F3005 - mini NEB

Rif Code 

Description

0010011 

Electric motor

0060028 

Capacitor 4 µF, 470 V

0060205 

Terminal block

0060287 

Locknut PG9

0060310 

Cable gland PG9

0070086 

PCB terminal board

0070103 

Level sensor

8  0080051 Gasket

0080333 

Atomizing disk

10  0080336 

Suction cone

11  0080337 

Suction cone o-ring

12  0080347 

Junction box o-ring

13  0080348 

Electric motor bracket

14  0080349 

Air diffuser

15  0080356 

Air filter

16  0080436 

Drain elbow

17 0080437  Siphon
18  0080438 

Drain pipe

19  0080447 

O-ring ø12 internal

20  0090154 

Breather pipe

21  0090969 

Solenoid valve with flow control

22  0090981 

Inlet hose

23  0090982 

Outlet hose

24  0091115 

Basin assembly

25  0091135 

Main body assembly

26  0091136 

Junction box assembly

27  0091137 

Electric motor cover assembly

28  0091143 

Solenoid valve cable

29  A020066 

Wall bracket

30  A020070 

Air filter grid

31  A020071 

Junction box cover

Содержание mini NEB F3005

Страница 1: ...F3005 mini NEB READ AND SAVE THESE INSTRUCTIONS Adiabatic humidifier ...

Страница 2: ......

Страница 3: ... o ring 13 0080348 Electric motor bracket 14 0080349 Air diffuser 15 0080356 Air filter 16 0080436 Drain elbow 17 0080437 Siphon 18 0080438 Drain pipe 19 0080447 O ring ø12 internal 20 0090154 Breather pipe 21 0090969 Solenoid valve with flow control 22 0090981 Inlet hose 23 0090982 Outlet hose 24 0091115 Basin assembly 25 0091135 Main body assembly 26 0091136 Junction box assembly 27 0091137 Elec...

Страница 4: ...allation 8 4 Startup control turn off 9 4 1 Checks 9 4 2 Start up 9 4 3 Turn off 9 5 Maintenance 9 5 1 Introduction 9 5 2 Inspection and cleaning of the water feed solenoid valve 9 5 3 Air filter cleaning 10 5 4 Basic cleaning of the drain 10 5 5 Advanced cleaning to be performed as needed or monthly 10 5 6 Cleaning of the cone and the disk 11 6 Storage 12 6 1 General notes 12 6 2 Checklist to be ...

Страница 5: ...ules Before installing the unit OR performing any maintenance or inspection of the unit be sure it is disconnected from the power supply Read all instructions before operating humidifier Keep humidifier free from obstructions to allow unit to function properly The humidifier must be connected to an electrical supply that complies with local regulations It is strongly recom mended to plug the humid...

Страница 6: ...t the minimal distance to allow proper air flow and dispersion of humidity Any other positioning or shortened distances may compromise the performance of the humidifier 3 2 1 Minimal distances Pic 3 Positioning A B C D Minimal ft 6 6 1 6 1 6 2 6 Suggested ft 9 8 3 3 4 9 4 9 Tab 4 Minimal distances 3 3 Electrical connections 3 3 1 Electrical wiring diagram Pic 4 F3005 Wiring diagram 1 Humidifier mo...

Страница 7: ...nd one for drain ing drain hose Both are included with your humidifier 3 4 1 Water Supply Hose The water supply hose has 3 4 diameter fittings at both ends Connect the end that is L shaped to the male fitting at the rear of the humidifier Tighten firmly and plumber s tape can be used to reduce any leaking The other end should be connected to your water supply which should also have a 3 4 male fitt...

Страница 8: ...allation is confirmed to be solid and secure tighten four screws attaching bracket to rear of humidifier IMPORTANT Observe minimal distances in Par 3 2 when wall mounting the Cuoghi Mini NEB Make sure bracket is completely horizontal before drilling holes Be certain the wall is able to sustain the weight of the humidifier 10 9 lbs If drilling through drywall it is highly recommended to screw into ...

Страница 9: ...er the humidistat to OPEN the main switch at the H H terminals The humidifier will slow down and the water inside the unit will fall back down to the water basin and trigger the siphon where it will be discharged through the drain hose IMPORTANT After shutting down the humidifier wait at least 30 seconds to allow the waste water to be completely discharged otherwise the siphon may not completely c...

Страница 10: ... filter Clean the air filter media first by vacuuming then by rinsing upside down with water and a household detergent Let the air filter media dry naturally do not ring or squeeze it Reassemble all of the pieces carefully checking that the air filter media is correctly positioned in the plastic assembly and then re tighten down with screws Air filter media must be completely dry before reinstalla...

Страница 11: ...bs release and the cone eases out The black gasket Or of the cone remains on the bottom of the disk gently pry it out and check that it is not damaged If it s compromised it must be replaced Remove the screw S and the disk D Clean the cone and the disk remove any dirt that can reduce or stop the passage of the water Pic 17 The cone and its gasket To assemble the cone follow carefully the following...

Страница 12: ...CAUSES SOLUTIONS The power supply is interrupted Check the electrical connections start ing from the electrical control box to the internal box of the humidifier The start capacitor is burned Substitute the capacitor with a new one 7 2 Air comes out from the air outlet but not nebulized water POSSIBLE CAUSES SOLUTIONS Water does not arrive to the basin Check that the water supply tap is opened Che...

Страница 13: ......