background image

 

Assembly continued, 

 

9.  Ensure that the warning nameplate (Key 27) is in 

place and install the diaphragm (Key 25) and the 

upper diaphragm casing (Key 26). 

10. Install the cap screws and hex nuts (Keys 45 and 

44).  Tighten cap screws evenly using a 

crisscross pattern to compress the spring, and 

then secure the upper diaphragm casing. 

11. Refer to the appropriate valve body instruction 

manual for lever/valve shaft orientation marks, 

and slide the lever (Key 33) into place.  See 

Figure 5 for correct lever operating clearance.  

Clamp with the cap screw (Key 10). 

12. Rotate the lever (Key 33) until it aligns with the 

rod end bearing (Key 13).  This connection can 

be assisted by stroking the actuator off its up 

travel stop using a regulated air source. 

13. Apply a thread-locking compound to the threads 

of the cap screw (Key 12). 

14. Connect the lever (Key 33) and the rod end 

bearing (Key 13) with the cap screw and hex 

nuts (Keys 12 and 31). Tighten the cap screw to 

the torque as recommended in Table 3). 

15. If a valve positioner is being used with the 

assembly, consult the appropriate manual for 

positioner installation. 

16. Coat the bearing surfaces of the hub (Key 30) 

and the cover (Key 41) with a suitable lubricant.  

Install the bushing (Key 40) and hub into the 

cover and secure with the retaining ring (Key 

36). 

17. Install the travel indicator scale (Key 39) and 

secure with self-tapping screws (Key 37). 

18. Make note of the valve position and direction of 

rotation and position the travel indicator (Key 38) 

accordingly. 

19. Replace the cover (Key 41) and secure with cap 

screws and washers (Keys 8 and 9).  If the holes 

in the cover and housing (Key 17) do not align, 

use a regulated air source to move the actuator 

slightly off its up travel stop.  If this does not 

result in proper alignment, temporarily loosen the 

cap screws (Key 32) and shift the housing 

slightly.  Do not stroke the actuator while the 

cover is off. 

20. Refer to the Adjustment section of this manual 

for correct actuator turnbuckle adjustment. 

Changing Actuator Mounting 

Generally the actuator is positioned vertically in a 

horizontal pipeline, however there are four possible 

mounting styles and for possible positions for each 

style.  Refer to Figures 3 and 4. 

*The size 70 Series 1052 

must be externally supported if mounted horizontally due to the 

weight. 

 

Correct lever/valve shaft positioning is important in 

ensuring proper valve action.  Refer to the 

appropriate valve body instruction manual. 

 

Warning:  The sudden release of process 

fluid can cause personal injury or property 

damage.  Prior to starting adjustment 

procedures: 

 

Isolate the valve from the process, 

 

Release the process pressure, and 

 

Vent the actuator loading pressure. 

 

Style A is right-hand mounted and Style D is left-

hand mounted.  In all other ways Styles A and D are 

identical. 

 

Style B is right-hand mounted, while Style C is left-

hand mounted.  In all other ways Styles B and C are 

identical. 

 

Refer to the following procedure to convert from 

Styles A and D to Styles B and C or vice versa, or to 

change the mounting position.  Key numbers refer to 

Figures 7 & 8. 

 

1.  Remove the cover (Key 41) by unscrewing and 

removing the cap screws and washers (Keys 8 

and 9). 

2.  Unscrew cap screw (Key 12) and loosen cap 

screw (Key 10). 

 

Warning:  Do not use a hammer to drive the lever 

off the drive shaft.  This could cause damage to 

internal valve parts.  On some valves, driving the 

lever could move the valve ball and bearings away 

from the centered position, resulting in damage to 

valve parts as the valve is operated. 

 

If using a tool to remove the lever is necessary, 

use a wheel puller.  Tapping the wheel puller 

screw lightly to loosen the lever is permissible, 

but excessive force could also result in damage to 

valve parts and disruption of the centered position 

of the valve disk and bearings. 

 

3.  If changing styles,  

a.  Remove the cap screws (Key 32) and the 

actuator housing (Key 17) from the mounting 

yoke (Key 35). 

b.  Rotate the housing 180 degrees while 

maintaining the appropriate position (1, 2, 3 

or 4) and place the actuator onto the 

mounting yoke (Key 35). 

4.  If changing positions, remove cap screws (Key 

32) and rotate the actuator housing to the 

desired position. 

 

 

 

Содержание 1051 Series

Страница 1: ...ositioner The stroking time is dependent on the actuator size rotation spring rate initial spring compression and supply pressure If the stroking time is critical for your application consult CVS Cont...

Страница 2: ...degrees with optional fixed stops Acceptable Valve Shaft Diameters In mm Size 30 1 2 12 7 mm 5 8 15 9 mm 3 4 19 1 mm Size 40 1 2 12 7 mm 5 8 15 9 mm 3 4 19 1 mm 7 8 22 2 mm 1 25 4 mm 1 1 4 31 8 mm Si...

Страница 3: ...ews Key 32 and shift the housing slightly Do not stroke the actuator while the cover has been removed 15 Refer to the instructions in the Adjustment section of this manual and properly adjust the actu...

Страница 4: ...hould a volume booster or valve positioner be used ensure that it is properly connected to the factory If a valve positioner is part of the assembly the connection will likely be made at the CVS Contr...

Страница 5: ...the actuator housing and blocking the stroke path Add pressure to the diaphragm casing to stroke the actuator down and provide access to the left hand threaded upper locknut Key 18 Loosen the locknut...

Страница 6: ...ntrol valve assembly includes a valve positioner remove it from the assembly 3 Remove the cap screws and washers Keys 8 and 9 as well as the cover Key 41 4 Remove the retaining ring and then the hub K...

Страница 7: ...r Key Numbers 1 If the bushing Key 34 was replaced press in the new bushing and ensure the end of the bushing is flush with the bottom of the recess in the mounting yoke Key 35 2 Slide the mounting yo...

Страница 8: ...stment Changing Actuator Mounting Generally the actuator is positioned vertically in a horizontal pipeline however there are four possible mounting styles and for possible positions for each style Ref...

Страница 9: ...regulated air source Note Tighten cap screw Key 12 to the recommended bolt torque shown in Table 3 10 Position the travel indicator Key 38 according to the valve position and direction of rotation 11...

Страница 10: ...le zn pl steel Size 30 CVS12A9623X012 Size 40 CVS22A9625X012 6 Cover Plate steel Not required with positioner CVS22A9359X012 Size 60 CVS22A9624X012 17 Housing aluminum Size 30 CVS46A0463X022 7 Cap Scr...

Страница 11: ...12 req d CSV1A675124052 Size 40 16 req d 28 Seal steel synthetic rubber Size 30 40 CVS12A9451X012 Size 60 24 req d 46 Travel Indicator SST not shown CVS12A9693X012 Size 60 CVS12A9452X012 47 Machine Sc...

Страница 12: ...ly as a replacement part Key 30 Hub Aluminum or 416 sst Actuator Size Valve Shaft Diameter Key 30 Hub In mm 30 1 2 12 7 CVS22A9496X012 40 3 4 19 1 CVS22A9497X012 7 8 22 2 CVS22A9486X012 60 1 25 4 CVS2...

Страница 13: ...CVS Series 1052 Size 40 Assembly 13...

Страница 14: ...Series 1052 Size 40 Assembly Parts List 14...

Страница 15: ...Series 1052 Size 60 Assembly 15...

Страница 16: ...CVS Series 1052 Size 60 Assembly Parts List 16...

Страница 17: ...CVS Series 1052 Size 70 Assembly 17...

Страница 18: ...CVS Series 1052 Size 70 Assembly Parts List 18...

Страница 19: ...CVS Series 1051 1052 Dimensional Data inches 19...

Страница 20: ...information included in this publication is presented for informational purposes only CVS Controls Ltd reserves the right to modify or change and improve design process and specifications without wri...

Отзывы: