3
Ed. 0221 - 70702730 REV03 Donatello hood - Pre-installation - Installation
Kg
Max 35°C
Max 70%
Min 5°C
Max 95°F
Min 41°F
min. 600 mm.
24 in.
Ø150 mm
Ø5,91 in.
fig.2.
fig.1.
1
CHeCKs BefOre PurCHasINg
Before purchasing the hood and before installing it, check the
following conditions, necessary for the correct installation,
operation and maintenance of the hood.
A Transport (Owner’s inspection)
√
Make sure that, on the day when you receive the hood
or it is installed:
• lifting equipment is available that can handle the
appliance safely (check weight and dimensions in the
following pages), together with staff qualified to carry
out this operation;
• personal protection equipment is available (e.g. safety
shoes, gloves, etc.)
B Installation room (Owner’s inspection)
√
Make sure that:
• the floor of the installation room is fireproof, perfectly
flat and capable of withstanding the weight of the
hood and underlying oven.
• the installation room:
• is dedicated and suitable to cooking food;
• has adequate air ventilation;
• complies with the current regulations on health
and safety and systems in the workplace;
• is protected from the weather;
• has a maximum temperature of b5° (41°f)
and +35°C (95°f);
• has a maximum humidity of 70%.
• between the hood and the ceiling there is a distance
of about
600 mm [24 in.]
(shorter distances could
damage ceilings made of particularly delicate and
heat sensitive materials - e.g. wood)
• there is adequate ventilation according to the regula-
tions in force in the Country of installation. If this is not
the case, a ø14 cm [Ø5.51 in.] air intake is mandatory,
communicating with the outside or a ventilated room
(i.e. storeroom, attic, garage, basement).
When choosing the positioning room, take into account
that the appliance must be easy
to move
for any extraor-
dinary maintenance: be careful that any brickwork after
installation (e.g.: wall construction, replacement of a door with a
narrower one, renovations, etc.) do not hamper movements.
C Electrical connection (qualified electrician’s
inspection)
The equipment is supplied with the power cord already
installed that must be connected to the electrical panel of
the Donatello oven.
evacuation tube, 150 mm
[Ø5,91 in.]
in diameter (NOT supplied)
Содержание Donatello KDN 435
Страница 1: ...Donatello HOOD Pre installation and installation manual KDN 435 KDN 635 KDN 635L KDN 935 ...
Страница 8: ...8 Donatello KDN 435 hood technical data hood single oven ...
Страница 10: ...10 Donatello KDN 435 hood technical data hood triple oven ...
Страница 12: ...12 Donatello KDN 635 hood technical data hood double oven ...
Страница 14: ...14 Donatello KDN 635L hood technical data hood single oven ...
Страница 16: ...16 Donatello KDN 635L hood technical data hood triple oven ...
Страница 18: ...18 Donatello KDN 935 hood technical data hood double oven ...
Страница 27: ...27 Ed 0221 70702730 REV03 Donatello hood Pre installation Installation Notes ...