background image

Installation and Operation 

-

 

Upon removing the pump from carton, 
inspect for possible damaged or missing 
components from transit from CVS 
Controls. Contact a CVS controls 
representative should there be any 
concerns. 
 

-

 

Blow out and remove potential debris 
from supply line before hooking up 
supply air/gas to inlet.  Supply pressure 
should be regulated with a maximum 
setting of 50 psi. 
 

-

 

Connect suction line to pump head. 
 

-

 

A line check should be installed in the 
discharge line close to the point of 
injection. (note the direction of the flow 
arrow) CVS Controls offers the          
CVS-B-0283 line check in stainless steel, 
for all plunger sizes which will 
withstand a working pressure of 6000 
psi. 
 

-

 

Connect the discharge line to the ¼” 
FNPT in both the line check and the Top 
Bushing (CVS-A-0152) of the head 
assembly. Ensure the line is clear of all 
debris. 
 

-

 

Partially open Bleeder Valve              
(CVS-A-0123) 
 

-

 

Connect the gas supply line, considering 
the pressure required of the pump. If 
the gas exceeds 50 psi, the supply 
should be equipped with a regulator to 
reduce the pressure to 50 psi. 

Lubrication 

A stick lubricator (CVS-A-3179) is inserted into 
the grease assembly (CVS-A-0558) upon 
manufacturing. CVS controls has available and 
recommends CVS-A-3179 for most fluids. No 
lubrication stick is required if the pump is 
equipped with Teflon packing and chrome 
plated plunger. 

 

Operation 

1.

 

Remove the body cover (CVS-B-0004) 
and cover gasket (CVS-B-0036) 
 

2.

 

Open the main air/gas supply valve and 
slowly open the exhaust valve          
(CVS-A-2489). The pump should 
automatically start. Ensure the suction 
line is primed with fluid, and then test 
the pump head by opening the Bleeder 
Valve (CVS-A-0123). The fluid escaping 
from the bleeder valve may contain 
bubbles. As soon as the bubbles 
subside, close the bleeder valve for 
normal operation. 
 

3.

 

Adjust for desired volume by 
considering pump speed using the flow 
control. Consider the position of Brass 
Adjusting Pin (CVS-A-0035)to adjust 
stroke.                                                    

 

 

 

 

Содержание 50-1-DMV

Страница 1: ...ts a high volume pneumatic valve Operating mechanism is gasket sealed to protect from the environmental elements Safety valve provides for protection on case of accidental overpressure of the main dia...

Страница 2: ...0123 Connect the gas supply line considering the pressure required of the pump If the gas exceeds 50 psi the supply should be equipped with a regulator to reduce the pressure to 50 psi Lubrication A...

Страница 3: ...er tightened This may score the plunger and decrease the lifespan of the packing CVS chemical pumps used for alcohol or methanol injection must be fitted with Buna N o rings Pumps used for most chemic...

Страница 4: ...d If the pump is running but not pumping the injection head could be air locked Open the priming valve and bleed fluid until no bubbles are present If still not pumping the bottom seat of the injectio...

Страница 5: ...7 740 748 756 779 802 854 872 897 937 984 1017 1057 1090 1122 1 4 LongStroke 280 281 282 284 285 286 289 292 295 297 300 303 306 318 330 356 368 380 404 428 454 476 500 522 3 8 ShortStroke 355 356 356...

Страница 6: ...CVS Series 50 Chemical Injection Pump Assembly 6...

Страница 7: ...A 2489 Exhaust Valve 1 22 CVS A 2970 Wing Screw 1 23 CVS A 4452 3 8 Hex Bolt 4 24 CVS B 0002 Series 50 Diaphragm Disc 1 25 CVS B 0003 Series 50 Thrust Rod 1 26 CVS B 0004 Series 50 Cover Body 1 27 CVS...

Страница 8: ...acking Nut 1 1 4 1 7 CVS A 0404 Series 50 1 1 4 Plunger Packing Gland 1 8 CVS A 0405 Packing 1 9 CVS A 0406 Series 50 1 1 4 Adapter 1 10 CVS A 0408 Series 50 1 1 4 Plunger 1 11 CVS A 0521 Gasket 1 12...