3
PRE-INSTALLATION INSTRUCTIONS FOR DEALERS
The manufacturer has preset the water treatment units sequence of cycles, cycle times, salt dosage and salt refill time, if
used . The installing dealer should read this guide thoroughly before set up, installation, and operation of equipment . If
there are any question regarding the operation of UF-835 please consult the manufacturer .
The dealer
should read this page and guide the installer regarding regeneration, service alarm, and programming
settings prior to installation.
For the installer
, the following must be used:
• Set the following Installer Settings
– Gallon Setting
– Every Day Regeneration
– Service Alarms and Alarm Times (if desired)
• Read Normal Operating Displays
– Set Time of Day
• Read Installation Instructions
– Allow Space for Membrane Removal
– Installation must be in compliance with all state and local regulations
For the homeowner
, please read Programming Procedures and Operating Displays and Maintenance sections .
During operation, the normal user display is
time of day
and
gallons per minute
.
Flow Rate, Vacation Mode, Capacity
Remaining and Days to a Regeneration
are optional displays but are not normally used . (Vacation Mode is used only
when there will be no water usage for an extended period of time . Once 50 gallons of water is used, the unit will
automatically regenerate that night and resume normal operation .) Each of these can be viewed by pressing
NEXT
to
scroll through them . When stepping through any programming, if no buttons are pressed within 5 minutes, the display
returns to a normal user display . Any changes made prior to the 5 minute time out are incorporated . To quickly exit any
Programming, Installer Settings, etc ., press
SET
CLOCK
. Any changes made prior to the exit are incorporated .
Ultra Filtration Flushing Schedule
The UF Series Filter is factory preset to backwash every day at midnight . This is dependent on the quality of water being
treated and may be adjusted by the installing dealer based on the water quality . A post ultra-filtration pressure tank may
be installed to ensure a sufficient flow of water and pressure to the home during a flush cycle .
IMPORTANT:
If a post pressure tank is used a check valve may be required to allow for treated water regeneration . In
this case an expansion tank should be installed to account for thermal expansion . See drawing in the back of this manual .
Default Factory Setting
Standard Unit with or without Separate Source Regeneration (SSR)
Flush Frequency: Every Day
Backwash Flush Duration: 2 Min . at 5 .3 GPM
Rinse Duration: 1 Min . @ 5 .3 GPM