To connect the cable to the appliance, remove the RH side
panel of the oven, let the cable through the cable gland
provided and connect it to the terminal block correctly.
The following pages show the electrical diagrams: please
refer to the one of the specific model to connect.
For a correct electrical connection, the appliance must:
• be included in an
equipotential system
in compliance
with the legislation in force. This connection must be made
between the various devices with the terminal marked
with the equipotential symbol
. The cable must have a
maximum cross-section of 10 mm2 (in compliance with IEC
EN 60335-2-42:2003-09) and must be yellow-green;
• must be
grounded
to the mains (green-yellow wire);
• must be connected to a
thermal differential switch
in
compliance with the regulations in force (0.03A A type);
• must be connected to an
omnipolar circuit breaker
allowing complete disconnection in overvoltage III category
conditions.
The Manufacturer accepts no liability for failure to comply with
the above.
The cable must be replaced by Cuppone or by its
technical assistance service, or in all cases by a person
with a similar role in order to prevent any risks.