CUTRA WC40000F25W Скачать руководство пользователя страница 5

03

Methods of use

01

Press the power button of the main body for 1 to 2 seconds to turn the LED
on the face panel on. This turns the product into stand-by state.
(another push will turn the power button off.)

* The LED(green) on the handle is off.

02

Pull the handle out inside the main body.

03

At stand-by state, press the power button on the handle. This will cause
40,000 vibrations per second. The cutter only operates while being pressed.

* The LED(green) on the handle is on.

04

When used for more than 10 minutes, the product stops operating and goes into
stand-by state.

* The LED(green) on the handle is off under stand-by state. The inner temperature of the
   handle gets higher while being used, turning into high temperature stationary state.
* The LED button of the handle does not turn on in high temperature stationary state.
* The stand-by state extends based on the handle power button.
* When the main body is on, the vibrating part continually creates sound waves so
   the product must be turned off when not in use. In order to prevent putting the
   handle into the main body unconsciously, the product is designed to beep.

Содержание WC40000F25W

Страница 1: ...INSTRUCTION MANUAL...

Страница 2: ...Accessories 01 01 10 10 11 04 02 05 05 06 07 08 Replacem ent of blade and replacem ent of blade fixture About blade and blade fixture W arnings and cautions Custom er service Com pensation for dam age...

Страница 3: ...r button Cable Belt clip Leg Remaining battery LED Handle Cutter Power switch Blade 40p Transducer horn Vibrator Charger Handle Cutter Accessories Check for the following components The battery pack i...

Страница 4: ...01 02 03 04 Methods of use How to use the product 02 C U C U U...

Страница 5: ...e handle is on 04 When used for more than 10 minutes the product stops operating and goes into stand by state The LED green on the handle is off under stand by state The inner temperature of the handl...

Страница 6: ...tes high temperature vibration and protective function is activated as the circuit is overload The power button on the switch cannot be operated The LED green button does not turn on Loose setscrew of...

Страница 7: ...and Precautions Precautions Ultrasonic wave cutter cuts better than the normal cutter so be careful Wear necessary equipment such as safety glasses Wear safety gloves before using the product at all c...

Страница 8: ...e product turns off When the product turns off tighten the setscrew until there are 3 to 4 LED lights on 4 Once the setscrew is fixed turn the power of the main body on and press the handle switch on...

Страница 9: ...areful with the dead end of blade and the direction of blade Use the designated blades only When other than designated blades are used the product might not operate correctly and this can cause breakd...

Страница 10: ...electric current on Grab the plug in order to pull out the charger Keep the product away from children Do not give strong physical impact on the product Do not remodel or decompose the product Never r...

Страница 11: ...caused Turn the power off when changing blades or working on maintenance Do not use the device on anything else than what it is meant for Fix the blade correctly before using Use the designated blade...

Страница 12: ...d or which are warned against in the user manual Do not use the device if the cable is damaged or has visible cracks If the cable is damaged you must have it replaced by Cutra Co Ltd or a service cent...

Страница 13: ...de fixture setscrew and the dead end of the vibrator The product is a light ultrasonic wave cutter Do not exert too much power and hold it correctly If the blade is not correctly fixed the vibration t...

Страница 14: ...ls do you want to cut Crowdfunding results PLASTIC FELT KRAFTPLEX LEATHER PAPERBOARD ACRYLIC RUBBER BALSA FORMEX Funding Goal 50 000 Total Funding Raised 173 229 Total Backers 602 Reached Funding Goal...

Страница 15: ...atents Featured On Certificate of Patent A patent application for its technology Gold Prize Seoul International Invention Fair 2016 Gold Prize 44th Salon International Des Inventions Geneve Certificat...

Страница 16: ...LTD Address Inha UNIV DreamCenter1 no 310 Inha ro 100 Nam gu Incheon Republic of Korea 22212 FAX 82 0504 475 0927 Website wondercutter com Email wondercutter naver com Skype Linkedin cutra official g...