2.4 INTERFACES OF PLUSII-C-0004
The printer with a parallel Centronics interface, 0004 option, has a molex 15-pin male connector 53261 series
(90°). Refer to the table below for the connector pin signals:
Centronics
1
15
Model no. type
Header :
Molex 53261 series 15 pin
Housing :
Molex 51021 series 15 pin
(no.
51021-1500)
PIN
SIGNAL
IN /OUT
DESCRIPTION
1
AD0
IN
Data 0
2
AD1
IN
Data 1
3
AD2
IN
Data 2
4
AD3
IN
Data 3
5
AD4
IN
Data 4
6
AD5
IN
Data 5
7
AD6
IN
Data 6
8
AD7
IN
Data 7
9
BUSY
OUT
Peripheral not ready to receive data
10
ERROR
OUT
Error
11
PAPER END
OUT
Paper end
12
ACK
OUT
Acknowledge
Setting
FEED
(1)
IN
FEED signal (active at low level)
with JP5
(2)
13
STROBE
IN
Strobe
14
GND
Ground signal
Setting
LED
OUT
LED signal (external)
with JP6
(2)
15
GND
Ground signal
(Tab.2.4)
(Fig.2.8)
2. INTERFACES
User Manual
PLUS II 2-9
Содержание PLUS II
Страница 1: ...OEM USER MANUAL PLUS II PLUS II Command Reference DOMC 0009e ...
Страница 5: ...1 4 5 PLUS II USB NOTE 1 RESERVED interface only for service use Fig 7 User Manual PLUS II ...
Страница 14: ...Blank page INTRODUCTION 6 PLUS II User Manual ...
Страница 29: ...2 3 4 Fig 1 20 Fig 1 19 Fig 1 18 1 INSTALLATION AND USE User Manual PLUS II 1 15 ...
Страница 32: ...Blank page 1 INSTALLATION AND USE 1 18 PLUS II User Manual ...
Страница 50: ...Blank page 3 TECHNICAL SPECIFICATIONS 3 6 PLUS II User Manual ...
Страница 63: ......