Your Curtis ADS System is Factory Pre-Set and Ready to Go… 

Right from the Carton.

Following are the Factory Settings for your GEMINI

®

Coffee Brewing System:

• Brew Temperature = 200°F
• Brew Volume = Set to dispensing vessel requirements (36 - 5 oz. Cups)
• Water Bypass = ON 
• Sleep Mode = OFF

Generally there will never be a reason to change your ADS programming.  However, should you need to
make slight adjustments to meet your brewing needs, programming instructions are 
provided later in this manual.

SYSTEM REQUIREMENTS

• Water Source

20 – 100PSI (Minimum Flow Rate of 1 GPM)

CAUTION: DO NOT connect this brewer to hot water. The inlet valve is not rated for hot water.

• Electrical

See attached schematic for your model

This equipment is to be installed to comply with the applicable federal, state, or local plumbing and 
electrical codes having jurisdiction.

SETUP STEPS

The unit should be level (left to right and front to back), located on a solid counter top.  Connect a water
line from the water filter to the brewer. NOTE: Some type of water filtration device must be used to main-
tain a trouble-free operation. (In areas with extremely hard water, we suggest that a sedimentary and
taste & odor filter be installed.) This will prolong the life of your brewing system and enhance coffee qual-
ity.  The top back panel of the brewer has two 8-32 x 3/8” screws to 
facilitate mounting the filter.

The National Sanitation Foundation requires the following water connection:

1. A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) so that the machine can be

moved for cleaning underneath.

2. In some areas an approved backflow prevention device may be required between the brewer and the water

supply. (Check local plumbing codes)

1. A 3/8” NPT x 3/8” compression elbow has been supplied for water line connection.  Use

tubing sized sufficiently to provide a minimum of 1.0 GPM.

2. Connect the unit to an appropriate electrical power circuit.
3. Turn on the toggle (STANDBY/ON) switch behind the unit. The heating tank will start to

fill.  When the water level in the tank rises to the correct volume, the heating elements

will energize automatically.  With ADS Systems there is no danger of element burnout

caused by an empty tank.

4. The heating tank will require 20 to 30 minutes to reach operating temperature (200°F)

as indicated by the READY-TO-BREW indicator.

5. Prior to brewing, dispense 12 ounces of hot water through the hot water faucet.
6. Run brew cycles of at least 12 ounces, per brew head, to purge the water lines of any

air that may be trapped after filling.

QUICK START &

SET-UP

WARNING: To avoid
electrical shock this
brewing system must
be properly ground-
ed.

IMPORTANT: Your
ADS System is
“PLUG and BREW”
Ready.  There is no
need to manually 
fill the water tank or
change the factory
program. 

Содержание GEM-12D

Страница 1: ...Revised Jan 2009 WILBUR CURTIS COMPANY MONTEBELLO CA USA MODELS INCLUDED GEM 12D Installation Instructions Service Warranty Information GEMINI DIGITAL COFFEE BREWING SYSTEMS ISO 9001 REGISTERED...

Страница 2: ...service personnel Keep hands and other items away from hot parts of the appliance during operation Never clean with scouring powders or abrasive cleaning tools CONVENTIONS WARNINGS TO HELP AVOID PERS...

Страница 3: ...protection during shipping Make sure the shipping carton is not damaged or punctured Unpack the carton carefully inspecting the contents for any damage that may have occurred in transit STANDARD ITEM...

Страница 4: ...of the brewer has two 8 32 x 3 8 screws to facilitate mounting the filter The National Sanitation Foundation requires the following water connection 1 A quick disconnect or additional coiled tubing at...

Страница 5: ...g will begin immediately If Recovery Light is ON Brew Light will blink and brewing will begin when the correct temperature is reached WARNING To avoid scalding do NOT remove brew cone while brew indic...

Страница 6: ...setting has bypass open Bypass use should always be determined BEFORE setting Brew Volume INCREASING DECREASING BYPASS FLOW The 36 cup brew cycle has a factory set Bypass of approximately 35 To chang...

Страница 7: ...ess ON OFF BREW BREW BREW READY TO BREW READY TO BREW STEPS TO PROGRAMMING WARNING These steps will involve working with hot water Scalding may occur if care is not taken against spilling TEMPERATURE...

Страница 8: ...ched the brew cycle will automatically start Recovery is indicated by a yellow light on the membrane In a few minutes the tank will reach brew temperature setting as indicated by the READY TO BREW lig...

Страница 9: ...the corresponding warmer light will blink advising you coffee should be replaced Once the alarm sounds you can shut it off by pressing the WARMER button The Quality Timer can be set from DISABLED zero...

Страница 10: ...ean it once a week 4 Periodic De Liming of Heat Tank may be necessary especially in areas with especially hard water Excessive Lime buildup in heat tank may void warranty CLEANING A daily routine of c...

Страница 11: ...nded for terminal connections at proper operation Check for loose connections at the control board or tank terminals 10 Defective Control Board Contact Factory Symptom Water in HeatING Tank does NOT g...

Страница 12: ...r Contact Factory 20 Defective Triac Contact Factory 21 Defective Control Board Contact Factory HIGH TEMP THERMOSTAT HIGH TEMPERATURE RESET THERMOSTAT The High Temperature Reset Thermostat protects th...

Страница 13: ...8 cm 14 25 36 3 cm 16 25 41 2 cm 18 25 46 3 cm 7 00 17 8 cm 5 50 14 1 cm 20 000 50 8 cm 5 75 14 5 cm 3 75 9 4 cm 16 50 41 9 cm 1 00 2 5 cm 4 00 10 2 cm THIS DIMENSION CAN BE INCREASED BY 1 WITH ADJUST...

Страница 14: ...14 ELECTRICAL SCHEMATICS...

Страница 15: ...15 ELECTRICAL SCHEMATICS...

Страница 16: ...16 PARTS DIAGRAMS GEM 12D 12 11 14 15 1 9 10 16 2 5 3 6 6A 8 7 4 25 24 30 31 32 26 29 27 28 18 20 17 19 21 22 23 13 22 F...

Страница 17: ...G 4 ADJUSTABLE 3 8 16 THRD ITALIAN STYLE LABEL BOTTOM PANEL HEAT SINK 1PH GEM COVER FRONT GEM 12D FUSE HOLDER ASSY W 5A FUSE SWITCH TOGGLE LABEL MEMBRANE CONTROL PANEL GEM 12D CONTROL BOARD VALVE INLE...

Страница 18: ...GEM3 LID SATELLITE STAINLESS OLDER UNITS GAUGE GLASS ASSEMBLY 8 WASHER SHIELD CAP 1 8 SHIELD 8 INCH GAUGE GLASS GAUGE GLASS 8 INCH WASHER SHIELD BASE 3 16 FAUCET S NON LOCKING FAUCET ESP BLACK NON LO...

Страница 19: ...19...

Страница 20: ...upplied with this equipment 4 Improper water supply This includes but is not limited to excessive or low water pressure and inadequate or fluctuating water flow rate 5 Adjustments and cleaning The res...

Отзывы: