  the  device  before  diving  in  order  to  ensure  that  all  LCD  segments  are  completely  displayed,  the  device  has  not 

run  out  of  battery  power,  and  that  the  oxygen,  altitude,  personal,  and  other  functional  settings  state.

It  is  strongly  recommend  you  to  charge  the  dive  computer  when  you  dive  again  after  the  previous  diving.

When  battery  has  been  discharged,  decompression  information  of  repetitive  diving  and  previous  diving,  and  other  data  remain  and  optimal  algorithm  cannot  be 

applied.  This  problem  possibly  lead  to  the  danger  of  providing  inaccurate  decompression  information,  and  so  prohibit  to  follow  the  information  shown  on  dive 

computer.

Please  check  out  no-fly  time  before  boarding  on  airplane  after  diving.  Travelling  high  altitude  or  flying  after  diving  and  while  no-flying  symbol  is  still  on  the 
display  can  increase  the  risk  of  decompression  illness.  If  no-flying  related  regulation  is  violated,  risk  of  occurring  decompression  illness  cannot  be  fully  prevented.

Содержание Cyano-RF

Страница 1: ...and GPS 3 3 6 Setting up Display brightness 3 3 7 Bluetooth on off 3 3 8 Guage mode on off 3 3 9 Setting up condition 3 3 10 Sleep Time 3 3 11 Buzzer ON OFF 3 3 12 Compass Calibration 4 Before diving 4 1 Buhlmann ZH L16C algorithm 4 2 Emergency ascent 4 3 limitations of Dive computer 4 4 Nitrox 4 5 Free diving 4 6 Audible visual alarms 4 7 Activating diving mode 4 7 1 Setting up NITROX mode 4 8 pr...

Страница 2: ...fore starting Nitrox dive 6 3 Dive with GUAGE mode Dive Gauge 7 After Diving 7 1 Surface Interval 7 2 Diving frequency 7 3 Flying after diving 7 4 LOG MODE 7 5 Exclusive APP for CYANO 7 6 No Dive Mode 8 CARE AND MAINTENANCE 8 1 Buttons 8 2 Maintaining dive computer 8 3 Maintenance 8 4 Waterproof test 9 Replacing battery 10 Technical data 10 1 Technical specifications 11 Copyright Trademark Patent ...

Страница 3: ...ew for high readability in deep sea It is installed with bluetooth 4 1 to be connected with exclusive smart phone app to manage dive log share SNS and adjust device settings as well Furthermore its wireless charging system makes provide convenience of charging and leakage accident prevention caused while replacing battery slide type strap changing method improves compatibility and varies your choi...

Страница 4: ...ighly exposed to danger of decompression illness or can exceed acceptable critical water depth For these reasons CYANO advise not to use the gear for commercial or technical diving Only trained divers should use this device Not any dive computer can replace the need for proper dive training Inappropriate diving may cause serious injuries to deadly situation Whether diving plan shows on dive comput...

Страница 5: ...fore diving in order to ensure that all LCD segments are completely displayed the device has not run out of battery power and that the oxygen altitude personal and other functional settings state It is strongly recommend you to charge the dive computer when you dive again after the previous diving When battery has been discharged decompression information of repetitive diving and previous diving a...

Страница 6: ...ect decompression calculations Set the accurate personal statement If it is considered there are factors tend to increase the possibility of decompression illness making calculations more conservative by using this option is recommended Failure to set personal adjustment will cause erroneous dive and planning data This device used Li Polymer battery Li Polymer is a rechargeable battery that is thi...

Страница 7: ...ngs and that functions 3 1 FlowChart 3 1 1 Power ON OFF CYANO dive computer is shipped with power off so after open the box please turn on the power If the power doesn t turn on the device is not the defected but the battery is discharged so please turn it on after charge the battery refer charging method 3 2 1 ...

Страница 8: ...3 1 2 Function and button flow Ⅰ ...

Страница 9: ...3 1 3 Function and button flow Ⅱ ...

Страница 10: ...3 1 4 Function and button flow Ⅲ ...

Страница 11: ... maximum 10hours Clock mode at least 48hours Standby mode at least 15days 3 3 Setting from APP 3 3 1 Connecting bluetooth CYANO APP is available both on IOS Android Download from app Store Google Play When the bluetooth has been connected you can find Divelog and change the settings as pictures below After the first bluetooth connection set Protocol setting to make bluetooth connection popup to be...

Страница 12: ...rs 3 3 3 Setting up alarm 3 3 4 Setting up distance temperature unit When bluetooth is connected you can change alarm and distance temperature units settings at setting menu in the App 3 3 5 Setting up Current time and GPS You can change current time and GPS settings on Protocol setting at setting menu in the App ...

Страница 13: ...can check On time mode it can be changed with 1 to 4tier and on dive mode it is see it through number of icons on top left of display 3 3 7 Bluetooth on off adjust in the device You turn bluetooth On Off on setting menu and when it turned off battery would be saved However note that it is still on the list of bluetooth connection it will not work properly ...

Страница 14: ...auge mode and warning phrase and buzzer will not ring as well algorithm also won t be applied 3 3 9 Setting up Condition adjust in the device On the settings there are 3 set points Great Normal Pool and it can be changed by pressing top button According to what condition you have set level of conservatism changes too ...

Страница 15: ...zzer On Off adjust in the device You set Buzzer On Off and as the results all buzzers include alert in diving mode and others can be turned off It will help you to manage battery 3 3 12 Compss Calibration adjust in the device You can do the compass Clibration on COMPASS in the setting menu For more information about this please refer to 4 8 1 Compass Calibration ...

Страница 16: ...lgorithm of the way in which inert gases enter and leave the human body as the ambient pressure changes Various versions Bühlmann created with his successors are used to create Bühlmann decompression tables and to compute in personal dive computers no decompression limits and decompression schedules for dives in real time These decompression tables allow divers to plan the depth and duration for d...

Страница 17: ...wn ascent rate by 9m min after pass 18m of depth STEP3 For the best safety stay still in the depth of deep stop until the air is fully consumed After all Never dive again before you spend 24hours on land 4 3 limitations of Dive computer Even though current dive computer provides all the information of decompression divers must be aware that dive computer cannot catch the divers physical changes fo...

Страница 18: ...ving model when free dive Dive both scuba dive and free dive is not proved and may be exposed to possible unpredicted risks In any case of breath hold diving could cause Shallow Water Blackout SWB In general breath hold diving may nitrogen to be built up in blood and tissues Thus free diving after scuba diving within 2hours is prohibited and vice versa 4 6 Audible visual alarms The alarm system wi...

Страница 19: ...an be set up at EAN in setting menu before diving CYANO limits maximum depth for sport diving to within 40m Diving exceeding over 40m increases the exposure of Decompression illness and oxygen intoxication 4 8 pre checks List below should be checked out Is it suitable mode to dive Air Nitrox Gauge mode Is there enough remained battery Have compass Calibration done Is the unit correct m ft check on...

Страница 20: ...or long time battery warning can be appeared no matter the amount of battery remainder At the similar aspect if the dive computer is exposed to low temperature battery warning can be appeared too When battery is low as it showed in picture below battery should be started charging immediately 4 8 3 Diving at high altitude It is recommended not to travel high altitude area after diving at ground lev...

Страница 21: ...top is a good habitation for recreation divers Safety Stop prevents decompression illness microbubble formation and helps controlling ascending rate This device will activate mandatory safety stop for 3 mins after diving more than 10 mins 4 9 1 Mandatory Safety Stop When it reaches range of 8m depth the mode switches to Deep Stop mode and Up Down signal will appear Divers must stop until the Deep ...

Страница 22: ...g This chapter explains about how to activate dive computer and displayed signals meaning 5 1 Dive with the air mode Dive Air This Chapter shows imformation of Air mode Mode for diving can be changed in diving mode This device will automatically switch to diving mode when it reaches over 0 5m of depth ...

Страница 23: ...display as bar graph Bar graph will extend in length and colour will change as a warning if divers exceed the maximum speed allowance 9m min When divers ignore this warning and don t slow down nor stop SLOW signal will be appeared Do not exceed the maximum speed for ascend 9m min Danger of exceeding the maximum speed is to cause serious injuries or deadly situation ...

Страница 24: ...ression information Directed decompressing depth Ceiling Indicated depth where divers need to be reached for decompressing Do not ever ascend over directed decompressing depth Ceiling Doing so increase danger of decompression illness jighly Moverover Safety stop is very needed after decompression stop and ascend again when safety stop is over When safety stop is over mode switches to NDL This mean...

Страница 25: ...ge will cause oxygen intoxication Diving plan on dive computer also calculated based on oxygen ratio Basic nitrox setting CYANO RF is basically set oxygen percentage as 21 Divers can adjust oxygen percentage 2 1 to 99 6 3 Dive with Gauge mode Dive Gauge In the gauge mode Dive Time with minute and second is shown on left side of screen and current depth and time also Stopwatch will operate when you...

Страница 26: ...y or decompression diving it is needed to wait 12hours before boarding an airplane UHMS recommend divers to wait 24 hours if they dived decompression needed diving If divers dived more than 2 hours in 48hours it is recommended to wait 12hours If decompression needed diving was done it is better to wait 24hours at least 48hours if possible CYANO recommend divers to observe No Fly time that accordin...

Страница 27: ...ious settings of dive computer Time mode digital analog Colour of clock black blue white orange Alarms Temperature Celsius Fahrenheit Unit m ft orthography setting DIVE LOG DATA Diving profile Each diving duration Diving No Diving started time year month day time Oxygen percentage nitrox Water temperature Depth of water Log book function 7 6 No Dive mode If divers didn t practice as the dive compu...

Страница 28: ...erly please visit CYANO A S centre and ask for help CYANO RF should use proper protector When you problem with straps or buckles Please replace it from distributors Please clean with fresh water after each use Be careful with shock high temperature direct light and contacting with chemical substances Dive computer cannot stand shock from heavy materials like scuba tank or gasoline solvent spray gl...

Страница 29: ...onfirmation to divers after the waterproof test is done In case of a diver didn t get the confirmation or leakage caused because of inspection done by unauthorized places you cannot have compensation 9 Battery replacement Considering the waterproof problem battery replacement must be done in exclusive CYANO A S centre Leakage problem caused by users inappropriate battery replacement is out of CYAN...

Страница 30: ... display Resolution 0 1 C Accuracy 20 C 0 8 20 C 45 C 6 Clock Accuracy maximum 1 7s day at 20 C 68 F Display only in Nitrox mode Oxygen 21 99 Oxygen partial pressure display 1 4 bar Log Dive profile memory Memory capacity 50 100 times Sampling period 10s Operating conditions Working voltage for device over 3V Operating temperature 0 C 40 C Storage temperature 20 C 45 C It is recommended to be stor...

Страница 31: ...1 Copyright Trademark Patent KC registration of conformity Guarantee 11 1 Copyright This user manual is property of CYANO and no portion of this manual may be used distributed delivered disclosed copied nor reproduced without prior written consent 11 2 Trademark Trademarks such as CYANO WATOOM are protected by trademark laws 11 3 Patent This product is protected by the Korean Intellectual Property...

Страница 32: ...to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Part 15C This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received Including interference that may cause undesired operation FCC Caution Any changes...

Страница 33: ...is optional product you can buy separately While repairing or replacing the device some data and contents may possibly be lost therefore please make a backup file before having the device repaired or replaced CYANO or its official service centre do not have any responsibilities on losing contents and data by consumers negligence while repairing or replacing the device 12 Glossary NDL No Decompress...

Страница 34: ...not need to exercise compression stop while ascending OEA EAN EANx IT stands for Oxygen Enriched Air Nitrox O2 Oxygen Percentage of partial pressure of air in breathing gas The standard air contains 21 oxygen Repetitive dive Diving while in limit time of decompression which affected by leftover nitrogen from previous diving Residual nitrogen Amount of left over nitrogen saturation in divers body a...