FORMULATION FILTER
The system is equipped with an in line low profile filter located at the formulation
tank standpipe. This filter is to prevent any foreign matter from entering the Pump,
solenoid valve and the nozzle system. Located inside the filter housing is a fine
mesh stainless steel screen and an Aflas gasket seal.
IN-LINE FILTER (P/N 62558-5)
TO REMOVE AND CLEAN THE SCREEN
1.
Loosen and remove the bottom portion (bowl) from the housing body, being
careful not to lose the Aflas gasket seal ring.
2.
Remove and clean the fine wire mesh stainless steel screen.
3.
Check the Aflas gasket seal ring and replace if necessary.
CAUTION
Do not over tighten as damage the Aflas gasket seal ring may occur. Over tighten
will not improve the seal.
NOTE:
If leakage occurs, open the unit and clean and inspect the Aflas gasket
seal ring. A suitable lubricant applied to the ring will help the seal.
24