background image

All rights reserved. Total or partial reproduction of this manual in whatever form, whether by printed or elec-
tronic means, is forbidden. While guaranteeing that the information contained in it has been carefully checked, 
CUSTOM ENGINEERING SPA and other entities utilized in the realization of this manual bear no responsibility 
for how the manual is used.
Information regarding any errors found in it or suggestions on how it could be improved are appreciated. Since 
products are subject to continuous check and improvement, CUSTOM ENGINEERING SPA reserves the right 
to make changes in information contained in this manual without prior notifi cation.

Copyright © 2007 CUSTOM ENGINEERING S.p.a. – Italy

CUSTOM ENGINEERING S.p.A.
Str. Berettine 2 - 43010 Fontevivo (PARMA) - Italy
Tel.: +39 0521-680111  - 

Fax: +39 0521-610701

http: www.custom.it

Customer Service Department:
Tel.: +39 059 88 69 587
Email: [email protected]

Содержание Plus II

Страница 1: ...OEM USER MANUAL PLUS II PLUS II ...

Страница 2: ... is used Information regarding any errors found in it or suggestions on how it could be improved are appreciated Since products are subject to continuous check and improvement CUSTOM ENGINEERING SPA reserves the right to make changes in information contained in this manual without prior notification Copyright 2007 CUSTOM ENGINEERING S p a Italy CUSTOM ENGINEERING S p A Str Berettine 2 43010 Fontev...

Страница 3: ...INTER COMPONENTS A PLUS II Front view 1 Paper mouth 2 STATUS Led 3 OPEN key for paper roll compartment opening 4 FEED key 5 Paper roll compartment 6 Paper end sensor Fig 1 1 5 2 3 4 6 User Manual PLUS II ...

Страница 4: ...Power supply connector 8 RS232 TTL Serial interface connector 9 CENTRONICS TTL Parallel interface connector PLUSII S PLUSII T PLUSII S 0004 X 9 X 7 PLUSII C 0004 PLUSII C PLUSII P X 8 X 7 X 9 X 7 X 8 X 7 PLUS II User Manual ...

Страница 5: ... 6 1 4 1 Power supply 1 6 1 4 2 Setting parallel interface 1 7 1 5 CONNECTIONS OF PLUSII C 0004 1 8 1 5 1 Power supply 1 8 1 5 2 Setting parallel interface 1 9 1 5 3 Setting JP5 and JP6 jumpers 1 9 1 6 SELF TEST 1 10 1 7 CONFIGURATION 1 11 1 8 HEXADECIMAL DUMP 1 11 1 9 MAINTENANCE 1 12 1 9 1 Changing the paper roll 1 12 1 9 2 Notes about the installation 1 13 1 9 3 EASYLOCK fixing system 1 14 2 IN...

Страница 6: ...X A ACCESSORIES AND SPARE PARTS A 1 ACCESSORIES A 1 A 1 1 Power supply A 1 A 1 2 Adaptor frame kit 112X112 A 2 A 1 3 Data and power supply cables kit for PLUSII S and PLUSII T A 5 A 1 4 Data serial cable kit for PLUSII S 0004 A 6 A 1 5 Data and power supply cables kit for PLUSII C and PLUSII P A 7 A 1 6 Data serial cable kit for PLUSII C 0004 A 8 A 2 SPARE PARTS A 9 A 2 1 Supplies A 9 TABLE OF CON...

Страница 7: ...ar water Do not use the printer on unstable surfaces that might cause it to fall and be seriously damaged During the integration of the printer we strongly warn to keep an adeguate paper loop outlet underneath the presenter in order to allow the receipt being properly printed out Only use the printer on hard surfaces and in environments that guarantee proper ventilation Make sure the printer is pl...

Страница 8: ...are present and that there are no signs of damage If there are contact Customer Service 1 Box 2 Fixing hooks 3 Paper roll inside the printer 4 Printer Open the printer packaging Take out the fixing hooks and remove it from its plastic covering Take out the printer and remove it from its plastic covering Keep the box packing materials in the event the printer must be transported shipped in the futu...

Страница 9: ...ble hook lock system makes PLUS II safe and reliable PRINTER DESCRIPTION The printer see Fig 1 has an ABS casing with a front cover 5 which opens to allow access to the paper roll and print head The control panel is located on the front and has a FEED key 4 and an OPEN key 3 for paper roll compartment opening The OPEN key is made of transparent plastic material so it works also as a STATUS Led 2 F...

Страница 10: ...Blank page INTRODUCTION 4 PLUS II User Manual ...

Страница 11: ...better use with the printer the self adhesive area must comply with the following dimensions see Fig 1 1 57 0 5 SELF ADHESIVE HEAT SENSITIVE SIDE 42 10 5 LINERLESS PAPER SPECIFICATIONS Self adhesive Water based acrylic Self adhesive mass Permanent 16 gr m2 2gr Total thickness 93 μm 2 μm Total weight 96 gr m2 2gr Recommended temperature Stick from 15 C to 40 C Storage from 10 C to 40 C Resistance a...

Страница 12: ...nnector pins are as follows Model no type Header S4B PH K S 90 JST Housing PHR 4 JST or equivalent PIN SIGNAL DESCRIPTION 1 GND Ground signal 2 GND Ground signal 3 Vin Head voltage 4 Vcc Logic supply voltage NOTE For the electrical specifications see Chapter 4 WARNING Respect the polarity of the power supply Fig 1 2 1 INSTALLATION AND USE 1 2 PLUS II User Manual ...

Страница 13: ... 3 manages the setting of serial interface as indicated SERIAL JP4 JP5 JP6 JP7 RS232 TTL Refer to Fig 1 3 for the jumpers position JP5 JP6 JP7 JP4 RS232 TTL JUMPERS SELECTION INTERFACE JP5 JP6 JP7 JP4 RS232 TTL JUMPERS SELECTION INTERFACE Fig 1 3 1 INSTALLATION AND USE User Manual PLUS II 1 3 ...

Страница 14: ...gnals on the connector pins are as follows Model no type Header 90 Terminal block pitch 5 08mm Housing Terminal block AWG 20 14 PIN SIGNAL DESCRIPTION 1 GND Ground signal 2 Vin Logic supply voltage NOTE For the electrical specifications see Chapter 4 WARNING Respect the polarity of the power supply Fig 1 4 1 INSTALLATION AND USE 1 4 PLUS II User Manual ...

Страница 15: ...has not effects If JP8 is open When the printer is powered up the low consumption mode is activated An impulse of at least 500 m sec on pin 6 of the serial RS232 connector must be given to switch on the printer see par 2 2 1 and table 2 2 Use ESC 0 command to switch off the printer and bring it back to low consumption mode Refer to Fig 1 5 for the JP8 jumper position JP8 JP5 JP6 JP7 JP4 RS232 TTL ...

Страница 16: ...nnector pins are as follows Model no type Header S4B PH K S 90 JST Housing PHR 4 JST or equivalent PIN SIGNAL DESCRIPTION 1 GND Ground signal 2 GND Ground signal 3 Vin Head voltage 4 Vcc Logic supply voltage NOTE For the electrical specifications see Chapter 4 WARNING Respect the polarity of the power supply Fig 1 6 1 INSTALLATION AND USE 1 6 PLUS II User Manual ...

Страница 17: ...JP2 are closed the Centronics parallel interface is selected If JP1 and JP2 are open the TTL parallel interface is selected Refer to Fig 1 7 for the JP1 and JP2 jumpers position JP3 JUMPERS SELECTION VIN ON PIN 3 4 J3 JUMPERS SELECTION SIGNAL ON PIN 12 14 JUMPERS SELECTION INTERFACE JP4 JP5 JP6 FEED 12 ACK GND 14 LED JP1 JP2 JUMPERS SELECTION INTERFACE JP1 JP2 TTL CENTRONICS Fig 1 7 1 INSTALLATION...

Страница 18: ...gnals on the connector pins are as follows Model no type Header 90 Terminal block pitch 5 08mm Housing Terminal block AWG 20 14 PIN SIGNAL DESCRIPTION 1 GND Ground signal 2 Vin Logic supply voltage NOTE For the electrical specifications see Chapter 4 WARNING Respect the polarity of the power supply Fig 1 8 1 INSTALLATION AND USE 1 8 PLUS II User Manual ...

Страница 19: ...nnector as indicated SIGNAL OF PIN 12 JP5 SIGNAL OF PIN 14 JP6 FEED GND ACK LED Refer to Fig 1 9 for the JP5 and JP6 jumpers position JP3 JUMPERS SELECTION VIN ON PIN 3 4 J3 JUMPERS SELECTION SIGNAL ON PIN 12 14 JUMPERS SELECTION INTERFACE JP4 JP5 JP6 FEED 12 ACK GND 14 LED JP1 JP2 TTL CENTRONICS JUMPERS SELECTION SIGNAL ON PIN 12 14 JP5 JP6 FEED 12 ACK GND 14 LED Fig 1 9 1 INSTALLATION AND USE Us...

Страница 20: ...P C 32 5 HEAD VOLT V 5 00 Baud Rate 38400 bps Data Length 8 bits chr Parity None Handshaking Xon Xoff Autofeed CR Enabled Columns 24 col Print Mode Normal Char Mode Normal Print Density 0 PUSH key to enter setup FAST PUSH key to exit PRINTER SETUP HEAD TEMP C 32 5 HEAD VOLT V 5 00 Interface Centronics Autofeed CR Enabled Columns 24 col Print Mode Normal Char Mode Normal Print Density 0 PUSH key to...

Страница 21: ...ed with the symbol D are the default values 1 NOTE Only parallel interface model parameter 2 NOTE Only serial interface model parameter The settings made are stored in nonvolatile memory and are loaded automatically During power up if the FEED key is held down the printer enters the autotest routine and prints out the setup report The printer will remain in standby in Hexadecimal dump mode see par...

Страница 22: ... Place the paper roll making sure it unrolls in the proper direction as shown see Fig 1 14 Take out the paper and re close the cover as shown see Fig 1 15 The printer cover is locked Tear off the exceeding paper using the jagged edge see Fig 1 16 The printer is ready 1 2 3 4 5 Fig 1 13 Fig 1 14 Fig 1 16 Fig 1 15 1 INSTALLATION AND USE 1 12 PLUS II User Manual ...

Страница 23: ... Fig 1 17 using M3 tapping screws n 3 Fixing back Fix the printer in the 3 holes as shown in the scheme B see Fig 1 18 using 3 screws for plastic d 3 6 mm usable length A B NOTE The informations provided in this paragraph are corrects for all models Fig 1 17 Fig 1 18 1 INSTALLATION AND USE User Manual PLUS II 1 13 ...

Страница 24: ...A FIXING see Fig 1 19 Use only the 2 hooks provided in the package Place the printer on the panel Insert the 2 fixing hooks in their seat Push the 2 fixing hooks against the panel to lock the printer B REMOVING see Fig 1 20 Lift the flap by using a flat screwdriver Take away the hook Fig 1 19 Fig 1 20 1 INSTALLATION AND USE 1 14 PLUS II User Manual ...

Страница 25: ... connector pin signals Model no type Header Molex 53261 series 6 pin Housing Molex 51021 series 6 pin no 51021 0600 PIN SIGNAL IN OUT DESCRIPTION 1 DTR OUT Data terminal ready 2 TX OUT Data transmission 3 RX IN Data reception 4 GND Ground signal 5 FEED IN FEED signal active at low level 6 LED OUT LED signal external Fig 2 1 Tab 2 1 2 INTERFACES User Manual PLUS II 2 1 ...

Страница 26: ...n are TD RD and RTS if the RTS CTS protocol has been selected while if the XON XOFF protocol has been selected the signals are TD and RD Transmission format BIT 0 START BIT BIT 1 BIT 2 BIT 3 BIT 4 BIT 5 BIT 6 BIT 7 1 PARITY BIT 2 STOP BIT NEXT START BIT NOTE 1 Bit 7 is present if only in the printer set up is enabled 8 bit char as data length 2 Parity Bit is preset if only in the printer set up th...

Страница 27: ...XON XOFF Protocol DATA RD STOP START BIT START BIT STOP DATA WAIT 13XOFF TD STOP START BIT START BIT STOP 11XON 2 INTERFACES User Manual PLUS II 2 3 ...

Страница 28: ...e Header AMP MODU II no 280379 2 Housing AMP MODU II no 280360 PIN SIGNAL IN OUT DESCRIPTION 1 DTR OUT Data terminal ready 2 TX OUT Data transmission 3 RX IN Data reception 4 GND Ground signal 5 RESET IN Reset signal active at a low level 6 POWER ON IN Power On signal an impulse of at least 500 m sec active at a high level Fig 2 2 Tab 2 2 2 INTERFACES 2 4 PLUS II User Manual ...

Страница 29: ...low show a sample connection between printer and Personal Computer using a 6 pin fe male AMP MOUD II connector by printer side and a 9 pin female connector by a PC side DTR DTR TX RX GND RX TX GND Printer PC 2 INTERFACES User Manual PLUS II 2 5 ...

Страница 30: ...IN SIGNAL IN OUT DESCRIPTION 1 AD0 IN Data 0 2 AD1 IN Data 1 3 AD2 IN Data 2 4 AD3 IN Data 3 5 AD4 IN Data 4 6 AD5 IN Data 5 7 AD6 IN Data 6 8 AD7 IN Data 7 9 BUSY OUT Peripheral not ready to receive data 10 ERROR OUT Error 11 PAPER END OUT Paper end 12 ACK OUT Acknowledge Setting FEED 1 IN FEED signal active at low level with JP5 2 13 STROBE IN Strobe 14 GND Ground signal Setting LED OUT LED sign...

Страница 31: ...ale 1 2 AD0 AD0 STROBE AD1 AD1 AD2 AD2 AD3 AD3 AD4 AD4 AD5 AD5 AD6 AD6 AD7 AD7 BUSY ACK ERROR BUSY PAPER END PAPER END ACK or FEED 1 GND or LED ERROR GND GND GND GND GND GND GND GND GND GND Printer PC 5 4 3 2 1 6 7 9 8 10 11 12 13 14 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 21 23 24 25 STROBE JP5 2 JP6 2 NOTE 1 Signal not available with Centronics interface 2 For JP5 and JP6 settin...

Страница 32: ... data validity and BUSY indicate that the printer is ready to receive data Transmission format VALID DATA VALID DATA D0 D7 STROBE BUSY Flow diagram ERROR NO NO NO SI NO SI SI OUT DATA OUT STROBE 0 OUT STROBE 1 START RETURN TIMEOUT 1 sec TIMEOUT 4 sec BUSY 1 BUSY 0 2 INTERFACES 2 8 PLUS II User Manual ...

Страница 33: ...PIN SIGNAL IN OUT DESCRIPTION 1 AD0 IN Data 0 2 AD1 IN Data 1 3 AD2 IN Data 2 4 AD3 IN Data 3 5 AD4 IN Data 4 6 AD5 IN Data 5 7 AD6 IN Data 6 8 AD7 IN Data 7 9 BUSY OUT Peripheral not ready to receive data 10 ERROR OUT Error 11 PAPER END OUT Paper end 12 ACK OUT Acknowledge Setting FEED 1 IN FEED signal active at low level with JP5 2 13 STROBE IN Strobe 14 GND Ground signal Setting LED OUT LED sig...

Страница 34: ...le 1 2 AD0 AD0 STROBE AD1 AD1 AD2 AD2 AD3 AD3 AD4 AD4 AD5 AD5 AD6 AD6 AD7 AD7 BUSY ACK ERROR BUSY PAPER END PAPER END ACK or FEED 1 GND or LED ERROR GND GND GND GND GND GND GND GND GND GND Printer PC 5 4 3 2 1 6 7 9 8 10 11 12 13 14 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 21 23 24 25 STROBE JP5 2 JP6 2 NOTE 1 Signal not available with Centronics interface 2 For JP5 and JP6 setting...

Страница 35: ...3 2 1 ESC POS Emulation The following table lists all the commands for function management in ESC POS Emulation of the printer The commands can be transmitted to the printer at any moment but they will only be carried out when the commands ahead of them have been executed The commands are carried out when the circular buffer is free to do so COMMAND DESCRIPTION TABLE Com HEX Com ASCII Description ...

Страница 36: ...1B 69 ESC i Selects 40 columns 1B 6D ESC m Transmit print mode in serial 1B 71 ESC q Disable underlining 1B 73 ESC s Transmits next character in serial 1B 76 ESC v Transmits printer ID 1B FA n1 n2 ESC n1 n2 Prints graphic 1D 24 n GS n Set absolutes shift into a graphic line 1D 49 n GS I n Transmits the printer ID 1D 55 GS U Resets printer parameters to default value 1D 57 n d1 dn GS W n d1 dn Prin...

Страница 37: ...egin ning of the line Default Setting in option register by means of front keys Reference 00 02 03 04 1B 4D Example 02 Name Double height printing Format ASCII Hex 02 Decimal 2 Description The printer prints in double height format Notes The commands from 00 to 09 do not cancel the print buffer The commands which modify the direction of the characters are only active at the begin ning of the line ...

Страница 38: ...and executes a line feed of 24 dots 3 mm If the line buffer contains text the line feed is character height spacing dots default 4 mm Default Reference 0B Example n 0B Name Forward feeds n lines Format ASCII Hex 0B Decimal 11 Description Carries out the number of line feeds specified in n Notes The number must be ASCII and between 0 and 9 when n 0 the command is ignored This command clears the lin...

Страница 39: ...onds to 240 horizontal dots divided into 40 blocks of 6 dots each Notes To obtain graphic printing enter the command 11 at the beginning of each line The format of the byte in graphic configuration is X R P6 P5 P4 P3 P2 P1 D7 D6 D5 D4 D3 D2 D1 D0 where X is not used 0 is recommended R must be fixed at level 1 P1 P6 are the graphic dot data 1 prints 0 does not print The P6 bit of the string of dots...

Страница 40: ...SII S 0004 Name Switch off the printer Format ASCII ESC 0 Hex 1B 30 Decimal 27 48 Description Switch off the printer and bring it back to low consumption mode if was disabled the Auto POWER ON function see paragraph 1 3 3 Notes This command is executed only when the JP8 jumper is open Default Reference Example 1B 40 Name Resets the printer Format ASCII ESC Hex 1B 40 Decimal 27 64 Description Cance...

Страница 41: ... 68 Example dd 1B 4D Name Writes the value dd in the print mode Format ASCII dH dL ESC M Hex dH dL 1B 4D Decimal dH dL 27 77 Range dH 48 48 dL 51 Description Sets the print mode default parameters ASCII characters dd identify an hexadecimal byte as follow 00 small character printing 01 double width printing 02 double height printing 03 expanded printing Notes Default Setting in option register by ...

Страница 42: ...ame Prints a graphic line at 203 dpi Format ASCII ESC W Hex 1B 57 Decimal 27 87 Description After receiving this command the printer waits for 48 bytes which correspond to an entire graphic line In fact 48 bytes of 8 bits each correspond to 384 dots per line Notes Defaul Reference Example dd 1B 61 Name Selects the number of dot spaces Format ASCII dd ESC a Hex dd 1B 61 Decimal dd 27 97 Description...

Страница 43: ... of byte BIT 0 FUNCTION DESCRIPTION 0 Check digit is not printed Check digit 1 Check digit is printed BIT 1 FUNCTION DESCRIPTION Not used BIT 3 BIT 2 FUNCTION DESCRIPTION 0 0 None HRI Position 0 1 Above 1 0 Below 1 1 Above below BIT 5 BIT 4 FUNCTION DESCRIPTION 0 0 Normal Barcode width 0 1 Double 1 0 Triple 1 1 Not used BIT 6 FUNCTION DESCRIPTION Not used BIT 7 FUNCTION DESCRIPTION Not used length...

Страница 44: ...barcode type Code 39 50 barcode heigth 10 mm 3C starting position 7 5 mm 14 HRI printing below barcode width double 04 characters number to print PLUS characters to print 1B 68 Name Selects 42 columns Format ASCII ESC h Hex 1B 68 Decimal 27 104 Description On receiving this command the printer enters 42 column per line printing mode Notes Default Reference 1B 49 1B 69 Example 1B 69 Name Selects 40...

Страница 45: ...s on two bytes For example if you receive 30 32 it means that printing is in double height mode 1B 71 Name Disable underlined printing Format ASCII ESC q Hex 1B 71 Decimal 27 113 Description Disable underlined printing Notes Default Reference 1B 51 Example 1B 73 Name Transmits the next character in serial Format ASCII ESC s Hex 1B 73 Decimal 27 115 Description Transmits the next character it recei...

Страница 46: ... error 7 Off 00 0 Not used Fixed to Off Default Reference Example 1B FA n1 n2 Name Print graphic bank 384 x 85 dots Format ASCII ESC n1 n2 Hex 1B FA n1 n2 Decimal 27 250 n1 n2 Range 0 n1 n2 255 Description Prints the graphics bank from flash n1 specifies the starting dot line 1 85 n2 specifies the number of lines to print Notes If n1 n2 85 the printer only prints 85 n1 1 dotlines Default Reference...

Страница 47: ...er executing this command the printer is initialized Default Reference Example 1D 57 n d1 dn Name Prints n byte of a 200 dpi graphic line Format ASCII GS W n d1 dn Hex 1D 57 n d1 dn Decimal 29 87 n d1 dn Range 1 n 48 0 d1 dn 255 Description Print n byte of a 200 dpi graphic line where n specifies the number of byte to print d1 dn specify the bytes to print Notes If the bit image data input exceeds...

Страница 48: ...Blank page 3 PRINTER FUNCTIONS 3 14 PLUS II User Manual ...

Страница 49: ...go 384 x 85 dots Number of columns 24 40 Character matrix 16 x 24 8 x 24 Printing speed Lines sec 13 13 Chars sec 307 512 Characters L x H mm 2 x 3 1 x 3 PAPER SPECIFICATIONS Type of paper Thermal rolls heat sensitive side on outside of roll LINERLESS paper see paragraph 1 1 1 Paper width 57 mm 0 5 mm Recommended types of paper from 55 g m2 to 70 g m2 Internal roll core diameter 13 mm External rol...

Страница 50: ... Rh Storage temperature Humidity 20 C 70 C 10 90 Rh Dimensions Length mm 90 max Width mm 57 max Height mm 85 5 max Weight gr 141 1 NOTE 1 Referred without paper roll 2 Codes description PLUS II S Serial RS232 PLUS II T Serial TTL PLUS II S 0004 RS232 Extended range PLUS II C Parallel Centronics PLUS II P Parallel TTL PLUS II C 0004 Parallel Centronics Extended range 4 TECHNICAL SPECIFICATIONS 4 2 ...

Страница 51: ...kness N 3 THREADS M3 N 3 SCREWS ø3 FOR PLASTIC 81 5 70 5 35 11 111 57 1 8 43 2 45 90 24 1 14 6 10 1 18 4 13 1 10 4 Versions PLUS II C PLUS II C 0004 PLUS II P PLUS II S 0004 Versions PLUS II S PLUS II T Fig 4 1 4 2 DIMENSIONS 4 TECHNICAL SPECIFICATIONS User Manual PLUS II 4 3 ...

Страница 52: ...Blank page 4 TECHNICAL SPECIFICATIONS 4 4 PLUS II User Manual ...

Страница 53: ...5 1 CHARACTER SETS The printer has 2 fonts each width 224 characters Font 1 and Font 2 Shown below in figure 5 1 is an example of font1 Font 1 Fig 5 1 5 CHARACTERS SET User Manual PLUS II 5 1 ...

Страница 54: ...Blank page 5 CHARACTERS SET 5 2 PLUS II User Manual ...

Страница 55: ... 65 40 5 38 5 3 11 2 M3 4 M3 BOTTOM V V PE N L PPSPS 025 05 Switching power supply 5V 25W Input specifications Input voltage AC 85V 264V DC 120V 375V Current 0 8A max at 100V AC input Input frequency 47Hz 63Hz Output specifications Output voltage 5V Output current 5 0A Efficiency 72 Environmental conditions Operating temperature 25 C 70 C Humidity 20 85 Storage temperature Humidity 25 C 75 C 10 95...

Страница 56: ...aptor frame with hooks The kit is composed of N 2 Fixing hooks Adaptor frame 1 2 1 NOTE 1 Pay attention that the external frame the cover and the printer frame are made from polypropylene so it s better to keep away from Ammonia Methanol Acetone Washing up liquid Benzol Dishwasher liquid Hydrocarbon Dichloromethane Perchloretylene Ethylene Trichlorethylene Toluene 1 2 APPENDIX A ACCESSORIES AND SP...

Страница 57: ...ng slide of the frame with the smoothed corner D not the side with two hooks see Fig A 3 Fix the printer to the frame using the 2 hooks E included with the printer see Fig A 3 The printer frame unit is assembled Fit the printer frame unit F into the panel G and fix it using the 2 hooks H included in the assem bling kit see Fig A 4 APPENDIX A ACCESSORIES AND SPARE PARTS User Manual PLUS II A 3 ...

Страница 58: ... PANEL FIXING N 3 T H R E A D S M 3 119 113 0 5 113 0 5 46 5 MAX 17 4 90 112 26 3 111 39 5 10J Max Panel thickness MOUNTING SEAT IN THE PANNEL Fig A 5 Printer dimensions assembled with the frame APPENDIX A ACCESSORIES AND SPARE PARTS A 4 PLUS II User Manual ...

Страница 59: ...LUS The kit includes see Fig A 6 Power supply cable Data cable for serial interface 1 2 500mm To the cable connections proceed as follow Connect the power supply cable 1 to the power supply connector in the rear of the printer see Fig A 7 Connect the data serial interface cable 2 to the interface connector in the rear of the printer see Fig A 7 1 2 APPENDIX A ACCESSORIES AND SPARE PARTS User Manua...

Страница 60: ...can be supplied with a data serial cable see Fig A 8 PCSKPLUS 0004 Starter Kit for PCPLUS S 0004 500mm X 1 Connect the data serial interface cable 1 to the interface connector in the rear of the printer see Fig A 9 APPENDIX A ACCESSORIES AND SPARE PARTS A 6 PLUS II User Manual ...

Страница 61: ...P The kit includes see Fig A 10 Power supply cable Data cable for parallel interface 1 2 500mm To the cable connections proceed as follow Connect the power supply cable 1 to the power supply connector in the rear of the printer see Fig A 11 Connect the data parallel interface cable 2 to the interface connector in the rear of the printer see Fig A 11 1 2 APPENDIX A ACCESSORIES AND SPARE PARTS User ...

Страница 62: ...n be supplied with a data parallel cable see Fig A 12 PCSKPLUS C 0004 Starter Kit for PCPLUS C 0004 1 500mm Connect the data parallel interface cable 1 to the interface connector in the rear of the printer see Fig A 13 APPENDIX A ACCESSORIES AND SPARE PARTS A 8 PLUS II User Manual ...

Страница 63: ...achines purchased N machines 10 50 100 100 Quantities recommended 5 30 60 90 RCT57X50 18MM LL Linerless paper roll L 57 Di 18 De 50 Quantity recommended per n machines purchased N machines 10 50 100 100 Quantities recommended 5 30 60 90 APPENDIX A ACCESSORIES AND SPARE PARTS User Manual PLUS II A 9 ...

Страница 64: ...custom biz CUSTOM ENGINEERING SPA World Headquarters Via Berettine 2 43100 Fontevivo Tel 39 0521 680111 Fax 39 0521 610701 info custom biz www custom biz All rigths reserved Part Number DOME PLUSII Rev 1 00 ...

Отзывы: