After each application of formulation the system must be flushed to protect the
equipment from the corrosive material in the formulation.
To Flush System:
·
With the engine and blower operating, place the lever of the 3-Way valve into
the “FLUSH” position
·
Place “SPRAY” toggle switch on remote control box into the “ON” position.
·
Flush for 3 to 5 minutes.
3-WAY VALVE WORKING IN “FLUSH” POSITION
In above diagram the 3-Way valve is working to dispense Flush solution (valve lever
pointing up). Upon the activation of the “Spray” button at the remote control box, the
diaphragm pump will draw liquid from the flush tank and pass through the flush filter,
3-way valve and pump “IN” port.
CAUTION
Never handle any parts on the machine that come in contact with formulation until
the unit has been thoroughly flushed with Isopropyl Alcohol or other recommended
flushing agent.
29