12
M869-4_GB_letter
mini NEB
ENGLISH
6 Storage
6.1 General notes
»
Store the machine in a room with a temperature between
»
14 °F and 140 °F.
»
When the machine is stored in the box, keep the box vertical
and upright.
»
Do not stack other boxes on top.
6.2 Checklist to be made before storing unit
and then resuming service
6.2.1 Before putting unit into storage
»
Disconnect all electrical connections and shut off water feed.
»
Cover the machine to protect it from dust. Th e original box
works well for this.
6.2.2 Resuming Service
»
Check the air fi lter and clean it if necessary.
»
Check that the fl oat is working correctly, gently slide it up
and down, seeing if there is any debris to cause resistance
and check that the fan and disk assembly rotates freely.
»
Open the water supply tap.
»
Check that all electrical connections are connected safely per
the instructions.
7 Problems and solutions
7.1 Th e humidifi er doesn’t start
POSSIBLE CAUSES
SOLUTIONS
Th e power supply is interrupted
Check the electrical connections, start-
ing from the electrical control box to
the internal box of the humidifi er
Th e start capacitor is burned
Substitute the capacitor with a new one
7.2 Air comes out from the air outlet but not
nebulized water
POSSIBLE CAUSES
SOLUTIONS
Water does not arrive to the basin
Check that the water supply tap is
opened. Check that the water feed
solenoid valve fi lter is not obstructed,
and that the hoses are correctly fi tted
and unobstructed. Finally, check that
the fl oating switch inside the basin is
free to move correctly.
Th e fan cone extremity is obstructed
Clean the cone from the impurities and
dirt inside.
7.3 Th e Humidifi er continuously discharging
water
POSSIBLE CAUSES
SOLUTIONS
Th e siphon is dirty
When dirt accumulates inside the
siphon, it is possible that the siphon
is triggered during normal operation.
Disassemble and clean the siphon
completely (see: par. 5.3 Inspection and
Cleaning of the Discharge Siphon)
Th e machine is installed not vertically
Check that the machine is installed as
described on par.3.2 Positioning.