6
7
2. TECHNICAL SPECIFICATIONS
2.1 Electrical Operating Voltage:
Operating Range:
±25% of nominal voltage.
Operating current
at pin 7 (V+) or 8 (V++) for each
nominal and maximum voltage is specified:
Rating
V+/V++
Test Conditions
V+ or V++ (Volts)
Operating Current (mA)
Notes
Nominal
Maximum
12
V+
12
(Nom)
17
—
For all test
conditions:
• V(Nom) is
the rated
value, e.g.
24 volts
• V (Max) =
V (Nom)
+25%
• J relay
15
(Max)
—
29
24/36
V+
24
26
—
30
—
39
V++
36
17
—
45
—
23
36/48
V+
36
22
—
45
—
30
V++
48
16
—
60
—
22
Rating
V+/V++
Test Conditions
V+ or V++ (Volts)
Operating Current (mA)
Notes
Nominal
Maximum
24/48
V+
24
26
—
For all test
conditions:
• V(Nom) is
the rated
value, e.g.
24 volts
• V (Max) =
V (Nom)
+25%
• J relay
30
—
39
V++
48
15
—
60
—
21
72/80
V+
72
22
—
90
—
28
V++
80
15
—
96
—
20
96
V+
96
21
—
120
—
27