![Curtiss-Wright AVDU-5006-05-01-OPS Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/curtiss-wright/avdu-5006-05-01-ops/avdu-5006-05-01-ops_operators-manual_2700329010.webp)
AVDU-5006-05-01-OPS
Page 10 of 22
OPS
Issue A
© 2012 Curtiss-Wright Controls
Page 10 of 22
CONT
-
CONT
+
ENH
SWAP
FRZ
RATIO
ZOOM
-
ZOOM
+
4.1.2 Lower right keys
CONTRAST BUTTONS
Using the CONTRAST buttons the operator can:
Adjust the contrast (gain) of each video input, independently.
Contrast levels are preserved into the AVDU-5006 internal memory
for quick use. Following the contrast adjustment, the “CONTRAST”
feedback is displayed for few seconds.
ENH button:
This button is not used any longer.
SWAP BUTTON
Using the SWAP button the operator can:
Swap the MAIN & DUAL pictures. When SWAP is operated, the FRZ
processing is preserved (MAIN/DUAL frozen picture becomes
respectively a DUAL/MAIN frozen picture). Following the SWAP
command, the “SWAP” feedback is displayed for few seconds.
FREEZE BUTTON
Using the FRZ button the operator can:
Freeze any MAIN HD, RGB, Y/C, COMP picture. DUAL picture is still
alive. Following the FRZ command, the “FREEZE” feedback is
displayed for few seconds. (The keys do not Flash).