4.8.4 Personal settings
Set points are divided by 3 as shown chart below depend on personal physical condition and diving experience.
Mathematical calculation of the dive computer will depend on the set points, and decompression diving time will be shortened when it set as POOL.
▫
NORMAL
- Basic set point.
▫
POOL
- Set point for when it is somewhat dangerous or it has possible danger of decompression illness.
▫
GREAT
- Set point for when both atmosphere and your condition are best.
4.8.5 Outbreaking conditions of decompression illness
Conditions list below differ person by person
▫
Diving at below 20degree
▫
When physical condition is weakened than ordinary people
▫
When fatigue
▫
When dehydrated
▫
When experienced decompression illness
▫
When stressed
▫
Obesity
▫
When suffering from Patent Foramen Ovale (PFO)
▫
When exercise strenuously before and after diving
4.9 Safety Stop (S-STOP)
Safety Stop is a good habitation for recreation divers. Safety Stop prevents decompression illness, microbubble formation, and helps controlling ascending rate
This device will activate mandatory safety stop for 3 mins after diving more than 10 mins.
4.9.1 Mandatory Safety Stop
When it reaches range of 8m depth, the mode switches to
Deep Stop mode, and Up/Down signal will appear.
Divers must stop until the Deep Stop mode disappear.
When Deep Stop mode is activated, divers should not ascend
over 5m depth. If divers ascend over directed depth, downward
arrow(picture 1. shown on the right side) will appear and constant
alarm will ring. On the same extend, if divers didn't reach the
directed depth, upward arrow(picture 2. show on the right side) will
appear and constant alarm will ring. Divers should ascend or descent to the range of depth for Deep Stop. When it is followed properly, decompression affection
comes while re-diving will be vanished. However, when it is violated, next diving may be prohibited based of calculation by algorithm. It is recommended to have
enough surface interval