8
4.
CLEAN WATER REGENERATION WITH AUTOFLUSH
For installations with a high fouling potential, a back flush surge tank and/or a Separate Source Regeneration Valve (SEPS) or
three way valve on the inlet is recommended . During regeneration the three way valve will close the normal service inlet and
open the inlet from the back flush surge tank . The back flush surge tank supplies clean, treated water for regeneration . A 50
gallon (total volume) Pressure Tank is advisable . This is the minimum needed tank size to perform a treated water backwash .
For systems with AutoFlush, follow the instructions accompanying the NHBP . Make sure the drain receptacle can adequately
handle the flow from this line .
CLEAN WATER REGENERATION AND AUTOFLUSH
RAW WATER
INLET
NO HARD
WATER BYPASS
(#CV3070FM)
EXPANSION
TANK
FRESH
WATER TANK
5
MICRON
FILTER
CHECK
FRESH
WATER TANK
EXPANSION
TANK
TREATED
WATER
OUTLET
TREATED
WATER
OUTLET
No Hard Water Bypass
(#CV3070FM)
*Wires reversed for AutoFlush
RAW WATER
INLET
NO HARD
WATER BYPASS
NO HARD
WATER BYPASS
(AutoFlush)
(#CV3070FM)
EXPANSION
TANK
FRESH
WATER TANK
TREATED
WATER
OUTLET
Overhead View
CAUTION:
This backflush surge tank must be sized to provide enough water for the entire regeneration
whether an auto flush kit is installed or the chlorine generator option is used.
NOTE:
When a NHWB is used in an AutoFlush installation, it is necessary to reverse the wires
connected to the board. See the "Configuring Wires for AutoFlush Connection" section for
instructions to confirm or change the wire orientation.
*See additional programming settings section on pages 29-30 of this manual for more information regarding this installation.
The following parts are required for the listed
installations but are not included with the unit.
• Lower tank shut-off valve
• Spring Assisted check valve (see drawing
for location)
• No Raw Water Bypass x2 (CV-3070FM)
– For Clean Water Regen
– For AutoFlush (wires reversed)