PIM 417-O
PITOT-STATIC LEAK TESTER TYPE D51600
Issue 5
November 2009
Page 7
DESCRIPTION
1. INTRODUCTION
The Penny & Giles 'Micro Leak' Pitot-Static Leak Tester (PSLT) is a microprocessor-controlled system
which primarily generates pitot and static pressures in order to leak test air data equipment to ensure
leak rates are compliant with standards specified for it. The PSLT is also capable of providing
functional testing of pneumatic switches.
The PSLT (
Figure 2
) is a robust, battery-powered, portable instrument with state-of-the-art
microprocessor control, offering the following features:
A. Leak testing of aircraft pitot and static systems.
B. Functional checking of aircraft airspeed and altitude switches.
C. Normal/Rapid Rate Control.
D. Remote reprogramming/maintenance checking utilising secure Infra-Red (IR) communications
(Manufacturer Mode only).
Figure 2 'Micro Leak' Pitot-Static Leak Tester
The PSLT is user-friendly, being simple in operation, and its built-in microcontroller enables the unit to
function with minimal Operator intervention.
The PSLT comes complete in its own carrying case which is of rugged construction and which has
space to house accessories such as the hose, spare battery packs, a battery charger (if applicable),
and the operating manual.
2. GENERAL DESCRIPTION
The PSLT is of modular design to facilitate easy repair. It comprises the following main assemblies:
A. Case
B. Front Panel Assembly
C. Panel Electronic Circuit (PEC)
D. Battery Pack
E. Pneumatic Assembly.
Содержание D51600
Страница 1: ...PITOT STATIC LEAK TESTER TYPE D51600 Operation Calibration Manual PIM 417 O Issue 5 November 2009 ...
Страница 2: ......
Страница 11: ...PIM 417 O PITOT STATIC LEAK TESTER TYPE D51600 Issue 5 November 2009 Page 5 Figure 1 Micro Leal Case Assembly ...
Страница 12: ...PIM 417 O PITOT STATIC LEAK TESTER TYPE D51600 Issue 5 November 2009 Page 6 THIS PAGE IS INTENTIONALLY BLANK ...
Страница 16: ...PIM 417 O PITOT STATIC LEAK TESTER TYPE D51600 Issue 5 November 2009 Page 10 THIS PAGE IS INTENTIONALLY BLANK ...
Страница 36: ...PIM 417 O PITOT STATIC LEAK TESTER TYPE D51600 Issue 5 November 2009 Page 30 THIS PAGE IS INTENTIONALLY BLANK ...
Страница 37: ......
Страница 39: ......