3.1
CHARGING THE BATTERY (CONT'D)
D. Charge 12 volt battery at 30
-40
amps
until the acid temperature is above 8
0
o
F (26
o
C), and the hydrometer readi ng is 1.25
0
or higher. Acid
temperature must never
exceed 125
o
F while charging.
NOTE:
Both temperature and hydrometer readings must be met.
E. After charging the battery, check acid levels in all cells and fill each cell with acid to
the proper level.
F. Re-install vented caps.
G
. Re-install the battery onto the machine. Po
sition battery in the battery box so that
the terminal side of the battery is facing the engine.
H
. Connect the RED positive (+
) cable to the
positive terminal of the battery and fasten
it securely with the hardware provided.
I. Connect the BLACK
negative (-) cable to
the negative terminal of the battery and
fasten it securely with the hardware provided.
CAUTION
When installing the battery, connect the negative (-) cable last to prevent sparking
and shorting. When disconnecting is required, remove the negative (-) cable first.
Reverse polarity can cause damage to the starting and charging system.