background image

CONTENTS

1. MODEL ENCODEMENT ............................ page 1

2. TECHNICAL SPECIFICATIONS.................. page 1

3. INSTALLATION ............................................ page 7

4. OPERATION .................................................. page 8

5. TROUBLESHOOTING ................................ page 9

6.  MAINTENANCE ..........................................page 10

Curtis 1620 Manual

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

Read the Operating Instructions carefully before using the Model 1620 charger.

1. 

WARNING

– Failure to install and operate the charger in accordance with these instructions may result 

in damage to the charger or injury to the operator. 

2. 

WARNING

– Never place the charger directly above or below the battery being charged. Gases or fluids 

from the battery will corrode and damage the charger. Locate the charger as far away from the battery 
as the output cable allows.

3. 

WARNING

– Explosive gases may result from charging. Provide adequate ventilation during charging. 

Prevent flames or sparks.

4. 

WARNING

– Do not attempt to open the charger. There is risk of electric shock even if the charger is 

unplugged. No user serviceable components inside.

5. 

WARNING

– If safe operation of the charger can no longer be ensured, stop and secure it against 

operation.

6. 

WARNING

– If the supply cord is damaged, it must be replaced by a qualified person in order to avoid 

hazard.

7. 

WARNING

– Never charge a frozen battery.

8. 

WARNING

– To reduce the risk of injury, charge only lead acid or gel cell type batteries. Do not attempt 

to charge any other type of chargeable or non-rechargeable battery; these batteries may burst, causing
personal injury and damage.

9. 

WARNING

– To protect the operator from serious injury and the battery from damage, Curtis recommends

using a fast blow fuse rated for a minimum of 32V and a maximum of 30A between the battery and the 
charger.

10. 

CAUTION

– It is recommended that you disconnect the AC power cord before connecting or disconnecting 

the charger to the battery.

11. 

CAUTION

– Not intended for outdoor use.

12. 

CAUTION

– Charger surface may be hot while plugged in and for a period of time thereafter. 

13. 

CAUTION

– Units with fans must have at least 30mm of clearance on the vented ends of the charger. 

Do not restrict ventilation to the charger in any way. Failure to do so may result in degradation of charge 
performance.

14. 

CAUTION

– If charger failure or malfunction may cause personal injury or material damage, use

additional safety measures such as limit switches, guards, etc.

15. 

CAUTION

– Failure to install and use the charger in accordance with these instructions may impair the 

protection provided by the charger and may void the manufacturers warranty.

16. 

CAUTION

– Failure to install and use the charger in accordance with these instructions may impair the 

protection provided by the charger and may void the manufacturers warranty.

17. 

CAUTION

– Never plug a 120VAC only charger into a receptacle not rated for 120VAC nominal.

18. These chargers are suitable for use with all 24V, 12 cell, rechargeable lead acid/gel cell batteries ONLY.

It is intended for use with batteries rated up to 200 amp-hours.

19. This charger was manufactured and tested according to the applicable technical standards referenced 

herein. It complies with safety regulations as shipped from the factory.

20. Be sure to read and understand all of the battery manufacturer's instructions, such as removing or not 

removing cell caps or recommended rate of charging, prior to using this charger.

Warranty

Two Year Limited Warranty (see terms of sale for specifics).

All specifications subject to change without notice.

Содержание 1620

Страница 1: ...registered trademark of Curtis Instruments Inc M MA AN NU UA AL L MODEL 1620 S W I T C H M O D E BATTERY CHARGER Before charging read instructions carefully Applicable to 230VAC units only CURTIS INSTRUMENTS INC 200 Kisco Avenue Mt Kisco NY 10549 Tel 914 666 2971 FAX 914 666 2188 www curtisinst com ...

Страница 2: ... 32V and a maximum of 30A between the battery and the charger 10 CAUTION It is recommended that you disconnect the AC power cord before connecting or disconnecting the charger to the battery 11 CAUTION Not intended for outdoor use 12 CAUTION Charger surface may be hot while plugged in and for a period of time thereafter 13 CAUTION Units with fans must have at least 30mm of clearance on the vented ...

Страница 3: ... programmer only Pin Function 1 Rx 2 SEC_RTN 3 Tx 4 12V Motor Controller Inhibit Molex 39 01 4030 Capable of sinking up to 60mA DC to ground Pin Function 1 See wiring diagram 2 No connection 3 See wiring diagram DC Power Output 2 x M5 studs Pin Function B output B output Curtis 1620 Manual page 1 1 2 1620uv www xx yy zzz 1620 u v www xx yy zzz Model Cooling Sealing Input Output Output Series Volta...

Страница 4: ...possibilities occur charging will stop and the 1620 will set itself to Off Mode the charger remains in standby until restart voltage Vrst is reached Curtis 1620 Manual page 4 2 7 1 End of Charge Mode Figure 1 Charge profile for End of Charge Mode Figure 1 defines the charge profile for the End of Charge Mode As long as the battery voltage V is above Undervoltage Lockout Level Vuvlo charging will s...

Страница 5: ...nter standby mode The charger will continue this cycle of standby reactivation until power is removed or until the Model 1311 programmer is connected Curtis 1620 Manual page 5 2 7 4 Equalize Mode after Float Mode Figure 4 Charge profile for Equalize Mode after Float Mode Only flooded lead acid FLA batteries require equalization In order to prevent dam age to the battery the charger will go through...

Страница 6: ...he programmer to the 4 pin Molex connector between the indicators The yellow and green indicators will blink on and off simultaneously indicating that the charger is in programming mode 4 3 2 Configure the programmable parameters defined in Section 4 2 4 3 3 Once the programmable parameters have been defined disconnect the 1311 programmer from the charger The charger will reset and resume normal o...

Страница 7: ...y be damaged or old Replace battery Yellow blinks 2 twice Not reaching Vlv Battery manufacturer s rated capacity may 2 seconds off repeats within Tlv exceed charger s rating Increase Tlv decrease Green off Vlv increase Ilv or reset the charger 3 Battery may be damaged or old Replace battery No indicators on No power or Charger may be unplugged Check for damaged charger AC power Charger may be dama...

Страница 8: ...qualize the batteries End of charge soft overvoltage Veoc 29 35V 31VDC 0 1V 1 Charger goes into soft overvoltage mode from which it recovers when battery voltage drops below Vrst EoC Threshold Icv 2 20A 4A 0 5A 3 Current at which the charger transitions to EoC mode Restart Voltage Vrst 22 28v 26VDC 0 1V 1 Used when EoC Mode is EQUALIZE or OFF the battery voltage at which charger automatically turn...