15
Figure 6.6
Stem Retainer
Disc
Disc Holder
Figure 6.8
Stem Retainer
Disc Holder
Lock Screw
11. Remove the
Disc
[4] from the
Disc Holder
[6]
(Figure 6.6)
.
a. Hold the assembly and rotate the
Disc
[4] with the tip of your finger.
b. For o-ring seat type valves, refer to Appendix C for instructions.
12. To separate the
Disc Holder
[6] from the
Stem Retainer
[14], first
thread the lock screw up into the
Stem Retainer
[14] using the fixture
shown in
Figure 6.7
to hold the assembly.
a. Except for the D & E orifice bellows (A11) designs which have a one
piece stem retainer/disc holder, the
Stem Retainer
[14] and
Disc
Holder
[6] are held together with a
Disc Holder Lock Screw
[26].
b. The
Disc Holder Lock Screw
[26] has a hex socket requiring the
use of an Allen key
(Figure 6.8)
.
c. Locking tension is relieved by threading the lock screw UP INTO the
Stem Retainer
[14].
d. Allen key wrench sizes are shown in
Table 6.1
.
e. Be careful not to damage the guiding surface of the
Stem Retainer
[14] during disassembly.
f. For bellows valves see Appendix B.
13. Remove the
Blow Down Ring
[7] from the
Nozzle
[5].
14. Turn the valve
Body
[1] over and re-clamp to the work bench. With a
spanner wrench and mallet, remove the
Nozzle
[5] from the
Body
[1]
a. Some valves may use wrenching flats instead of spanner holes.
NOTES:
1.
For BalanSeal Bellows construction,
please see Appendix B for
disassembly instructions.
2.
For O-Ring seat construction,
please see Appendix C for disassembly
instructions.
3.
For open lever, packed lever and bolted cap construction,
please
see Appendix D for disassembly Instructions.
Allen Key Sizes
Disc Holder Lock Screw
Orifices
Allen Key Size
D thru J
3/16"
K thru P
7/32"
Q thru T
3/8"
Figure 6.7
Table 6.1
Содержание 2600 Series
Страница 1: ...0713T R0 Series 2600 Maintenance Manual ...
Страница 47: ...47 Notes ...