background image

Pub 49004

Page 8

Ratings

HP and KW Ratings

Standard Duty Ratings
25-Second Ramp, 4 Starts per Hour, 300% Current Limit @ 40

o

C

15-Second Ramp, 4 Starts per Hour, 300% Current Limit  @ 50

o

C

50-Second Ramp, 2 Starts per Hour, 300% Current Limit @ 50

o

C

Effective 9/00

Frame

Max

Catalog

Width

Current

Number

230 380-400

440

Volt

Volt

Volt

1.0SF

1.15SF 1.0SF

1.15SF 1.0SF

1.15SF

1.0SF

1.15SF

65mm

34

9

15

18.5

10

7.5

10

10          25

20

30

25

S801N37N3S

63

15          30

33           20

15           20

20          40

40

60

50

N66N3S

110 mm

96

25          45

55           30

25           30

30          75

60

75

75

S801R10N3S

120           33

63           63

40

30           40

40          75

75           100

100

R13N3S

Three-Phase Motor

kW Rating (50 Hertz)

hp Rating (60 Hertz)

200V

230V

460V

575V

Frame

Max

Catalog

Width

Current

Number

230

380-400

440

Volt

Volt

Volt

1.0SF

1.15SF

1.0SF

1.15SF

1.0SF

1.15SF

1.0SF

1.15SF

65mm

34

9

15

18.5

10

7.5

10

10

25

20

30

25

S801N37N3S

63

15

30

33

20

15

20

20

40

40

60

50

N66N3S

110 mm

96

25

45

55

30

25

30

30

75

60

75

75

S801R10N3S

120            33

63

63

40

30

40

40

75

75

100            100

R13N3S

Three-Phase Motor

kW Rating (50 Hertz)

hp Rating (60 Hertz)

200V

230V

460V

575V

Frame

Max

Catalog

Width

Current

Number

230

380-400

440

Volt

Volt

Volt

1.0SF

1.15SF

1.0SF

1.15SF

1.0SF

1.15SF

1.0SF

1.15SF

65mm

21

5.5

10

11

5

5

5

5

15

10

15

15

S801N37N3S

42

11

18.5

22

10

10

15

10

30

25

40

30

N66N3S

110 mm

60

15

30

33

15

15

20

15

40

40

50

50

S801R10N3S

80

22

40

45

25

20

30

25

60

50

75

60

R13N3S

Three-Phase Motor

kW Rating (50 Hertz)

hp Rating (60 Hertz)

200V

230V

460V

575V

15-Second Ramp, 4 Starts per Hour, 450% Current Limit @ 40

o

C

Frame

Max

Catalog

Width

Current

Number

230

380-400

440

Volt

Volt

Volt

1.0SF

1.15SF

1.0SF

1.15SF

1.0SF

1.15SF

1.0SF

1.15SF

65mm

29

7.5

12.5

15

7.5

7.5

10

7.5

20

15

25

20

S801N37N3S

49

12.5

22

25

15

10

15

15

30

30

40

40

N66N3S

110 mm

73

18.5

37

40

20

20

25

20

50

40

60

60

S801R10N3S

94

25

45

55

30

25

30

30

60

60

75

75

R13N3S

Three-Phase Motor

kW Rating (50 Hertz)

hp Rating (60 Hertz)

200V

230V

460V

575V

Frame

Max

Catalog

Width

Current

Number

230

380-400

440

Volt

Volt

Volt

1.0SF

1.15SF

1.0SF

1.15SF

1.0SF

1.15SF

1.0SF

1.15SF

65mm

29

7.5

12.5

15

7.5

7.5

10

7.5

20

15

25

20

S801N37N3S

49

12.5

22

25

15

10

15

15

30

30

40

40

N66N3S

110 mm

73

18.5

37

40

20

20

25

20

50

40

60

60

S801R10N3S

94

25

45

55

30

25

30

30

60

60

75

75

R13N3S

Three-Phase Motor

kW Rating (50 Hertz)

hp Rating (60 Hertz)

200V

230V

460V

575V

30-Second Ramp, 4 Starts per Hour, 450% Current Limit @ 40

o

C

Frame

Max

Catalog

Width

Current

Number

230

380-400

440

Volt

Volt

Volt

1.0SF

1.15SF

1.0SF

1.15SF

1.0SF

1.15SF

1.0SF

1.15SF

65mm

21

5.5

10

12.5

5

5

5

5

15

10

15

15

S801N37N3S

40

11

18.5

22

10

10

10

10

30

25

30

30

N66N3S

110 mm

55

15

25

30

15

15

20

15

40

30

50

40

S801R10N3S

75

22

37

45

20

20

25

20

50

50

60

60

R13N3S

Three-Phase Motor

kW Rating (50 Hertz)

hp Rating (60 Hertz)

200V

230V

460V

575V

Содержание S801N

Страница 1: ...stors connected in a full wave power bridge The voltage and current applied to the motor is controlled by varying the thyristor conduction period This in turn controls the torque supplied by the motor...

Страница 2: ...Required S801N 10 32 x 0 5 Standard 10 4 1 7 N m 65mm Lockwasher and 15 in lb 2 55 in Flat Washer S801R 1 4 20 x 0 625 Standard 1 4 4 2 8 N m 110mm Lockwasher and 25 in lb 4 33 in Flatwasher Required...

Страница 3: ...es per mounting hole location as shown To mount the unit use all the hardware specified in Table 1 on page 2 of this leaflet Tighten to the torque specified TO AVOID SHOCK HAZ ARD DISCONNECT ALL POWER...

Страница 4: ...UNE TENSION DE 24V C C AUX BORNES SAUF AVIS CONTRAIRE DANS CE MANUEL TOUTE LA FILERIE DE COMMANDE EST DE CALIBRE 22 A 12 AWG L INOBSERVATION DE CETTE MESURE POURRAIT CAUSER DES DOMMAGES IMPORTANTS AU...

Страница 5: ...OULD RE SULT IN SEVERE DAMAGE TO THE CONTROLLER CAUTION APPLIQUER UNE TENSION DE 24V C C AUX BORNES SAUF AVIS CONTRAIRE DANS CE MANUEL TOUTE LA FILERIE DE COMMANDE EST DE CALIBRE 22 A 12 AWG L INOBSER...

Страница 6: ...ce the unit is energized it will communicate with the CIM and load the program into the Soft Starter Allow the unit 2 seconds to ensure communication checks complete and values are set To verify CIM i...

Страница 7: ...stantaneous overcurrent 41 24V power supply low 42 Timer system fault 43 Watchdog reset occurred 44 PLL DSP 45 Illegal address DSP Effective 9 00 Table 7 Fig 6 Soft Start Control Interface Module CIM...

Страница 8: ...15 30 33 15 15 20 15 40 40 50 50 S801R10N3S 80 22 40 45 25 20 30 25 60 50 75 60 R13N3S Three Phase Motor kW Rating 50 Hertz hp Rating 60 Hertz 200V 230V 460V 575V 15 Second Ramp 4 Starts per Hour 450...

Страница 9: ...42 11 18 5 22 10 10 15 10 30 25 40 30 N66N3S 110 mm 65 15 30 33 15 15 20 15 50 40 50 50 S801R10N3S 80 22 40 45 25 20 30 25 60 50 75 60 R13N3S Three Phase Motor hp Rating 60 Hertz kW Rating 50 Hertz 20...

Страница 10: ...800 356 1243 For service or start up assistance 24 hours day 7 days week please call 1 800 498 2678 Cutler Hammer Solid State Reduced Voltage Motor Starter Aftermarket Services Technical telephone su...

Отзывы: