ERROR CODES
EC1
Warning Messages - Allows Brewer to Continue Brewing
MESSAGE DISPLAY
WARNING DESCRIPTION
CAUSE
Maintenance Required
Maintenance Required
Brew count “Gallons Since Reset” exceeds programmed
preventative maintenance period.
Low Water Flow
Warning
Low Water Flow
If the Inlet valve remains on longer than XX seconds (during the
brew cycle only) and repeats TWICE during that brew cycle. It shall
FOHDUXSRQWKHQH[WEUHZDQGLIWKHVDPHORZÁRZH[LVWVDJDLQLW
will re-appear. XX = Alpha 20 secs; Gem/TP Twin 40 secs; Gem/TP
Single 30 secs.
Internal Error 2
UPM-UCM have a mismatch
in their settings.
8308&0KDYHDPLVPDWFKLQWKHLUVHWWLQJVÀUPZDUHXSGDWH
needed.
Error Messages - Brewer Will Stop Brewing
MESSAGE DISPLAY
ERROR DESCRIPTION
CAUSE
Water Level Error
)LOOUXQHUURU2YHUÁRZ
The water inlet valve has either been open for more than 10 minutes
RQWKHLQLWLDOWDQNÀOORUKDVEHHQRSHQIRUVHFRQGVRQODUJH
EUHZHUVDQGVHFRQGVRQ&*&WHDEUHZHUVLQQRUPDORSHUDWLRQ
Sensor Error
Open Sensor
Break in the temperature thermistor circuit or short circuit.
Over Temp. Error*
Excess Temperature
The sensor is reading that temperature in the heating tank has risen
DERYH)RUVHQVRUKDVVKRUWHGWRJURXQG
Internal Error 1
UPM-UCM Communication
Break in the UPM-UCM communication circuit.
* This error is disabled on CGC and Seraphim
®
models.
(&3303$0%&4ø
$